Lies die bedienungsanleitung für Daikin BAF552AA160 (8 Seiten) kostenlos online; sie gehört zur Kategorie Klimaanlage. Dieses Handbuch wurde von 5 Personen als hilfreich bewertet und erhielt im Schnitt 4.7 Sterne aus 3 Bewertungen. Hast du eine Frage zu Daikin BAF552AA160 oder möchtest du andere Nutzer dieses Produkts befragen? Stelle eine Frage
Seite 1/8

Installation manual
High performance pre-filter
English
Installation manual
High performance pre-filter
BAF552AA160

Table of contents
Installation manual
2
BAF552AA160
High performance pre-filter
4P706412-1 – 2022.12
Table of contents
1 About this document 2
2 About the kit 2
2.1 Components .............................................................................. 2
2.2 Compatibility.............................................................................. 2
3 Installation 2
3.1 Before installation...................................................................... 2
3.2 Installation site requirements of the unit.................................... 2
3.3 To install the pre-filter................................................................ 2
4 Configuration 3
4.1 Field setting ............................................................................... 3
5 Disposal 3
1 About this document
Target audience
Authorised installers
Documentation set
This document is part of a documentation set. The complete set
consists of:
▪General safety precautions:
▪ Safety instructions that you must read before installing
▪ Format: paper (in the box of the indoor unit)
▪Installation manual:
▪ Installation instructions
▪ Format: paper (supplied in the kit)
Latest revisions of the supplied documentation may be available on
the regional Daikin website or via your dealer.
Scan the QR code below to find the full documentation set and more
information about your product on Daikin website.
The original documentation is written in English. All other languages
are translations.
2 About the kit
NOTICE
▪ Read this manual carefully before installation together
with all documents from the documentation set, see
"1About this document"[42].
▪ Be sure to use only the specified components delivered
with the option kit when installing.
▪ When the Daikin high performance pre-filter is installed, air
volume, performance and operation sound of the indoor unit may
be altered.
▪ Only the Daikin high performance pre-filter is permitted for
replacement.
▪ Daikin high performance pre-filter CANNOT be used with other
filters, chambers, fresh air intake kits or air discharge outlet
sealing member kit (for selection of 2 or 3 way air blow).
▪ Replace the filter when the filter sign is displayed on the remote
controller.
▪ Contact your dealer for instruction regarding installation or
replacement of the filter.
2.1 Components
Make sure you have all the following part included in your kit:
2× 2× 2×1×
a b c d
aDaikin high performance pre-filter
bScrew
cTie wrap
dClamp
2.2 Compatibility
Combine the Daikin high performance pre-filter with the following
indoor units:
2‒1 Model group
Group A Group B Group C Group D
FCAG35~60
FXFQ20~32
FXFA20~32
FCAG71
FCAHG71~140
FXFQ40~63
FXFA40~63
FCAG100~140
FXFQ80+100
FXFN50+112
FXFA80+100
FXFQ125
FXFA125
FXFN71
Refer to this table when performing ["4.1Field setting" 43].
For a full list of compatible units, refer to the option list.
3 Installation
3.1 Before installation
Check the ["2.2Compatibility" 42] before installation.
Refer to the installation and operation manual of the indoor unit and
the decoration panel.
3.2 Installation site requirements of
the unit
Do NOT install in places:
▪ With mineral oil, or filled with oil vapour or spray, like in
kitchens.
▪ Where corrosive gas like sulphurous gas exists.
▪ Where the humidity is ≥90% and the temperature is
≥65°C.
▪ That require a high ceiling mode setting and 2/3 way
blow mode setting of the indoor unit.
3.3 To install the pre-filter
Open the suction grille.
1Slowly lower the suction grille while pressing down on the two
knobs.

4 Configuration
Installation manual
3
BAF552AA160
High performance pre-filter
4P706412-1 – 2022.12
2Release the strap of the suction grille from the hook (2
locations). Open the suction grille in 45° angle.
45°
1
2
Remove the original air filter from suction grille.
3Pull the end of the original air filter diagonally down to unhook
the air filter from the suction grille.
4Lift up the air filter and remove the original air filter from the
hook on the suction grille.
1
2
3
Attach Daikin high performance pre-filter.
5Attach 2 clamps (delivered with the kit). Do NOT overtight the
screw to avoid damaging the suction grille.
6Position the Daikin high performance pre-filter with airflow
indicator on the high performance pre-filter frame. Point in the
same direction of the airflow.
7Install the Daikin high performance pre-filter securely and fix
with tie wraps. The direction of the clamp should match the
figure.
8Cut of excess tie wraps.
Re-install the suction grille.
9Perform steps 1 and 2 in reverse order to re-install the suction
grille. Refer to the installation manual provided with the indoor
unit and decoration panel.
Finish the installation
10 Perform the field setting, see ["4.1Field setting" 43].
11 Perform the test run, see the installation manual of the indoor
unit.
Replacing the Daikin high performance pre-filter.
12 Cut and remove the tie wraps and remove the Daikin high
performance pre-filter.
13 Follow steps 6~8 to install new filter.
4 Configuration
4.1 Field setting
After installation of the Daikin high performance pre-filter make the
following field settings:
▪ Air volume setting
▪ Filter sign setting
INFORMATION
Following setting are only applicable when using the
BRC1H52* user interface. When using any other user
interface, see the installation manual or service manual of
the user interface.
Setting: Air volume setting
Setting
(1)
For model group (refer to
" 2‒1 Model group"[
4
4
4
44
2])
M SW —
A 13 (23) 0 03
1 02
B 0 02
1 02
C 1 02
D 0 03
Setting: Filter sign setting
Setting
(1)
M SW —
All models 10 (20) 0 01
5 Disposal
Prerequisite: Turn off the indoor unit before removing the pre-filter.
1While wearing protective glasses, mask and gloves open the
suction grille and remove the pre-filter.
2Put the pre-filter in plastic bag and close tightly.
(1)
Field settings are defined as follows:
• : Mode number – : for group of units – : for individual unitM First number Number between brackets
• : Setting numberSW
• —: Value number
Produktspezifikationen
Marke: | Daikin |
Kategorie: | Klimaanlage |
Modell: | BAF552AA160 |
Brauchst du Hilfe?
Wenn Sie Hilfe mit Daikin BAF552AA160 benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten
Bedienungsanleitung Klimaanlage Daikin
13 Juni 2025
13 Juni 2025
13 Juni 2025
13 Juni 2025
13 Juni 2025
13 Juni 2025
13 Juni 2025
13 Juni 2025
13 Juni 2025
13 Juni 2025
Bedienungsanleitung Klimaanlage
- Daitsu
- HTW
- DEXP
- Koenig
- Oregon Scientific
- Dimplex
- Black And Decker
- Saunier Duval
- Emerson
- Evapolar
- Khind
- Prem-i-air
- Vox
- Emerio
- Moa
Neueste Bedienungsanleitung für -Kategorien-
19 Juni 2025
19 Juni 2025
18 Juni 2025
17 Juni 2025
17 Juni 2025
17 Juni 2025
17 Juni 2025
17 Juni 2025
17 Juni 2025
17 Juni 2025