APC SMX040 Bedienungsanleitung
Lies die bedienungsanleitung für APC SMX040 (8 Seiten) kostenlos online; sie gehört zur Kategorie Kabel für PCs und Peripheriegeräte. Dieses Handbuch wurde von 27 Personen als hilfreich bewertet und erhielt im Schnitt 5.0 Sterne aus 14 Bewertungen. Hast du eine Frage zu APC SMX040 oder möchtest du andere Nutzer dieses Produkts befragen? Stelle eine Frage
Seite 1/8

Smart-UPS
®
X-Series 120 VDC
External Battery Pack Installation
Inventory
Safety and General Information
Read the Safety Guide included in the package before installation.
This unit is intended for indoor use only.
Do not operate this unit in direct sunlight, in contact with fluids, or where there is excessive dust or humidity.
Be sure the air vents on the external battery packs (XLBPs) are not blocked. Allow adequate space for proper
ventilation.
The battery typically lasts for two to five years. Environmental factors impact battery life. Elevated ambient
temperatures, poor quality utility power, and frequent short duration discharges will shorten battery life.
Always install the XLBPs at the bottom of the rack. The UPS must be installed above the XLBPs.
Specifications
For additional specifications, refer to the APC web site at www.apc.com.
Environmental
(1) (1) (6) (4) (1)
(1) (2) (2) (2)
Temperature
Operating 0° to 40° C (32° to 104° F)
Storage -15° to 45° C (5° to 113° F)
charge UPS battery every six months
Maximum
Elevation
Operating 3,000 m (10,000 ft)
Storage 15,000 m (50,000 ft)
Humidity
0% to 95% relative humidity, non-condensing
su0577b
s
u
0
4
3
4
a

Smart-UPS X-Series XLBP2
Installation
Electrical Hazard:
Before installing or replacing the batteries, remove jewelry such as
wristwatches and rings. High short-circuit current through conductive materials could cause
severe burns.
• The Smart-UPS unit will recognize up to ten XLBPs using the display interface, however there is
no limit to the number of XLBPs that can be used with the UPS.
• Always install the XLBPs below the UPS in a rack configuration.
• Connect all battery strings. Failure to do so may cause equipment damage.
Remove the Shipping Brackets
Remove the battery
Each battery weighs 23 kg (51 lbs). Remove the batteries before installation in a
rack.
1 2
1 2
3 4
su0
7
3
8
c
s
u
0
7
3
8
d
s
u
0
5
7
4
a
s
u
0
5
7
4
b
s
u
0
5
8
4
a
s
u
0
5
7
3
a

Smart-UPS X-Series XLBP 3
Four-post rack installation
Rack-mount brackets may differ by model.
Two-post rack
1 2
Use the APC Four-Post Rail Kit.
3 4
5 6
1 2
s
u
0
4
4
0
a
s
u
0
5
7
0
a
s
u
0
5
7
1
a
s
u
0
5
7
8
a
s
u
0
5
7
2
a
s
u
0
5
7
5
a
su0576a
Produktspezifikationen
Marke: | APC |
Kategorie: | Kabel für PCs und Peripheriegeräte |
Modell: | SMX040 |
Brauchst du Hilfe?
Wenn Sie Hilfe mit APC SMX040 benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten
Bedienungsanleitung Kabel für PCs und Peripheriegeräte APC
8 Oktober 2024
8 August 2024
31 Juli 2024
29 Juli 2024
19 Juli 2024
Bedienungsanleitung Kabel für PCs und Peripheriegeräte
- Honeywell
- Speed-Link
- HQ
- Approx
- Gembird
- Cisco
- J5 Create
- Comprehensive
- Pyle
- McIntosh
- Targus
- Platinum
- Sanus
- Chief
- IPort
Neueste Bedienungsanleitung für -Kategorien-
1 Oktober 2024
1 Oktober 2024
1 Oktober 2024
30 September 2024
29 September 2024
24 September 2024
23 September 2024
21 September 2024
21 September 2024
21 September 2024