Canon CanoScan LIDE 70 Bedienungsanleitung

Canon Scanner CanoScan LIDE 70

Lies die bedienungsanleitung für Canon CanoScan LIDE 70 (4 Seiten) kostenlos online; sie gehört zur Kategorie Scanner. Dieses Handbuch wurde von 128 Personen als hilfreich bewertet und erhielt im Schnitt 5.0 Sterne aus 64.5 Bewertungen. Hast du eine Frage zu Canon CanoScan LIDE 70 oder möchtest du andere Nutzer dieses Produkts befragen? Stelle eine Frage

Seite 1/4
Checking the Package Contents
1
1
1
11 Scanner
2
2
2
22 USB Interface Cable
3
3
3
33 Stand
4
4
4
44 CanoScan Setup Utility CD-ROM
5
5
5
55 Quick Start Guide
Installing the Software
Do NOT connect the scanner to a computer before installing the software.
Quit all running applications before installation, including anti-virus software.
For Windows 2000/XP, log in as an administrator to install the software.
1
1
1
11 Place the CanoScan Setup Utility CD-ROM in the drive.
CanoScan Setup Utility program starts.
For Macintosh: Double-click the [Setup] icon. Enter the administrator ID and password on the authentication
dialog box.
2
2
2
22 Click [Easy Install] on the main menu.
3
3
3
33 Click [Install] to start installation.
Carefully read the License Agreement, and then click [Yes] to proceed.
Follow the on-screen instructions to perform the installation.
All the software programs and on-screen manuals will be installed on your computer.
4
4
4
44 When the Information dialog is displayed, click [ok] to restart your computer.
For Macintosh: Skip this step and go to the step 5.
5
5
5
55 Follow the on-screen instructions to register your product.
6
6
6
66 When the installation is complete, click [Exit].
For Macintosh: Click [Restart] to restart your computer.
Preparing the Scanner
1
1
1
11 Slide the lock switch on the bottom of the scanner toward the unlock mark ().
Always lock the scanner when carrying or transporting it.
2
2
2
22 Connect the scanner to the computer with the supplied USB cable.
Only use the USB cable provided with the scanner. Use of other cables may lead to a malfunction.
The scanner does not have a power switch. The power is activated as soon as the computer is turned on.
When the scanner is connected to the USB 1.1 port on Windows XP and HI-SPEED USB Device Plugged into
non-HI-SPEED USB Hub message appears, ignore the message. The scanner operates in this condition
without problems.
Try Scanning
1
1
1
11 Place a document on the document glass and close the document cover.
2
2
2
22 Start ArcSoft PhotoStudio.
For Windows: Select [start]-[(All) Programs]-[ArcSoft PhotoStudio 5.5], then click [PhotoStudio 5.5].
For Macintosh: Open [Applications]-[PhotoStudio] folders, then double-click the [PhotoStudio] icon.
3
3
3
33 Click [File] menu, [Select Source] and select the scanner model.
For Windows: Do not select the one that includes [WIA] in the model name.
4
4
4
44 Click the acquire icon to start ScanGear.
5
5
5
55 Select the type of document you are scanning in [Select Source] and click [Preview].
6
6
6
66 Click [Scan] to start scanning.
Do not move the scanner while it is operating.
7
7
7
77 When prompted to close ScanGear, click [OK].
8
8
8
88 Save the scanned image in ArcSoft PhotoStudio and close the window.
Using the Scanner Buttons
Refer to the Scanning Guide (on-screen manual) for further information about ScanGear, CanoScan Toolbox,
Scanner Buttons, Troubleshooting and Setting the Stand. To start the Scanning Guide, double-click the on-screen
manual icon on the desktop.
In this guide, Windows XP screen shots are used to illustrate explanations common to all operating systems.
Quick Start Guide
1
4
5
23
Bottom
Top
COPY Button
Prints (copies) the scanned image with a printer.
PDF Button
Saves the scanned image as a PDF file.
PHOTO Button
Opens the scanned image in the bundled application
program, ArcSoft PhotoStudio.
E-MAIL Button
Attaches the scanned image to a new e-mail
message.
QT5-0800-V02 ©CANON INC. 2006 PRINTED IN VIETNAM
• For Mac OS X 10.3/10.2.8: Refer to Troubleshooting in the Scanning Guide (on-screen manual) before using.


Produktspezifikationen

Marke: Canon
Kategorie: Scanner
Modell: CanoScan LIDE 70
USB Anschluss: Ja
Gewicht: 1700 g
Betriebstemperatur: 5 - 35 °C
Stromverbrauch (Standardbetrieb): 3 W
Stromverbrauch (Standby): 2 W
USB-Version: 2.0
Min. benötigter RAM: 128 MB
Kompatible Betriebssysteme: -Windows 98, 98SE, 2000 Pro, ME, XP;\n-Mac OS X v10.2.8;
Abmessungen (BxTxH): 258 x 374 x 40 mm
Mitgelieferte Software: ArcSoft PhotoStudio, ScanSoft OmniPage SE & Presto!PageManager
Standard-Schnittstellen: USB 2.0
Sensor-Typ: CIS
Optische Scan-Auflösung: 2400 x 4800 DPI
Scanner-Typ: Flachbettscanner
Mindestsystemvoraussetzungen: -CD ROM drive;\n-High colour (16bit);\n-1024 x 768 display;
Maximale Scan-Abmessung: 216 x 297 mm
Farbscannen: Ja
Filmabtastung: Nein
Minimum Prozessor: Pentium II 300Mhz
Min. benötigter Speicherplattenplatz: 450 MB
Eingabe Farbtiefe: 48 Bit

Brauchst du Hilfe?

Wenn Sie Hilfe mit Canon CanoScan LIDE 70 benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten