Brocade Mobility 5181 Bedienungsanleitung
Brocade
Zugangspunkt
Mobility 5181
Lies die bedienungsanleitung für Brocade Mobility 5181 (2 Seiten) kostenlos online; sie gehört zur Kategorie Zugangspunkt. Dieses Handbuch wurde von 15 Personen als hilfreich bewertet und erhielt im Schnitt 4.3 Sterne aus 8 Bewertungen. Hast du eine Frage zu Brocade Mobility 5181 oder möchtest du andere Nutzer dieses Produkts befragen? Stelle eine Frage
Seite 1/2

To the installer
This guide is intended for the technician responsible for installing the Brocade
Mobility 5181 model access point. It assumes the technician is familiar with
basic Ethernet LAN-based networking and device installation concepts. This
guide provides specifications, procedures and guidelines to use during the
installation process. This guide does not provide site-specific installation
procedures. For detailed site-specific installation procedures, refer to the site-
specific documentation derived from site survey and site network analysis.
Note - This Mobility 5181 Installation Guide is intended to assist installers with
the installation of the Mobility 5181. Once secured in its intended operational
position, refer to the Mobility 5181 Product Reference Guide for detailed
instructions on configuring the access point’s feature set. For more information,
go to http://www.brocade.com/support
.
Verifying package contents
Inspect the contents and report any missing or damaged items to your sales
representative.
The Mobility 5181 access point ships with the following components:
• 1 Mobility 5181 802.11 a+bg dual-radio access point
• 1 Mobility 5181 Installation Guide (this document)
• 1 set of cable connectors
• 3 antenna connector dust covers
• 2 connector cover AP67 jacks, plus chain_LTW-M9/14-SB
• 1 Waste Electrical and Equipment (WEEE) addendum
Note: A RJ-45 to Serial (9-pin D) cable is required to make a connection to the
Mobility 5181’s Console port. This cable is not supplied and must be provided by
the customer.
To mount the Mobility 5181 access point to a pole (1.5 - 18 inches in diameter)
or wall, a Mobility 5181 Mounting Kit (Part No. BR-KT-5181-WP-01R) can be
separately ordered. This kit contains the brackets and accessories required to
mount the access point.
If installing the Mobility 5181 in an outdoor area prone to high winds and rain,
Brocade recommends using the Mobility 5181 Heavy Weather Kit
(Part No. BR-KT-5181-HW-01R). This kit affords additional protection to shield a
Mobility 5181 from high wind and water damage as a result of driving rain.
If using a single port Power-Over Ethernet solution to supply power to the Mobility
5181, Brocade recommends using the Mobility 5181 Power Tap (Part No. BR-
APPSBIAS518101R). This single port POE solution is designed specifically for
outdoor use with the Mobility 5181.
Safety information
Before operating any equipment, review this document for any hazards
associated with installation and use of the device. Also, review standard
practices for preventing accidents.
• Only trained and qualified personnel should install and remove the Power
Tap.
• The power cord must be a three-conductor type (two current carrying
conductors and one ground conductor terminated on one end by an IEC
60320 appliance coupler (for Power Tap connection) and on the other end
by a plug containing a ground (earth) contact.
• The power cord must be rated for a minimum of 250VAC RMS operation,
with a minimum rated current capacity of 5A [or a minimum wire gauge of
18AWG (0.75mm²)].
•The Power Tap Data and Data & Power interfaces are qualified as SELV
(Safety Extra-Low Voltage) circuits according to IEC 60950. These
interfaces can only be connected to SELV interfaces on other equipment.
Warnings
• Read the installation instructions before connecting the Power Tap to a
power source.
• Follow basic electricity safety measures whenever connecting the Power
Tap to its power source.
• This product relies on the building installation for short-circuit (over current)
protection. Ensure a fuse or circuit breaker no larger than 120 VAC, 3A U.S.
(240VAC, 1.5A international) is used on the phase conductor.
• A voltage mismatch can cause equipment damage and could pose a fire
hazard. If the voltage indicated on the label is different from the power
outlet voltage, do not connect the Power Tap to that particular outlet.
• The Power Tap Data In and Data & Power Out ports are shielded RJ-45
sockets. Only RF-45 data connectors should be connected to these
sockets.
Service information
Before using the unit, it must be configured to operate in the facility’s network
and run your applications. If you have a problem running your unit or using your
equipment, contact your facility’s Technical or Systems Support. If there is a
problem with the equipment, they will contact the Brocade Support Center.
Brocade Communications Systems, Incorporated
Corporate and Latin American Headquarters
Brocade Communications Systems, Inc.
130 Holger Way
San Jose, CA 95134
Tel: 1-408-333-8000 Fax: 1-408-333-8101
E-mail: inf[email protected]
European Headquarters
Brocade Communications Switzerland Sàrl
Centre Swissair
Tour B - 4ème étage
29, Route de l'Aéroport
Case Postale 105
CH-1215 Genève 15
Switzerland
Tel: +41 22 799 5640 Fax: +41 22 799 5641
E-mail: emea-info@brocade.com
Asia-Pacific Headquarters
Brocade Communications Systems China HK, Ltd.
