ClimeMET CM3505 Bedienungsanleitung


Lies die bedienungsanleitung für ClimeMET CM3505 (2 Seiten) kostenlos online; sie gehört zur Kategorie Messgeräte. Dieses Handbuch wurde von 46 Personen als hilfreich bewertet und erhielt im Schnitt 4.4 Sterne aus 9 Bewertungen. Hast du eine Frage zu ClimeMET CM3505 oder möchtest du andere Nutzer dieses Produkts befragen? Stelle eine Frage

Seite 1/2
Wet & Dry Bulb Hygrometer
CM3505 User Guide
The ClimeMET Wet & Dry Bulb Hygrometer measures relative humidity.
Getting Started
There are two mounng hooks at the top and boom of the Hygrometer.
These can be used to hook your Hygrometer onto axing, or to screw your Hygrometer
to a wall or fence post. Place the Hygrometer at least 1.5 metres above the ground.
Avoid any areas that may be subjected to extreme heat or cold.
the water tank. Fill the water tank withltered water or clean rain water and place back
into the Hygrometer. Aach the wick to the base of the wet thermometer (like a sock),
and then gently feed the other end of the wick through the hole into the water tank.
Once this is done, place the Hygrometer in your desired locaon and wait at least 1
hour to take a reading.
Taking a Reading
To take a reading, youll need the Hygrometric Conversion Table that came with your
Hygrometer to determine the % relave humidity. This is calculated from the dry bulb
temperature and the wet bulb depression.
Record the temperature of the wet bulb and then the dry bulb. Subtract the wet
temperature from the dry temperature. This will give you the depression of the wet
bulb. Using the dry temperature and the wet bulb depression,nd your relave
humidity reading at the point where these two values meet on the conversion table.
An example is shown below.
© 2021 ClimeMET. All Rights Reserved.
0.51.01.52.02.53.03.54.04.55.05.56.06.57.07.58.0
-11019079695949393020
09052443425781716116
1811390736455473829204
28273645749332499141171
383746557494336287912114
49283756759433532254511811
592847668534638248261312115
6928577706255483427206411412
7938578645750443730245711711
89386797265595246393327932115
Depression of Wet Bulb °C (Dry Bulb Temperature minus Wet Bulb Temperature)
Dry Bulb Temperature (°C)

Bewerten Sie dieses Handbuch

4.4/5 (9 Bewertungen)

Produktspezifikationen

Marke: ClimeMET
Kategorie: Messgeräte
Modell: CM3505

Brauchst du Hilfe?

Wenn Sie Hilfe mit ClimeMET CM3505 benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten