Lies die bedienungsanleitung für Berner High Performance 7 (12 Seiten) kostenlos online; sie gehört zur Kategorie Nicht kategorisiert. Dieses Handbuch wurde von 4 Personen als hilfreich bewertet und erhielt im Schnitt 4.8 Sterne aus 2.5 Bewertungen. Hast du eine Frage zu Berner High Performance 7 oder möchtest du andere Nutzer dieses Produkts befragen? Stelle eine Frage

Seite 1/12
1
Thank you for choosing Berner.
Berner International has been saving energy and creating healthy, comfortable environments for our customers for over 60 years.
Berner oers unmatched quality, performance, and dependability—not to mention our service. At Berner, we stand behind our products.
TABLE OF CONTENTS
I. UNCRATING............................................................................................................................................................ ........................................................ 2
II. GENERAL MOUNTING INSTRUCTIONS ................................................................................................................................. ................................... 4
III. WALL MOUNTING ...................................................................................................................................................................................................... 5
IV. SUSPENDED MOUNTING ....................................................................................................................................... ................................................... 6
V. ELECTRICAL CONNECTIONS ..................................................................................................................................................................................... 7
VI. FIELD CONNECTIONS ................................................................................................................................................................................................ 7
VII. OPERATING INSTRUCTIONS .................................................................................................................................................................................... 8
VIII. MAINTENANCE AND CLEANING ............................................................................................................................................................................ 9
IX. SERVICE ............................................................................................................................................................... ........................................................ 9
X. TROUBLESHOOTING ................................................................................................................................................................................................. 10
XI. APPENDIX
PUREAIR PACKAGE™ ................................................................................................................................................................................................ 11
XII.WARRANTY ................................................................................................................................................ ............................................................... 12
Installation & Maintenance Instructions
Commercial High Performance 10
Air Curtain Series #CHD10
Sanitation Certied High Performance 7
Air Curtain Series #SHD07
www.Berner.com
II-123D
July, 2024
©Copyright, 2024 Berner International
READ ALL INSTRUCTIONS BEFORE INSTALLING OR USING AIR CURTAIN
USDA
COMPLIANCE
for outdoor use
SHD07
SHD07
®
When the door is open
, BERNER AIR CURTAINS
FDA
RECOMMENDED
ANSI/NSF 37
Air Curtain Fans
for Customer Entry
max.mounting
height is 7’
SHD07
2
Carefully examine the carton(s) for damage. If the carton is
damaged, immediately notify the shipping company. Do not
delay in ling claim. If the air curtain(s) were shipped on
wooden skids, remove protective wood and banding straps
securing the carton(s) to the skid. Open the carton(s) and
remove all protective packaging.
Immediately verify that the electrical rating nameplate located
on the cover matches electrical power supply available. Retain
the shipping carton(s) until the air curtain(s) are installed and
properly operating.
ACCESSORIES:
If the air curtain was ordered with a wall mounting plate,
remove and save the two (2) locking screws from the back
corners and detach the wall mounting plate. See Figure 1.
If the air curtain(s) were ordered with optional electrical accessories, the
accessories will be found in the carton containing the air curtain packed
in a red bag (marked additional parts inside”) or in a separate carton(s)
accompanying the air curtain(s).
Check all of the cartons/skids for accessories before discarding.
A. Read all instructions before installing or using this air curtain.
B. Use this unit only in the manner intended by the manufacturer and described in this manual. Any other use not recommended by the
manufacturer may cause re, electric shock, or injury to persons. If you have any questions, contact the manufacturer.
C. Before servicing or cleaning unit, switch power o at service panel and lock the service disconnecting means to prevent power from
being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device,
such as a tag, to the service panel.
D. Installation work and electrical wiring must be done by qualied person(s) in accordance with all applicable national and local codes
having jurisdiction, including re-rated construction. See page 7, ELECTRICAL CONNECTIONS (NEC Code ANSI/NFPA No. 70).
E. When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities.
F. To reduce the risk of re, do not store or use gasoline or other ammable vapors and liquids in the vicinity of the air curtain.
G. This air curtain is hot when in use. To avoid burns, do not let bare skin touch hot surfaces. Keep combustible materials, such as furniture,
pillows, bedding, papers, clothes, etc. and curtains at least 1 inch from the top, back, front, sides and at least 6 feet from the discharge
of the air curtain.
H. Extreme caution is necessary when any air curtain is used by or near children or invalids, and whenever the heater is left operating
unattended.
I. Do not operate any air curtain after it malfunctions. Disconnect power at the service panel and have the air curtain inspected by a
reputable electrician before reusing.
J. To disconnect the air curtain, turn controls to "o", and turn o power to the air curtain circuit at main disconnect panel.
K. Do not insert or allow foreign objects to enter any ventilation or discharge opening as this may cause an electric shock or re, or
damage the air curtain.
L. To prevent a possible re, do not block the air intake or discharge of the air curtain in any manner.
M. The air curtain has hot and arcing or sparking parts inside. Do not use it in areas where gasoline, paint, or ammable vapors or liquids
are used or stored.
N. This heater may include an audible or visual alarm to warn that parts of the heater are getting excessively hot. If the alarm sounds
(or illuminates), immediately turn the heater o and inspect for any objects on or adjacent to the heater that may have blocked the airow
or otherwise caused high temperatures to have occurred. DO NOT OPERATE THE HEATER WITH THE ALARM SOUNDING (OR ILLUMINATING).
WARNING: TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:
I. UNCRATING
Commercial High
Performance 10
Air Curtain
(Air Door)
Sanitation Certied
High Performance 7
Air Curtain
(Air Door)
Figure 1