Lies die bedienungsanleitung für American Audio X-Scan LED Plus (10 Seiten) kostenlos online; sie gehört zur Kategorie Nicht kategorisiert. Dieses Handbuch wurde von 2 Personen als hilfreich bewertet und erhielt im Schnitt 4.7 Sterne aus 1.5 Bewertungen. Hast du eine Frage zu American Audio X-Scan LED Plus oder möchtest du andere Nutzer dieses Produkts befragen? Stelle eine Frage

Seite 1/10
American DJ ®
6122 S. Eastern Ave.
Los Angeles CA. 90040
www.americandj.com
8/09
User Instructions
American DJ - www.americandj.com - X-Scan LED Plus Instruction Manual Page 2®
X-Scan LED Plus General Information
Unpacking: Thank you for purchasing the X-Scan LED Plus by Amer-
been shipped in perfect operating condition. Carefully check the ship-
ping carton for damage that may have occurred during shipping. If the
carton appears to be damaged, carefully inspect your xture for any
arrived intact. In the event damage has been found or parts are miss-
ing, please contact our toll free customer support number for further
instructions. Please do not return this unit to your dealer without con-
tacting customer support rst.
Introduction: The X-Scan LED Plus is a eight channel DMX intel-
alone Master/Slave configuration. The X-Scan LED Plus fixture or in a
has two operating modes; sound active mode and DMX control. For
best results use fog or special effects smoke to enhance the beams
projections.
support line, to provide help and to answer any question should you
also visit us on the web at www.americandj.com for any comments or
suggestions. Service Hours are Monday through Friday 9:00 a.m. to
5:00 p.m. Pacic Standard Time.
Voice: (800) 322-6337
Fax: (323) 582-2941
E-mail: support@americandj.com
To purchase parts online visit http://parts.americandj.com
Warning! To prevent or reduce the risk of electrical shock or re, do
not expose this unit to rain or moisture.
Warning! This may cause severe eye damage. Avoid looking directly
into the light source at all times!
For Your Own Personal Safety, Please Read and Understand This
Manual Completely Before You Attempt To Install Or Operate
This Unit!
rain or moisture
Do not spill water or other liquids into or on to your unit.
Be sure that the local power outlet match that of the required volt-
age for your unit.
Do not attempt to operate this unit if the power cord has been
frayed or broken.
Do not attempt to remove or break off the ground prong from
the electrical cord. This prong is used to reduce the risk of electrical
shock and re in case of an internal short.
Disconnect from main power before making any type of connection.
Do not remove the cover under any conditions. There are no user
serviceable parts inside.
Never operate this unit when its cover is removed.
Always be sure to mount this unit in an area that will allow proper
ventilation. Allow about 6 (15cm) between this device and a wall.
Do not attempt to operate this unit, if it becomes damaged.
This unit is intended for indoor use only, use of this product out-
doors voids all warranties.
Always mount this unit in safe and stable matter.
Power-supply cords should be routed so that they are not likely to
be walked on or pinched by items placed upon or against them,
paying particular attention to cords at plugs, convenience recep-
tacles, and the point where they exit from the appliance.
• Cleaning -The fixture should be cleaned only as recommended by
the manufacturer. See page 16 for cleaning details.
Heat -This fixture should be situated away from heat sources such
as radiators, heat registers, stoves, or other appliances (including
amplifiers) that produce heat.
The fixture should be serviced by qualified service personnel when:
A. Objects have fallen, or liquid has been spilled into the appliance.
B. The appliance has been exposed to rain or water.
C. The appliance does not appear to operate normally or exhibits a
marked change in performance.
X-Scan LED Plus Safety Precautions
American DJ - www.americandj.com - X-Scan LED Plus Instruction Manual Page 4American DJ - www.americandj.com - X-Scan LED Plus Instruction Manual Page 3 ®®
DMX-512 Protocol Compatible (Eight DMX Channels)
X/Y Mirror Control
2 Operating Modes - Sound Active and DMX Control
Internal Microphone
Digital Display for Address and Function Setting
UC3 Controller (Not Included)
X-Scan LED Plus Features
attempt any repairs yourself, doing so will void your manufactures war-
ranty. In the unlikely event your unit may require service please contact
American DJ .®
During operation the housing may become extremely hot. Avoid
touching the unit with bare hands while in use.
