Lies die bedienungsanleitung für APC ACCS1009 (8 Seiten) kostenlos online; sie gehört zur Kategorie Nicht kategorisiert. Dieses Handbuch wurde von 32 Personen als hilfreich bewertet und erhielt im Schnitt 4.9 Sterne aus 2 Bewertungen. Hast du eine Frage zu APC ACCS1009 oder möchtest du andere Nutzer dieses Produkts befragen? Stelle eine Frage
Seite 1/8

Rack Air Containment System (ACCS1000–
ACCS1007)—Overview
Introduction
The Rack Air Containment System (RACS) is a mechanical ducting system that attaches to the front
or rear of an enclosure to provide increased cooling capacity. The RACS is a modular system that
works with APC® NetShelter® SX enclosures and InRow®cooling units to provide maximum
cooling predictability, capacity, and efficiency. By attaching the RACS to the rear of the NetShelter
SX, air expelled from IT equipment is forced to pass through the cooling unit, where it is
conditioned. This ensures that warm exhaust air does not enter the air inlets of installed servers.
Redundant configurations allow maximum availability. Optional front containment configurations
reduce noise and provide additional control of air flow. The RACS components can be attached to a
single enclosure or a group of enclosures. The RACS consists of eight components that can be
installed separately or together, depending on your configuration.
• ACCS1000—Rear containment for InRow RC or SC cooling units
• ACCS1001—Rear containment for NetShelter SX and InRow RP cooling units
• ACCS1002—End caps for any rear- or front-containment configuration
• ACCS1003—Front containment for InRow RC or SC cooling units
• ACCS1004—Front containment for InRow RP cooling units
• ACCS1005—Front containment for NetShelter SX enclosures
• ACCS1006—Rear containment for NetShelter SX 750-mm enclosures
• ACCS1007—Front containment for NetShelter SX 750-mm enclosures
Features of the RACS
• Rear containment—Ensures server exhaust air is returned to the InRow cooling unit for
maximum cooling predictability. Prevents recirculation of hot exhaust air.
• Front containment—Ensures cold supply air is not captured by neighboring equipment.
• Modular design—Compatible with standard NetShelter SX enclosures, providing maximum
system flexibility and scalability.
• Redundant configurations—Provide N + 1 or uding additional InRow 2N redundancy by incl
cooling units.
• Clear polycarbonate door inserts—Provide required air containment while allowing visibility
to installed IT equipment and a consistent appearance across enclosures.
• Lockable doors—Provide enclosure security.
• Noise reduction—Containment of both the front and rear of the enclosure reduces the level of
noise generated by the installed equipment.
• ACCS1000—Rear containment for InRow 300mm cooling units
• ACCS1001—Rear containment for NetShelter SX and InRow RP cooling units
• ACCS1002—End caps for any rear- or front-containment configuration
• ACCS1003—Front containment for InRow 300mm (100 series) cooling units
• ACCS1004—Front containment for InRow 600mm cooling units
• ACCS1005—Front containment for NetShelter SX enclosures
• ACCS1006—Rear containment for NetShelter SX 750-mm enclosures
• ACCS1007—Front containment for NetShelter SX 750-mm enclosures
• ACCS1009—Front containment for InRow 300mm (300 series) ACRC301S/H
Rack Air Containment System (ACCS1000–
ACCS1009)—Overview
Produktspezifikationen
| Marke: | APC |
| Kategorie: | Nicht kategorisiert |
| Modell: | ACCS1009 |
| Breite: | 300 mm |
| Tiefe: | 196 mm |
| Gewicht: | 13640 g |
| Produktfarbe: | Schwarz, Silber |
| Höhe: | 1911 mm |
| Sperren: | Ja |
| Verpackungsbreite: | 508 mm |
| Verpackungstiefe: | 2032 mm |
| Verpackungshöhe: | 152 mm |
| Paketgewicht: | 22550 g |
| Zertifizierung: | REACH |
| Warentarifnummer (HS): | 85389099 |
| Typ: | Frontabdeckung |
| Nachhaltigkeitszertifikate: | RoHS |
Brauchst du Hilfe?
Wenn Sie Hilfe mit APC ACCS1009 benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten
Bedienungsanleitung Nicht kategorisiert APC
31 Oktober 2025
10 September 2025
3 September 2025
3 September 2025
3 September 2025
11 August 2025
11 August 2025
25 Juli 2025
15 Juli 2025
11 Juli 2025
Bedienungsanleitung Nicht kategorisiert
Neueste Bedienungsanleitung für -Kategorien-
3 April 2026
3 April 2026
3 April 2026
3 April 2026
3 April 2026
3 April 2026
3 April 2026
3 April 2026
3 April 2026
3 April 2026