Lies die bedienungsanleitung für Canon CanoScan LIDE 70 (2 Seiten) kostenlos online; sie gehört zur Kategorie Scanner. Dieses Handbuch wurde von 133 Personen als hilfreich bewertet und erhielt im Schnitt 4.8 Sterne aus 9 Bewertungen. Hast du eine Frage zu Canon CanoScan LIDE 70 oder möchtest du andere Nutzer dieses Produkts befragen? Stelle eine Frage

Seite 1/2
Checking the Package Contents
1
1
1
11 Scanner
2
2
2
22 USB Interface Cable
3
3
3
33 Stand
4
4
4
44 CanoScan Setup Utility CD-ROM
5
5
5
55 Quick Start Guide
Installing the Software
Do NOT connect the scanner to a computer before installing the software.
Quit all running applications before installation, including anti-virus software.
For Windows 2000/XP, log in as an administrator to install the software.
1
1
1
11 Place the CanoScan Setup Utility CD-ROM in the drive.
CanoScan Setup Utility program starts.
For Macintosh: Double-click the [Setup] icon. Enter the administrator ID and password on the authentication
dialog box.
2
2
2
22 Click [Easy Install] on the main menu.
3
3
3
33 Click [Install] to start installation.
Carefully read the License Agreement, and then click [Yes] to proceed.
Follow the on-screen instructions to perform the installation.
All the software programs and on-screen manuals will be installed on your computer.
4
4
4
44 When the Information dialog is displayed, click [ok] to restart your computer.
For Macintosh: Skip this step and go to the step 5.
5
5
5
55 Follow the on-screen instructions to register your product.
6
6
6
66 When the installation is complete, click [Exit].
For Macintosh: Click [Restart] to restart your computer.
Preparing the Scanner
1
1
1
11 Slide the lock switch on the bottom of the scanner toward the unlock mark ().
Always lock the scanner when carrying or transporting it.
2
2
2
22 Connect the scanner to the computer with the supplied USB cable.
Only use the USB cable provided with the scanner. Use of other cables may lead to a malfunction.
The scanner does not have a power switch. The power is activated as soon as the computer is turned on.
When the scanner is connected to the USB 1.1 port on Windows XP and HI-SPEED USB Device Plugged into
non-HI-SPEED USB Hub message appears, ignore the message. The scanner operates in this condition
without problems.
Try Scanning
1
1
1
11 Place a document on the document glass and close the document cover.
2
2
2
22 Start ArcSoft PhotoStudio.
For Windows: Select [start]-[(All) Programs]-[ArcSoft PhotoStudio 5.5], then click [PhotoStudio 5.5].
For Macintosh: Open [Applications]-[PhotoStudio] folders, then double-click the [PhotoStudio] icon.
3
3
3
33 Click [File] menu, [Select Source] and select the scanner model.
For Windows: Do not select the one that includes [WIA] in the model name.
4
4
4
44 Click the acquire icon to start ScanGear.
5
5
5
55 Select the type of document you are scanning in [Select Source] and click [Preview].
6
6
6
66 Click [Scan] to start scanning.
Do not move the scanner while it is operating.
7
7
7
77 When prompted to close ScanGear, click [OK].
8
8
8
88 Save the scanned image in ArcSoft PhotoStudio and close the window.
Using the Scanner Buttons
Refer to the Scanning Guide (on-screen manual) for further information about ScanGear, CanoScan Toolbox,
Scanner Buttons, Troubleshooting and Setting the Stand. To start the Scanning Guide, double-click the on-screen
manual icon on the desktop.
In this guide, Windows XP screen shots are used to illustrate explanations common to all operating systems.
Quick Start Guide
1
4
5
23
Bottom
Top
COPY Button
Prints (copies) the scanned image with a printer.
PDF Button
Saves the scanned image as a PDF file.
PHOTO Button
Opens the scanned image in the bundled application
program, ArcSoft PhotoStudio.
E-MAIL Button
Attaches the scanned image to a new e-mail
message.
QT5-0800-V02 ©CANON INC. 2006 PRINTED IN VIETNAM
• For Mac OS X 10.3/10.2.8: Refer to Troubleshooting in the Scanning Guide (on-screen manual) before using.

Bewerten Sie dieses Handbuch

4.8/5 (9 Bewertungen)

Produktspezifikationen

Marke: Canon
Kategorie: Scanner
Modell: CanoScan LIDE 70
USB Anschluss: Ja
Gewicht: 1700 g
Betriebstemperatur: 5 - 35 °C
Stromverbrauch (Standardbetrieb): 3 W
Stromverbrauch (Standby): 2 W
USB-Version: 2.0
Min. benötigter RAM: 128 MB
Kompatible Betriebssysteme: -Windows 98, 98SE, 2000 Pro, ME, XP;\n-Mac OS X v10.2.8;
Abmessungen (BxTxH): 258 x 374 x 40 mm
Mitgelieferte Software: ArcSoft PhotoStudio, ScanSoft OmniPage SE & Presto!PageManager
Standard-Schnittstellen: USB 2.0
Sensor-Typ: CIS
Optische Scan-Auflösung: 2400 x 4800 DPI
Scanner-Typ: Flachbettscanner
Mindestsystemvoraussetzungen: -CD ROM drive;\n-High colour (16bit);\n-1024 x 768 display;
Maximale Scan-Abmessung: 216 x 297 mm
Farbscannen: Ja
Filmabtastung: Nein
Minimum Prozessor: Pentium II 300Mhz
Min. benötigter Speicherplattenplatz: 450 MB
Eingabe Farbtiefe: 48 Bit

Brauchst du Hilfe?

Wenn Sie Hilfe mit Canon CanoScan LIDE 70 benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten