Lies die bedienungsanleitung für Conceptronic ZEUS52ES1K (7 Seiten) kostenlos online; sie gehört zur Kategorie Unterbrechungsfreies Stromversorgungssystem. Dieses Handbuch wurde von 3 Personen als hilfreich bewertet und erhielt im Schnitt 4.3 Sterne aus 2 Bewertungen. Hast du eine Frage zu Conceptronic ZEUS52ES1K oder möchtest du andere Nutzer dieses Produkts befragen? Stelle eine Frage
Seite 1/7

User’s Manual
ZEUS52E1K / ZEUS52ES1K
ZEUS52E2K / ZEUS52ES2K
ZEUS52E3K / ZEUS52ES3K

2
IMPORTANT SAFETY INSTRUCTIONS
This manual contains important instructions. Please read and follow all instructions carefully during installation and operation of the unit. Read this
manual thoroughly before attempting to unpack, install, or operate the UPS.
CAUTION! The UPS must be connected to a grounded AC power outlet with fuse or circuit breaker protection. DO NOT plug the UPS into an outlet
that is not grounded. If you need to power-drain this equipment, turn o and unplug the unit.
CAUTION! The battery can power hazardous components inside the unit, even when the AC input power is disconnected.
CAUTION! The UPS should be placed near the connected equipment and easily accessible.
CAUTION! To prevent the risk of re or electric shock, install in a temperature and humidity controlled indoor area, free of conductive contaminants.
(Please see specications for acceptable temperature and humidity range).
CAUTION! (No User Serviceable Parts): Risk of electric shock, do not remove cover. No user serviceable parts inside. Refer servicing to qualied
service personnel.
CAUTION! (Non-Isolated Battery Supply): Risk of electric shock, battery circuit is not isolated from AC power source; hazardous voltage may
exist between battery terminals and ground. Test before touching.
CAUTION! To reduce the risk of re, connect the UPS to a branch circuit with 10 amperes (1000 / 1500 / 00) / 16 amperes (3000) maximum 20
over-current protection in accordance to CE requirement.
CAUTION! The AC outlet where the UPS is connected should be close to the unit and easily accessible.
CAUTION! Please use only VDE-tested, CE-marked mains cable, (e.g. the mains cable of your equipment), to connect the UPS to the AC outlet.
CAUTION! Please use only VDE-tested, CE-marked power cables to connect any equipment to the UPS.
CAUTION! When installing the equipment, ensure that the sum of the leakage current of the UPS and the connected equipment does not exceed
3.5mA.
CAUTION! The 1000 / 1500 / 2000 / 3000 / Battery module models are only qualied maintenance personnel may carry out installations.
CAUTION! Do not unplug the unit from AC Power during operation, as this will invalidate the protective ground insulation.
CAUTION! To avoid electric shock, turn o and unplug the unit before installing the input/output power cord with a ground wire. Connect the ground
wire prior to connecting the line wires!
CAUTION! Do not use an improper size power cord as it may cause damage to your equipment and cause re hazards.
CAUTION! Wiring must be done by qualied personnel.
CAUTION! DO NOT USE FOR MEDICAL OR LIFE SUPPORT EQUIPMENT! Under no circumstances this unit should be used for medical
applications involving life support equipment and/or patient care.
CAUTION! DO NOT USE WITH OR NEAR AQUARIUMS! To reduce the risk of re, do not use with or near aquariums. Condensation from the
aquarium can come in contact with metal electrical contacts and cause the machine to short out.
CAUTION! Do not dispose of batteries in re as the battery may explode.
CAUTION! Do not open or mutilate the battery, released electrolyte is harmful to the skin and eyes.
CAUTION! A battery can present a risk of electric shock and high short circuit current. The following precaution should be observed when working
on batteries
1. Remove watches, rings or other metal objects.
2. Use tools with insulated handles.
CAUTION! The unit has a dangerous amount of voltage. When the UPS indicators is on, the units may continue to supply power thus the unit’s
outlets may have a dangerous amount of voltage even when it’s not plugged in to the wall outlet.
CAUTION! Make sure everything is turned o and disconnected completely before conducting any maintenance, repairs or shipment.
CAUTION! Connect the Protection Earth (PE) safety conductor before any other cables are connected.
WARNING! (Fuses): To reduce the risk of re, replace only with the same type and rating of fuse.
DO NOT INSTALL THE UPS WHERE IT WOULD BE EXPOSED TO DIRECT SUNLIGHT OR NEAR A STRONG HEAT SOURCE!
DO NOT BLOCK OFF VENTILATION OPENINGS AROUND THE HOUSING!
DO NOT CONNECT DOMESTIC APPLIANCES SUCH AS HAIR DRYERS TO UPS OUTPUT SOCKETS!
SERVICING OF BATTERIES SHOULD BE PERFORMED OR SUPERVISED BY PERSONNEL KNOWLEDGE OF BATTERIES A AD THE
REQUIRED PRECAUTIONS. KEEP UNAUTHORIZED PERSONNEL AWAY FROM BATTERIES!
INSTALLING YOUR UPS SYSTEM
UNPACKING
(1) UPSx1; (2) User s manual x1; (3) Input power cord (EU/UK) x2; (4) USB cable x1; (5) RS232 cable x1’
INSTALLING YOUR UPS SYSTEM
HARDWARE INSTALLATION GUIDE
1. Battery charge loss may occur during shipping and storage. Before using the UPS, it’s strongly recommended to charge batteries for four hours to
ensure the batteries’ maximum charge capacity. To recharge the batteries, simply plug the UPS into an AC outlet.
2. Connect your computer, monitor, and any externally-powered data storage device (Hard drive, Tape drive, etc.) into the outlets only when the UPS
is o and unplugged. DO NOT plug a laser printer, copier, space heater, vacuum, paper shredder or other large electrical device into the UPS.
The power demands of these devices will overload and possibly damage the unit.
3. To protect a fax machine, telephone, modem line or network cable, connect the telephone or network cable from the wall jack outlet to the jack
marked “IN” on the UPS and connect a telephone cable or network cable from the jack marked “OUT” on the UPS to the modem, computer,
telephone, fax machine, or network device.
4. Press the ON switch to turn the UPS on. If an overload is detected, an audible alarm will sound and the UPS will continuously emit one beep per

3
second. For resetting the unit, unplug some equipment from the outlets. Make sure your equipment carries a load current withi n the unit’s safe
range, (refer to the technical specications).
5. This UPS is equipped with an auto-charge feature. When the UPS is plugged into an AC outlet, the battery will automatically charge, even when
the unit is switched o.
6. To maintain an optimal battery charge, leave the UPS plugged into an AC outlet at all times.
7. Before storing the UPS for an extended period of time, turn the unit OFF. Then cover it and store it with the batteries fully charged. Recharge the
batteries every three months to ensure good battery capacity and long battery life. Ma intaining a good battery charge will help prevent possible
damage to the unit from battery leakage.
8. The UPS has one USB port (default) and one Serial port that allows connection and communication between the UPS and any attac hed computer
running the Power Master software. The UPS can control the computer’s shutdown during a power outage through the connection while the
computer can monitor the UPS and alter various programmable parameters.
Note: Only one communication port can be used at a time. The port not in use will automatically become disabled or the serial port will be disabled
if both ports are attached.
9. To avoid electric shock, turn the unit OFF and disconnect the unit from utility power before hardwiring the UPS (in/out power cord). The in/out
power cord be grounde MUST d.
BASIC OPERATION
POWER MODULE FRONT/REAR PANEL DESCRIPTION
1. Power On/O Button
Master ON/OFF for the UPS.
2. Function Buttons
.,Scroll up, scroll down, select and cancel LCD menu.
3. Multifunction LCD Readout
Indicate status information, settings and events.
4. Battery Backup & Surge Protected Outlets
Provide battery backup and surge protection. They ensure power
is provided to connected equipment over a period of time during a
power failure.
5. Serial Port
Serial port provides communication between the UPS and the
computer. The UPS can control the computer’s shutdown during a
power outage through the connection while the computer can
monitor the UPS and alter its various programmable parameters.
6. EPO (Emergency Power O) Connector
Enable Power-O in emergency from a remote location.
7. USB port
This is a connectivity port which allows communication and
control between the UPS and the connected computer. It is
recommended to install the Power master software on the
PC/Server connected with the USB cord.
8. SNMP/HTTP Network slot
Slot to install the optional SNMP card for remote network control
and monitoring.
9. AC Input Inlet
Connect the AC Power cord to a properly wired and grounded
outlet.
10. Input Circuit Breaker
Provide input overload and fault protection.
11. Extended Runtime Battery Module Connector(only for long
run models)
Connect to additional external battery modules.
12. Output Terminal Block
Connect to your equipment.
Produktspezifikationen
Marke: | Conceptronic |
Kategorie: | Unterbrechungsfreies Stromversorgungssystem |
Modell: | ZEUS52ES1K |
Brauchst du Hilfe?
Wenn Sie Hilfe mit Conceptronic ZEUS52ES1K benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten
Bedienungsanleitung Unterbrechungsfreies Stromversorgungssystem Conceptronic
9 Juni 2025
9 Juni 2025
Bedienungsanleitung Unterbrechungsfreies Stromversorgungssystem
- Middle Atlantic
- Tripp Lite
- Bxterra
- Schneider
- Steren
- Adj
- Qoltec
- JUNG
- Digitus
- HP
- APC
- Voltcraft
- PowerWalker
- FSP/Fortron
- Altronix
Neueste Bedienungsanleitung für -Kategorien-
31 Mai 2025
1 Dezember 2024
22 Juni 2024
22 Juni 2024
20 Juni 2024
20 Juni 2024
20 Juni 2024
20 Juni 2024
20 Juni 2024