American DJ will not accept any liability for any resulting damages ®
modication to this unit.
X-Scan LED Plus Handling Precautions
X-Scan LED Plus Warranty Registration
The X-Scan LED Plus carries a 3 year (1095 days) limited warranty.
Please fill out the enclosed warranty card to validate your purchase
and warranty. You may also register your product online at www.
of your proof of purchase invoice. Please contact American DJ® cus-
tomer support for a R.A. number.
To optimize the performance of this product, please read these
information regarding the use and maintenance of this unit. Please
keep this manual with the unit, for future reference.
X-Scan LED Plus General Instructions
American DJ - www.americandj.com - X-Scan LED Plus Instruction Manual Page 6American DJ - www.americandj.com - X-Scan LED Plus Instruction Manual Page 5 ®®
Power Supply: The American DJ X-Scan LED®
Plus contains an elec-
tronic ballast, which will auto sense the voltage when it is plugged into
the power source. With the electronic ballast you do not need to worry
to only use the included I.E.C. power cable supplied with the unit.
DMX-512: DMX is short for Digital Multiplex. This is a universal pro-
controller sends DMX data instructions from the controller to the fix-
ture. DMX data is sent as serial data that travels from fixture to fixture
via the DATA IN and DATA OUT XLR terminals located on all DMX
fixtures (most controllers only have a DATA “OUT” terminal).
DMX Linking: DMX is a language allowing all makes and models
of different manufactures to be linked together and operate from a
compliant. To ensure proper DMX data transmission, when using
several DMX fixtures try to use the shortest cable path possible. The
order in which fixtures are connected in a DMX line does not influence
the DMX addressing. For example; a fixture assigned a DMX address
of 1 may be placed anywhere in a DMX line, at the beginning, at the
end, or anywhere in the middle. Therefore, the first fixture controlled
by the controller could be the last fixture in the chain. When a fixture
is assigned a DMX address of 1, the DMX controller knows to send
DATA assigned to address 1 to that unit, no matter where it is located
in the DMX chain.
Operation): The X-Scan LED Plus can be controlled via DMX-512 pro-
tocol. The X-Scan LED Plus is be a eight channel
DMX unit. The DMX address is set electronically
using the controls on the rear panel of the unit. Your
unit and your DMX controller require a approved
DMX-512 110 Ohm Data cable for data input and
data output (Figure 1). We recommend Accu-Cable
DMX cables. If you are making your own cables, be
sure to use standard 110-120 Ohm shielded cable
(This cable may be purchased at almost all profes-
sional sound and lighting stores). Your cables should be made with
X-Scan LED Plus Set Up
Figure 1
a male and female XLR connector on either end of the cable. Also
remember that DMX cable must be daisy chained and cannot be split.
X-Scan LED Plus Set Up
Notice: Be sure to follow gures two and three when making your own
cables. Do not use the ground lug on the XLR connector. Do not con-
conductor to come in contact with the XLRs outer casing. Grounding
the shield could cause a short circuit and erratic behavior.
DMX512 IN
3-PIN XLR
1
2
3
1
2
3
DMX +
DMX -
COMMON
DMX512 OUT
3-PIN XLR
Figure 2
Figure 3
1 Ground
1 Ground
XLR Male Socket
XLR Pin Conguration
3 Hot
2 Cold
2 Cold
3 Hot
XLR Female Socket
Pin 3 = Data True (positive)
Pin 2 = Data Compliment (negative)
Pin 1 = Ground
Special Note: Line Termination.
When longer runs of cable are
behavior. A terminator is a 110-120 ohm 1/4 watt resistor which is con-
nected between pins 2 and 3 of a male XLR connector (DATA + and
behavior.
1
2
3
Termination reduces signal errors and
avoids signal transmission problems
and interference. It is always advisable
to connect a DMX terminal, (Resistance
120 Ohm 1/4 W) between PIN 2 (DMX-)
and PIN 3 (DMX +) of the last fixture.