No. 1 Guanghua Road
Chao Yang District
Units 2718 and 2818
Beijing 100020, China
Tel: +8610 6588 8888 Fax: +8610 6588 9999
E-mail: china-info@brocade.com
53-1001562-02
Brocade Mobility 5181
Installation Guide
(2)
(1)
(3) (4) (5) (6)
Introduction
The Mobility 5181 is a ruggedized access point designed for outdoor
deployments. The Mobility 5181 employs a dual-mode simultaneous 802.11a
and 802.11b/g radio solution.
Product description
The Mobility 5181 has a separate LAN and WAN port for connecting to the
network and receiving power (over the Mobility 5181’s LAN port only). The
Mobility 5181 has four antenna connectors (on top) supporting 802.11a and
802.11b/g antenna options..
Mounting the Mobility 5181
The Mobility 5181 can be mounted to a pole (1.5 - 18 inches in diameter) or to a
wall. The Mobility 5181 Wall Mounting Kit (Part No. BR-KT-5181-WP-01R) is not
included with Mobility 5181 and must be ordered separately.
The mounting bracket has four parts. One rectangular plate used for pole and
wall mounting, one square plate that attaches directly to the Mobility 5181 and
two plates forming an adjustable V-shaped clamp for pole mounting.
Mounting the Mobility 5181 on a pole
1. Ensure the Mobility 5181 is oriented properly, and fit the edges of the V-
shaped clamp parts into the slots on the flat side of the rectangular plate.
2. Place the V-shaped bracket clamp parts around the pole and tighten the
nuts just enough to hold the bracket to the pole. (The bracket may need to
be rotated around the pole during the antenna alignment process).
3. Attach the square mounting plate to the access point with the supplied
screws.
4. Attach the Mobility 5181 and mounting plate to the bracket already fixed to
the pole. If necessary, use the “U-bracket” (included in the mounting kit), in
conjunction with the band clamp, to expand the diameter of the bracket to
a maximum if 18 inches.
5. Secure the Mobility 5181 to the pole.
Note: The Mobility 5181 tilt angle may need to be adjusted during the antenna
alignment process. Verify the antenna polarization angle when installing, and
ensure the antennas are oriented correctly in respect to the Mobility 5181's
coverage area.
Mounting the Mobility 5181 on a wall
1. Ensure the Mobility 5181 is oriented properly, and attach the bracket to a
wall with flat side flush against the wall. Position the bracket in the
intended location and mark the positions of the four mounting screw holes.
2. Drill four holes in the wall that match the screws and wall plugs.
3. Secure the bracket to the wall.
4. Attach the square mounting plate to the Mobility 5181 with the supplied
screws. Attach the Mobility 5181 to the plate on the wall.
5. Secure the Mobility 5181 to the bracket. Fit the edges of the V-shaped
clamp parts into the slots on the flat side of the rectangular plate.
Technical specifications
Physical specifications
Dimensions 12 inches (30.48 cm) long x 8.25 (20.96 cm) inches
wide x 3.5 inches (8.89 cm) thick
Housing Aluminum
Weight 4 lbs.
Environmental specifications
Temperature -30°C to 55°C (Operating), -40°C to 85°C (Storage)
Humidity 5% to 95% Non-condensing (both Operating and Storage)
Altitude 8,000 feet/2438 m @28°C (Operating)
15,000 feet/4572 m @12°C (Storage)
Electrostatic Discharge15kV (air) @ 50% rh, 8kV (contact) @ 50% r
Drop Bench drop 36 inches (9.14 cm) to concrete
Wind Blown Rain 40 MPH @ 0.1inch/minute, 15 minutes
Rain/Drip/Spill IPX6 Spray @ 4L/minute, 10 minutes
Dust IP5X 20mb vacuum max, 2 hours, stirred dust, .88g/m^3
Electrical specifications
Operating Voltage 48Vdc (Nom)
Operating Current 250mA (Peak) @ 48Vdc/170mA (Nom) @ 48Vdc
Antenna specifications
The Mobility 5181 2.4 GHz antenna suite includes the following models:
Caution: The 2.4 and 5.5 GHz antenna models listed are rated for the Mobility
5181 model access point and its intended outdoor deployment.
Fit the edges of the
V-shaped part into the slots
Tighten the
securing bolts
Attach the square
plate to the bridge
sym 029
Part number Antenna type Gain (dBi)
ML-2499-FHPA5-01R Omni-Directional 8.0
ML-2499-FHPA9-01R Omni-Directional 9.0
ML-2452-PNA7-01R Panel (Dual-Band) 8.0
ML-2452-PNA5-01R Sector (Dual-Band) 5.0
®
Produktspezifikationen
| Marke: | Brocade |
| Kategorie: | Zugangspunkt |
| Modell: | Mobility 5181 |
Brauchst du Hilfe?
Wenn Sie Hilfe mit Brocade Mobility 5181 benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten
Bedienungsanleitung Zugangspunkt Brocade
3 September 2025
3 September 2025
30 August 2024
16 April 2024
Bedienungsanleitung Zugangspunkt
- EQ-3
- AirLive
- EnGenius
- Intellinet
- Cudy
- Homematic IP
- SilverNet
- Aruba
- FlyingVoice
- IP-COM
- Fortinet
- Mikrotik
- Meraki
- Vimar
- Macally
Neueste Bedienungsanleitung für -Kategorien-
11 Januar 2026
11 Januar 2026
11 Dezember 2025
11 Dezember 2025
8 Dezember 2025
4 November 2025
1 November 2025
17 Oktober 2025
17 Oktober 2025
12 Oktober 2025