AIM 1,6/0,8
Lies die bedienungsanleitung für Block AIM 1,6/0,8 (2 Seiten) kostenlos online; sie gehört zur Kategorie Nicht kategorisiert. Dieses Handbuch wurde von 46 Personen als hilfreich bewertet und erhielt im Schnitt 4.5 Sterne aus 23.5 Bewertungen. Hast du eine Frage zu Block AIM 1,6/0,8 oder möchtest du andere Nutzer dieses Produkts befragen? Stelle eine Frage
Seite 1/2

Data SheetDisposal
Please observe the current regulations and dispose according to type of material
i. e. as electronic scrap (printed circuit boards), plastics (housing), steel, copper etc.
Amendments
We have produced this documentation with the utmost care, however no guarantee
for completeness or correctness can be given. The adoption of this information in
an application must be individually checked. The technical details describe the
product features without guaranteeing these. This product is subject to changes
that serve the technical advancement.
Operation Information
The natural cooling of this equipment must not be impaired. An unobstructed air
circulation and a distance of at least 30 mm to neighbouring components should
be observed.
The transformer must be disconnected from the mains supply before replacing
blown fuses, or wiring of the terminals.
Due to the protection index (IP 20), the use of this equipment is only permitted in
dry areas.
This transformer does not provide isolation from mains voltage.
Connection plan
The input, output connection terminals and output fuse link are in the same com-
partment at one end of the housing. In the compartment at the other end are the
terminals and jumpers which enable the required (input and output voltages to be
chosen).
(AIM 10/5; AIM 16/8 on one terminal block).
Required Jumper Required Jumper
input voltage between output voltage between
240 V B - 1 240 V A - 1
230 V B - 2 230 V A - 2
220 V B - 3 220 V A - 3
115 V B - 4 115 V A - 4
Example for application:
Input voltage 220 V, output voltage 240 V
jumper between B - 3 and A - 1
Dependant on the input voltage setting, the max. current that can be drawn from
the output is limited to the values that can be taken from the data sheet.
The standard voltage settings on delivery are 240 V input and 115 V output.
A secundary fuse link for the smaller current rating at 115 V input voltage, is
secured in the cover of the terminal compartment.
To secure the voltage isolation values of the load, the common auto - transformer
point ”N and N’” should be connected to the mains neutral lead.
V
!
Safety and user Information
Congratulations to the ownership of this high quality product. A long life expectancy
is assured if used in the described manner and correct application. As with all
technical products, a hazard to health or equipment can exist if improperly used,
the unauthorized removal of necessary covers, incorrect installation or incorrect
operation is present. Follow these instructions and adhere to the generally accepted
rules of technology. Installation and setting-up should only be carried out by qualified
personnel (IEC 60364 / VDE 0105).
Packaging
Carefully check the equipment immediately after receipt, for transport damage,
deformation, and loose parts. Any damage should be reported without delay to the
transport carrier, even then when no apparent damage to external packaging is
visible.
Storage
Permitted storage temperature : -25°C...+85°C
Permitted humidity : 30...80 % relative humidity
No condensation during operation.
Extended storage : Equipment containing capacitors
should be connected to the mains
supply for at least 5 min. every
two years.
Installation and Operation
This equipment is to be protected against improper use. Components are not to be
bent or isolation spacings to be changed, when transported or handled. The contact
with electrical components and terminals is to be avoided.
Always disconnected the equipment from the mains supply before installation or
wiring is started!
During operation this equipment can have (depending on the protection index)
hazardous live parts or hot surfaces. The product desciption, technical information
in our main catalogue and the marking on the equipment and ratings plate are to
be observed. The installation must be carried out according to the prevailing local
conditions, prevailing safety standards (e. g. VDE 0100), national accident preven-
tion regulations (e. g. UVV - VBG 4; BGV A 2 respectively) and the generally
accepted rules of technology.
This equipment can be used independantly or as a component for electrical
installation or machines, and fulfils the requirements of the low voltage guidelines
(73/23/EWG). When installed into machinery, the normal operation is forbidden
until it is determined that the machine fulfils the requirements of the machinery
guidelines (89/392/EWG), attention must be paid to EN 60 204. Normal operation
in the intended use can only begin when the EMC guidelines (89/336/EWG) are
fulfilled. The observance of the required limitations for the EMC legislation, is the
responsibility of the manufacturer of the installation or machinery.
Maintenance and Servicing
Electrical equipment generally requires no special maintenance, are however
(depending on the protection index) to be protected against dust build-up, moisture,
radiation and aggressive chemicals. Servicing is only permitted under the terms
and conditions of these operating instructions. Nevertheless should a failure occur,
please return the equipment to us for repair giving the following information: Type
of fault, accompanying symptoms (operation conditions), your own speculation as
to the cause of the failure, previous unusual conditions etc..
Type Input Output Output no load Specified fuse Weight
voltage voltage current losses value
V V A typ. W AT kg
AIM 1,6/0,8 220 / 230 / 240 115 / 220 / 230 / 240 1,6 4,7 1,6 2,10
115 220 / 230 / 240 0,8 4,7 0,8 2,10
AIM 3,2/1,6 220 / 230 / 240 115 / 220 / 230 / 240 3,2 6,7 3,2 3,60
115 220 / 230 / 240 1,6 6,7 1,6 3,60
AIM 5,0/2,5 220 / 230 / 240 115 / 220 / 230 / 240 5,0 11,8 5,0 5,00
115 220 / 230 / 240 2,5 11,8 2,5 5,00
AIM 10/5 220 / 230 / 240 115 / 220 / 230 / 240 10,0 18,0 10 AgG 12,10
115 220 / 230 / 240 5,0 18,0 5,0 AT0
AIM 16/8 220 / 230 / 240 115 / 220 / 230 / 240 16,0 21,0 16 AgG 16,50
115 220 / 230 / 240 8,0 21,0 8,0 AgG0
Diagramm
(factory setting)
AIM 1,6/0,8; AIM 3,2/1,6; AIM 5,0/2,5
AIM 10/5; AIM 16/8
BLOCK Transformatoren-Elektronik
Gebrauchsanleitung
Spartransformator Typ AIM
Instruction leaflet
Auto transformer Type AIM
BLOCK Transformatoren-Elektronik GmbH
Max-Planck-Straße 36-46 • 27283 Verden • Germany
Phone: +49 4231 678-0 • Fax: +49 4231 678-177
[email protected] • www.block-trafo.de
BLOCK Belgium BVBA
Nieuwstraat 2 • 3200 Aarschot • Belgium
Phone: +32 16 69 45 • Fax: +32 16 69 79 72
[email protected] • www.block-trafo.com
BLOCK UK LTD.
24 Bentalls Centre, Colchester Road
Heybridge • Maldon, Essex CM9 4GD • United Kingdom
Phone: +44 1621 85-06 66 • Fax: +44 1621 85-07 11
[email protected] • www.block-trafo.com
BLOCK USA Inc.
1370 Bowes Road, Suite 110
Elgin • Illinois 60123
Phone: +1 847 214 8900 • Fax: +1 224 569 4312
www.blockusa.com • [email protected]
Stand: 04/2011
Unbenannt-2.indd 1 05.04.11 11:41
Produktspezifikationen
| Marke: | Block |
| Kategorie: | Nicht kategorisiert |
| Modell: | AIM 1,6/0,8 |
Brauchst du Hilfe?
Wenn Sie Hilfe mit Block AIM 1,6/0,8 benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten
Bedienungsanleitung Nicht kategorisiert Block
20 Juli 2025
20 Juli 2025
20 Juli 2025
20 Juli 2025
20 Juli 2025
20 Juli 2025
20 Juli 2025
20 Juli 2025
20 Juli 2025
19 Juli 2025
Bedienungsanleitung Nicht kategorisiert
- Richgro
- Inverx
- Ovente
- Storex
- Valcom
- Bintec-elmeg
- Esperanza
- MQ
- Kaiser Fototechnik
- GoPro
- Kelty
- Black Diamond
- Appsys ProAudio
- Duro Pro
- Klavis
Neueste Bedienungsanleitung für -Kategorien-
21 Januar 2026
21 Januar 2026
21 Januar 2026
21 Januar 2026
21 Januar 2026
21 Januar 2026
21 Januar 2026
21 Januar 2026
21 Januar 2026
21 Januar 2026