Lies die bedienungsanleitung für Adastra AT6 (4 Seiten) kostenlos online; sie gehört zur Kategorie Lautsprecher. Dieses Handbuch wurde von 29 Personen als hilfreich bewertet und erhielt im Schnitt 4.8 Sterne aus 15 Bewertungen. Hast du eine Frage zu Adastra AT6 oder möchtest du andere Nutzer dieses Produkts befragen? Stelle eine Frage
Seite 1/4

AT6
6-Zone 100V Attenuator & Source Selector
Item ref: 2.476 95 UK
User Manual
Version 1.0
Caution: Please read this manual carefully before operating
Damage caused by misuse is not covered by the warranty

952.476UK User Manual
Introduction
Thank you for choosing the Adastra AT6 attenuator and source selector as part of your public address system.
This unit is designed to offer a completely passive zone control ution for installed 100V public address systems. sol
Please read this manual to gain the best results from your product and avoid damage through misuse.
SAFETY SYMBOL AND MESSAGE CONVENTIONS
CAUTION
RISK OF ELECTRIC SHOCK
DO NOT OPEN
AVIS
RISQUE DE CHOC
ELECTRIQUE NE PAS
OUVRIR
This symbol indicates that dangerous voltage constituting a risk of
electric shock is present within this unit
This symbol indicates that there are important operating and
maintenance instructions in the literature accompanying this unit.
Important not e: ic
The AT6 is designed for 100V speaker systems and is not suitable for low impedance 4/8/16 speakers. Ω
Although not mains powered, the 100V rating of this product requires standar high voltage precautions to be observed. d
Take care when making connections to avoid any shorted wires, which could cause damage to the amplifiers or the AT6.
Each output of the AT6 has a maximum power rating of 30W. Ensure that the combined tapped power of speakers
connected to a single output do not exceed 30W. es
Safety
• If liquids are spilled on the casing, stop using the AT6 immediately, allow the unit to dry out and have checked by
qualified personnel before further use.
• Avoid impact, extreme pressure or heavy vibration to the case
• No user serviceable parts inside Do not open the case refer all servicing to qualified service personnel. – –
• Use double insulated speaker wire with adequate current rating for the 100V speaker connections
Placement
• Keep out of direct sunlight and away from heat sources
• Keep away from damp or dusty environments
• Ensure adequate access to controls and connections
Cleaning
• Use a soft cloth with a neutral detergent to clean the casing as required
• Do not use strong solvents for cleaning the unit
Installation
The AT6 may be installed into a standard 1U rack space in a 19 rack cabinet. ”
Alternatively, the AT6 may be used free-standing.
Ensure adequate support for the unit and access connectors, terminals and controls. to
Do not place heavy objects on top of the AT6 that may cause excessive strain on the housing.

952.476UK User Manual
Front panel
1.
Zone volume rotary switch controls
2.
Source select (amplifier A / amplifier B)
3.
Zone on/off switch
Rear panel
4.
Zone output 6 screw terminals - + /
9.
Zone output 1 screw terminals - + /
5.
Zone output 5 screw terminals + / -
1 0.
Amplifier input B screw terminals + / -
6.
Zone output 4 screw terminals - + /
11.
24V emergency mute screw terminals + / -
7.
Zone output 3 screw terminals - + /
12.
Amplifier input A screw terminals - + /
8.
Zone output 2 screw terminals + / -
Connection and setup
Connections for the AT6 are all on the rear panel and the screw terminals are on removable blocks
for ease of installation. Ensure all connection polarities are correct as indicated on the rear panel.
The AT6 can operate in conjunction with one or two 100V amplifiers as input sources.
Connect the 100V output terminal from amplifier to the + terminal of IN A on the AT6 (12) an “ ”
Connect the COM output terminal from the same amplifier to the - terminal of IN A on the AT6. “ ”
If another amplifier is to be used as a second source, repeat the above steps for IN B terminals (10).
Between the terminals for IN A and IN B are another pair of screw terminals labelled EMG 24V (11) “ ”
These may be connected to the 24V trigger of an emergency panel to mute all outputs upon alarm.
Take maximum care not to allow any shorted strands of wire across any of the terminals.
All 100V speaker outputs are via screw terminals on 2 further removable blocks (4 –9)
Connect 100V speakers via the corresponding + and - output terminals on the AT6 “ ” “ ”
If more than 1 speaker is to be connected to a single zone output, connect these in parallel.
Ensure that the total load of all speakers on a single output does not exceed 30W.
Make sure all screw terminal blocks are firmly in place on the rear panel after making connections.
Produktspezifikationen
Marke: | Adastra |
Kategorie: | Lautsprecher |
Modell: | AT6 |
Breite: | 482 mm |
Tiefe: | 160 mm |
Gewicht: | 2390 g |
Produktfarbe: | Schwarz |
Impedanz: | - Ohm |
Höhe: | 43 mm |
Stecker: | IN A + B, OUT 1-6, 24V MUTE (Euroblock screw terminals) |
Verpackungsbreite: | 470 mm |
Verpackungstiefe: | 190 mm |
Verpackungshöhe: | 90 mm |
Paketgewicht: | 2600 g |
Frequenzbereich: | - GHz |
Maximale Eingangsleistung: | 30 W |
Brauchst du Hilfe?
Wenn Sie Hilfe mit Adastra AT6 benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten
Bedienungsanleitung Lautsprecher Adastra
16 August 2024
16 August 2024
15 August 2024
15 August 2024
13 August 2024
13 August 2024
13 August 2024
13 August 2024
13 August 2024
13 August 2024
Bedienungsanleitung Lautsprecher
- Majestic
- Beale
- Crosley
- Monster
- Medeli
- Logitech
- Legrand
- V7
- One Acoustics
- Audyssey
- Woxter
- Alecto
- Speco Technologies
- Camry
- Hercules
Neueste Bedienungsanleitung für -Kategorien-
17 Juni 2025
17 Juni 2025
16 Juni 2025
16 Juni 2025
16 Juni 2025
16 Juni 2025
16 Juni 2025
16 Juni 2025
15 Juni 2025