Chauvet Maverick Force 2 BeamWash Bedienungsanleitung

Chauvet Beleuchtung Maverick Force 2 BeamWash

Lies die bedienungsanleitung für Chauvet Maverick Force 2 BeamWash (16 Seiten) kostenlos online; sie gehört zur Kategorie Beleuchtung. Dieses Handbuch wurde von 2 Personen als hilfreich bewertet und erhielt im Schnitt 4.6 Sterne aus 1.5 Bewertungen. Hast du eine Frage zu Chauvet Maverick Force 2 BeamWash oder möchtest du andere Nutzer dieses Produkts befragen? Stelle eine Frage

Seite 1/16
English EN
Español ES
Français FR
Deutsch DE
Nederlands NL
Quick Reference Guide
Model ID: MAVERICKFORCE2BEAMWASH
Scan the QR code to
access the product page,
warranty terms, and the
complete User Manual
1
QUICK REFERENCE GUIDE
Maverick Force 2 BeamWash QRG Rev. 1
Safety Notes
These Safety Notes include important information about installation, use, and maintenance of the
Maverick Force 2 BeamWash.
FCC Compliance
This device complies with Part 15 Part B of the FCC rules. Operation is subject to the following two conditions:
1. This device may not cause harmful interference, and
2. This device must accept any interference received, including interference that may cause undesired operation.
Any changes or modifications not expressly approved by the party responsible for compliance could void the user’s
authority to operate the equipment.
RF Exposure Warning for North America and Australia
Warning! This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This
equipment should be installed and operated with a minimum distance of 20 cm between the radiator and the user. This
transmitter must not be co-located or operating in conjunction with any other antenna or transmitter.
The luminaire is intended for professional use only.
The luminaire should be positioned so that prolonged staring into the luminaire at a distance closer than 16.4
ft (5 m) is not expected.
If the external flexible cable or cord of this luminaire is damaged, it shall be replaced by a special cord or cord
exclusively available from the manufacturer or its service agent.
The light source contained in this luminaire shall only be replaced by the manufacturer or its service agent or
a similar qualified person.
CAUTION:
This product’s housing may be hot when operating. Mount this product in a location with adequate
ventilation, at least 20 in (50 cm) from adjacent surfaces.
When transferring the product from extreme temperature environments, (e.g., cold truck to warm humid
ballroom) condensation may form on the internal electronics of the product. To avoid causing a failure,
allow the product to fully acclimate to the surrounding environment before connecting it to power.
Flashing light is known to trigger epileptic seizures. User must comply with local laws regarding notification
of strobe use.
ALWAYS:
Disconnect from power before cleaning the product or replacing the fuse.
When using an IP65-rated product in an outdoor environment, use IP65- (or higher) rated power and data
cable.
Replace and secure IP-rated protective covers to all power, data, USB, or other ports when not in use.
Replace the fuse with the same type and rating.
Use a safety cable when mounting this product overhead.
Connect this product to a grounded and protected circuit.
DO NOT:
Open this product. It contains no user-serviceable parts.
Look at the light source when the product is on.
Leave any flammable material within 100 cm of this product while operating or connected to power.
Connect this product to a dimmer or rheostat.
Operate this product if the housing, lenses, or cables appear damaged.
Operate this product outdoors or in any location where dust, excessive heat, water, or humidity may affect
it (adhere to standards for the published IP rating).
Submerge this product (adhere to standards for the published IP rating). Regular outdoor operation is fine.
Permanently install outdoors in locations with extreme environmental conditions. This includes, but is not
limited to:
Exposure to a marine/saline environment (within 3 miles of a saltwater body of water).
Locations where normal temperatures exceed the temperature ranges in this manual.
Locations that are prone to flooding or being buried in snow.
Other areas where the product will be subject to extreme radiation or caustic substances.
ONLY use the hanging/mounting bracket to carry this product.
The maximum ambient temperature is 113 °F (45 °C). Do not operate this product at higher temperatures.
The minimum startup temperature is -4°F (-20°C). Do not start the product at lower temperatures.
To eliminate unnecessary wear and improve its lifespan, during periods of non-use completely disconnect the
product from power via breaker or by unplugging it.
In the event of a serious operating problem, stop using immediately.
EN
2
Maverick Force 2 BeamWash QRG Rev. 1
QUICK REFERENCE GUIDE
What is Included
AC Power
This product has an auto-ranging power supply that can work with an input voltage range of 100–240 VAC, 50/60 Hz.
AC Plug
Power Linking
It is possible to power link up to 1 Maverick Force 2 BeamWash products at 100 V, 2 products at 120 V, 4 products at 208
V, 4 products at 230 V, or up to 4 products at 240 V. Never exceed this number. Power-linking cables can be purchased
separately.
Mounting
Before mounting this product, read the Safety Notes. Use at least 2 mounting points per product. Make sure the mounting
clamps are capable of supporting the weight of the product. For our Chauvet line of mounting clamps, go to http://
trusst.com/productcategory/truss-clamps.
Mounting Diagram
Control Panel Description
Maverick Force 2 BeamWash
Seetronic Powerk
on ower IP65 p cable
2 omega brackets with mounting hardware
Quick Reference Guide
Connection Wire (U.S.) Wire (Europe) Screw Color
AC Live Black Brown Yellow/Brass
AC Neutral White Blue Silver
AC Ground Green/Yellow Green/Yellow Green
To eliminate unnecessary wear and improve its lifespan, during periods of non-use completely
disconnect the product from power via breaker or by unplugging it.
Button Name Function
<UP> Navigates upwards through the menu list or increases the numeric value when in a function
<MENU> Exits from the current menu or function
<DOWN> Navigates downwards through the menu list or decreases the numeric value when in a function
<LEFT> Navigates leftwards through the menu list
<ENTER> Enables the currently displayed menu or sets the currently selected value into the selected function
<RIGHT> Navigates rightwards through the menu list
Safety cable
Mounting clamp
Overhead mounting
Surface mounting
Omega
bracket (2x)


Produktspezifikationen

Marke: Chauvet
Kategorie: Beleuchtung
Modell: Maverick Force 2 BeamWash

Brauchst du Hilfe?

Wenn Sie Hilfe mit Chauvet Maverick Force 2 BeamWash benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten