Lies die bedienungsanleitung für American Audio DJ Scan 250 EX (10 Seiten) kostenlos online; sie gehört zur Kategorie Nicht kategorisiert. Dieses Handbuch wurde von 2 Personen als hilfreich bewertet und erhielt im Schnitt 5.0 Sterne aus 1.5 Bewertungen. Hast du eine Frage zu American Audio DJ Scan 250 EX oder möchtest du andere Nutzer dieses Produkts befragen? Stelle eine Frage

Seite 1/10
User Instructions
American DJ - www.americandj.com - DJ Scan 250 EX Instruction Manual Page 2®
Unpacking: Thank you for purchasing the DJ Scan 250 EX by
American DJ . Every DJ Scan 250 EX has been thoroughly tested ®
and has been shipped in perfect operating condition. Carefully check
the shipping carton for damage that may have occurred during ship-
ping. If the carton appears to be damaged, carefully inspect your x-
ture for any damage and be sure all equipment necessary to operate
the unit has arrived intact. In the event damage has been found or parts
are missing, please contact our toll free customer support number for
further instructions. Please do not return this unit to your dealer with-
out contacting customer support rst.
Introduction: The DJ Scan 250 EX is a five channel, DMX intelligent
fixture. The fixture can used in three different operating modes; stand
alone, Master/Slave configuration, or DMX controlled. The DJ Scan
250 EX can be used as a stand alone or used sound active fixture
in multiples linked in a master/slave configuration. For best results use
fog or special effects smoke to enhance the beams projections.
Customer Support: American DJ provides a toll free customer ®
support line, to provide help and to answer any question should you
encounter problems during your set up or initial operation. You may
also visit us on the web at www.americandj.com for any comments or
5:00 p.m. Pacic Standard Time.
Voice: (800) 322-6337
Fax: (323) 582-2941
E-mail: support@americandj.com
To purchase parts online visit http://parts.americandj.com
not expose this unit to rain or moisture.
into the light source at all times!
DJ Scan 250 EX General Information
American DJ ®
6122 S. Eastern Ave.
Los Angeles Ca. 90040
www.americandj.com
Rev. 4/09
For Your Own Personal Safety, Please Read and Understand This
Manual Completely Before You Attempt To Install Or Operate
This Unit!
To reduce the risk of electrical shock or re, do not expose this unit
rain or moisture
Do not spill water or other liquids into or on to your unit.
Be sure that the local power outlet match that of the required volt-
age for your unit.
Do not attempt to operate this unit if the power cord has been
frayed or broken.
Do not attempt to remove or break off the ground prong from
the electrical cord. This prong is used to reduce the risk of electrical
shock and re in case of an internal short.
Disconnect from main power before making any type of connection.
Do not remove the cover under any conditions. There are no user
serviceable parts inside.
Never operate this unit when its cover is removed.
Always be sure to mount this unit in an area that will allow proper
ventilation. Allow about 6” (15cm) between this device and a wall.
Do not attempt to operate this unit, if it becomes damaged.
This unit is intended for indoor use only, use of this product out-
doors voids all warranties.
Always mount this unit in safe and stable matter.
Power-supply cords should be routed so that they are not likely to
be walked on or pinched by items placed upon or against them,
paying particular attention to cords at plugs, convenience recep-
tacles, and the point where they exit from the appliance.
• Cleaning -The fixture should be cleaned only as recommended by
the manufacturer. See page 15 for cleaning details.
Heat -This fixture should be situated away from heat sources such
as radiators, heat registers, stoves, or other appliances (including
amplifiers) that produce heat.
The fixture should be serviced by qualified service personnel when:
A. Objects have fallen, or liquid has been spilled into the appliance.
B. The appliance has been exposed to rain or water.
C. The appliance does not appear to operate normally or exhibits a
marked change in performance.
DJ Scan 250 EX Safety Precautions
American DJ® - www.americandj.com - DJ Scan 250 EX™ Instruction Manual Page 4American DJ - www.americandj.com - DJ Scan 250 EX Instruction Manual Page 3®
DMX-512 Protocol Compatible (Five DMX Channels)
3 Operating Modes - Master/Slave; Stand Alone; DMX Control
Internal Microphone
Digital Display for Address and Function Setting
UC3 Controller (Not Included)
DJ Scan 250 EX Features
Caution! There are no user serviceable parts inside this unit. Do not
attempt any repairs yourself, doing so will void your manufactures war-
ranty. In the unlikely event your unit may require service please contact
American DJ .®
During operation the housing may become extremely hot. Avoid touch-
ing the unit with bare hands while in use.
American DJ will not accept any liability for any resulting damages ®
caused by the non-observance of this manual or any unauthorized
modication to this unit.
DJ Scan 250 EX Handling Precautions
DJ Scan 250 EX Warranty Registration
The DJ Scan 250 EX carries a limited warranty. 1 year (365 days)
Please fill out the enclosed warranty card to validate your purchase
and warranty. You may also register your product online at www.
americandj.com. All returned service items whether under warranty or
not, must be freight pre-paid and accompany a return authorization
(R.A.) number. If the unit is under warranty you must provide a copy
of your proof of purchase invoice. Please contact American DJ® cus-
tomer support for a R.A. number.
To optimize the performance of this product, please read these
information regarding the use and maintenance of this unit. Please
keep this manual with the unit, for future reference.
DJ Scan 250 EX General Instructions
American DJ - www.americandj.com - DJ Scan 250 EX Instruction Manual Page 6American DJ - www.americandj.com - DJ Scan 250 EX Instruction Manual Page 5 ®®
Power Supply: Before plugging your unit in, be sure the source volt-
age in your area matches the required voltage for your American DJ ®
DJ Scan 250 EX. The American DJ DJ Scan 250 EX®
is available
in a 120v and 220v version. Because line voltage may vary from venue
to venue, you should be sure your unit voltage matches the wall outlet
voltage before attempting to operate you xture. Also be sure to only
use the included I.E.C. power cable supplied with the unit, this cable
matches the voltage and current requirements of the unit.
DMX-512: DMX is short for Digital Multiplex. This is a universal pro-
tocol used by most lighting and controller manufactures as a form of
communication between intelligent fixtures and controllers. A DMX
controller sends DMX data instructions from the controller to the fix-
ture. DMX data is sent as serial data that travels from fixture to fixture
via the DATA IN and DATA OUT XLR terminals located on all DMX
fixtures (most controllers only have a DATA “OUT” terminal).
DMX Linking: DMX is a language allowing all makes and models
compliant. To ensure proper DMX data transmission, when using
several DMX fixtures try to use the shortest cable path possible. The
order in which fixtures are connected in a DMX line does not influence
the DMX addressing. For example; a fixture assigned a DMX address
of 1 may be placed anywhere in a DMX line, at the beginning, at the
end, or anywhere in the middle. Therefore, the first fixture controlled
by the controller could be the last fixture in the chain. When a fixture
is assigned a DMX address of 1, the DMX controller knows to send
DATA assigned to address 1 to that unit, no matter where it is located
in the DMX chain.
Data Cable (DMX Cable) Requirements (For DMX
and Master/Slave Operation): The DJ Scan 250
EX™ can be controlled via DMX-512 protocol. The
DJ Scan 250 EX™ a ve channel DMX unit. The
DMX address is set electronically using the con-
trols on the side panel of the unit. Your unit and
your DMX controller require a standard 3-pin XLR
connector for data input and data output (Figure
1). If you are making your own cables, be sure to use standard two
DJ Scan 250 EX Set Up
Figure 1
conductor shielded cable (This cable may be purchased at almost all
professional sound and lighting stores). Your cables should be made
with a male and female XLR connector on either end of the cable. Also
remember that DMX cable must be daisy chained and cannot be split.
DJ Scan 250 EX Set Up
Notice: Be sure to follow gures two and three when making your own
cables. Do not use the ground lug on the XLR connector. Do not con-
conductor to come in contact with the XLRs outer casing. Grounding
the shield could cause a short circuit and erratic behavior.
DMX512 IN
3-PIN XLR
1
2
3
1
2
3
DMX +
DMX -
COMMON
DMX512 OUT
3-PIN XLR
Figure 2
Figure 3
1 Ground
1 Ground
XLR Male Socket
XLR Pin Conguration
3 Hot
2 Cold
2 Cold
3 Hot
XLR Female Socket
Pin 3 = Data True (positive)
Pin 2 = Data Compliment (negative)
Pin 1 = Ground
Special Note: Line Termination.
When longer runs of cable are
used, you may need to use a terminator on the last unit to avoid erratic
behavior. A terminator is a 90-120 ohm 1/4 watt resistor which is con-
nected between pins 2 and 3 of a male XLR connector (DATA + and
unit in your daisy chain to terminate the line. Using a cable terminator
behavior.
1
2
3
Termination reduces signal errors and
avoids signal transmission problems
and interference. It is always advisable
to connect a DMX terminal, (Resistance
120 Ohm 1/4 W) between PIN 2 (DMX-)
and PIN 3 (DMX +) of the last fixture.