Lies die bedienungsanleitung für Crestron CHV-TSTATEX-W-T (2 Seiten) kostenlos online; sie gehört zur Kategorie Thermostat. Dieses Handbuch wurde von 49 Personen als hilfreich bewertet und erhielt im Schnitt 4.3 Sterne aus 25 Bewertungen. Hast du eine Frage zu Crestron CHV-TSTATEX-W-T oder möchtest du andere Nutzer dieses Produkts befragen? Stelle eine Frage
Seite 1/2

1
quickstart guide
CHV-TSTATEX
www.crestron.com
888.273.7876 201.767.3400
Specifications subject to
change without notice.
CHV-TSTATEX
For details, refer to the latest version of the
CHV-TSTATEX Operations & Installation Guide, Doc. 6989.
QUICKSTART DOC. 6990B (2027559) 01.12
infiNET EX® Thermostat
DIP Switch Settings
# DESCRIPTION
4 System Type Heat/Cool Heat Pump
3 Heat Pump Mode Aux Heat Dual Fuel
2 Cool/HP Stages 1 2
1 Heat Stages 1 2
ON OFF
# DESCRIPTION
4 Fan In Heat Disabled Enabled
3 Change Over Outputs Disabled Enabled
2 Cool SP Range Normal Extended
1 N/A N/A N/A
ON OFF
LEFT SWITCH
RIGHT SWITCH
STEAL
(LEFT)
24VAC
(RIGHT)
Power Steal Switch
ON
1 234
1 234
ON
Single Stage Heat-Only ApplicationSingle Stage Cool-Only Application
Mount the thermostat directly to
drywall or to a single-gang box in
accordance with accepted building
codes and practices. If using the
single-gang box, be sure to fill it with
thermal insulation material.
For additional details and installation
options, refer to the latest version of
the CHV-TSTATEX Operations &
Installation Guide (Doc. 6989). It is
available from the Crestron® Web site
(www.crestron.com/manuals).
Mounting
1
2
Connections
Connect the thermostat using the four most typical wiring configurations shown below as a guide. Refer to “DIP Switch Settings” on the left to
configure each application. For more information, refer to the latest version of the CHV-TSTATEX Operations & Installation Guide (Doc. 6989).
Heat Pump Application With
Integrated ControllerHeat - Cool Application With
Integrated Control Unit
Transformer
Heat
Relay
Optional, for power
R
C
System
DIP Switch Settings
ON
1 234
1 234
ON
R
C
C
Y
G
R
Compressor
Relay
Fan
Relay
DIP Switch Settings
ON
1 234
1 234
ON
R
C
C
W
Y
G
R
Optional, for power
RH and RC must be
jumpered together.
Heat
Relay
Fan
Relay
Cool
Relay
DIP Switch Settings
ON
1 234
1 234
ON
R
C
C
Y
G
O
E - U - W
R
Compressor
Relay
Fan
Relay
Changeover
Valve
Aux Heat
Relay
RH and RC must be
jumpered together.
DIP Switch Settings
ON
12 3 4
12 3 4
ON
Optional, for power
Optional,
for power
System
Transformer
System
Transformer
System
Transformer
Produktspezifikationen
| Marke: | Crestron |
| Kategorie: | Thermostat |
| Modell: | CHV-TSTATEX-W-T |
Brauchst du Hilfe?
Wenn Sie Hilfe mit Crestron CHV-TSTATEX-W-T benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten
Bedienungsanleitung Thermostat Crestron
30 August 2025
30 August 2025
21 August 2024
21 August 2024
21 August 2024
20 August 2024
20 August 2024
20 August 2024
20 August 2024
20 August 2024
Bedienungsanleitung Thermostat
Neueste Bedienungsanleitung für -Kategorien-
19 Januar 2026
14 Januar 2026
14 Januar 2026
13 Januar 2026
2 Januar 2026
29 Dezember 2026
27 Dezember 2025
25 Dezember 2025
23 Dezember 2025
23 Dezember 2025