Dormakaba HSB-E11 Bedienungsanleitung


Lies die bedienungsanleitung für Dormakaba HSB-E11 (4 Seiten) kostenlos online; sie gehört zur Kategorie Nicht kategorisiert. Dieses Handbuch wurde von 23 Personen als hilfreich bewertet und erhielt im Schnitt 4.5 Sterne aus 8 Bewertungen. Hast du eine Frage zu Dormakaba HSB-E11 oder möchtest du andere Nutzer dieses Produkts befragen? Stelle eine Frage

Seite 1/4
Subject to change without notice
50 -3/16"
(1290)
35-7/16"
(900)
37-3/16"
(945)
HSB-E11
31-7/8"
(810)
5-1/8"
(130)
5-1/8"
(130)
42-1/18"
(1070)
25-9/16"
(650)
HSB-E11 sensor barriers
Economical
Economical units offer a minimal
installation length and a simple
sensor system monitors the
passage area by offering single
passage in both directions.
Standard unitsHSB-E11
Note: Description of single unit
Interlock height
37-3/16" (945)
Interlock length
50-13/16" (1290)
Passage width
25-9/16" (650)
Total width 42-1/8" (1070)
Housing, base columns,
guiding elements
AISI 304 Ø2-3/8" (Ø60) stainless steel tube with 3/8" (10)
toughened safety glass panel and AISI 304 stainless steel
handrail with integrated sensor system.
ADA compliance36" (915) width available.
Barrier elements
Two door leaves made of transparent polycarbonate, upper edge
3-7/16" (900).
Swinging area monitored by separation sensors.
SecurityPassage area monitored by simple sensor system with our
shortest installation length (simple level of single passage
monitoring in both directions).
FinishStainless steel semi-gloss smooth finish.
SafetyLow energy drive with energy content less than 1.18 lb/ft.
FunctionType 2–power assisted motion; two servo-positioning drives/
electrically controlled in both directions.
DrivesIntegrated in the swing tube.
Operating modesOptical.
Normally closed.
Normally opened. (Barriers close on tailgate event.)
Electrical equipmentControl system and power supply integrated in the unit.
Power supply110 – 230 VAC, 50/60 Hz. 368 VA
Standby power consumption17 VA
Standard adjustment in case
of power failure
Door leaves move freely.
InstallationDowelled on finished floor level, FFL.
Not suitable for outdoor installation.
Protection classesHousing IP32, components conducting supply voltage IP42. Entrance systems

Bewerten Sie dieses Handbuch

4.5/5 (8 Bewertungen)

Produktspezifikationen

Marke: Dormakaba
Kategorie: Nicht kategorisiert
Modell: HSB-E11

Brauchst du Hilfe?

Wenn Sie Hilfe mit Dormakaba HSB-E11 benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten