Dormakaba RCI 3510LM Bedienungsanleitung
Dormakaba
Nicht kategorisiert
RCI 3510LM
Lies die bedienungsanleitung für Dormakaba RCI 3510LM (2 Seiten) kostenlos online; sie gehört zur Kategorie Nicht kategorisiert. Dieses Handbuch wurde von 37 Personen als hilfreich bewertet und erhielt im Schnitt 4.8 Sterne aus 19 Bewertungen. Hast du eine Frage zu Dormakaba RCI 3510LM oder möchtest du andere Nutzer dieses Produkts befragen? Stelle eine Frage
Seite 1/2

INSTALLATION
RCI 3510LM
CABINET LOCK WITH LATCH MONITOR
ELECTRIC LOCK FOR SMALL ENCLOSURES
© 2020 dormakaba Canada Inc
www.dormakaba.us • Phone: 1.800.265.6630 • Fax: 1.800.482.9795 • E-mail: sales_RCI@dormakaba.comIS3510LM
PCN2016
R10-20GR-1
WIRING INSTRUCTIONS
NOTE: This lock requires some sort of external control.
1. Connecting wire must be of sufficient gauge to prevent line loss.
The 3510LM Cabinet Lock operates on either 12 or 24 VAC/DC
For 12 volt operation: connect a wire jumper from terminal 1 to 2 and also from terminal 3 to 4.
For 24 volt operation: connect one wire jumper from terminal 2 to 3.
2. With voltage jumpers installed, connect the positive (+) lead from the power supply to terminal 1.
Connect the negative(-) lead from the power supply to terminal 4.
For DC voltage, the supplied diode must be connected across terminals 1 and 4.
For AC voltage, terminal 1 and 4 connections are not polarity conscious. The diode is not required.
3 . The latch monitor feature indicates whether the door is closed/locked or open/unlocked.
The monitor switch contacts are rated 1 Amp @ 25V maximum.
Connect terminals 5 or 6 and 7 to suit N/O or N/C monitor requirements.
LM FEATURE
++
_ _
LATCH MONI R SWITCHTO
OUTPUT CONTACTS RATED
1 AM @ 25VP
12V JUMPER
CONNECTION
24V JUMPER
CONNECTION
+
-
Operating Voltage 12VDC 12VAC 24VDC 24VAC
Amps 0.25A 0.25A 0.12A 0.12A

MOUNTING INSTRUCTIONS
1. Two symbols are located on the latch that define fail locked or fail unlocked.
To set lock mode, align the latch symbol with the arrow on the lock.
Make sure to use the fail unlocked position for initial mounting and alignment.
Without power, the fail locked mode cannot open.
2. Using the cut-out template, mount the locking unit to the fixed portion of the cabinet or drawer with the four
#6 x 1-1/4” PH SMS screws.
Typical installations are shown below.
The locking unit and latch must be aligned as shown.
3. Peel the yellow side of the adhesive tape and apply to the back of the latch.
Engage latch into the mounted locking unit in the fail locked position.un
Peel white side of adhesive tape.
Close and open cabinet door or drawer.
The latch will be attached in the correct location.
For fail unlocked, simply secure the latch with the
four #6 x 1/2” PH SMS screws.
For fail locked turn the latch 180˚ and secure.
WasherWasher
Swing (Cupboard) MountSlide (Drawer) Mount
Apply Adhesive
Tape Here
Latch
L
C
Fold along dotted line on
fixed edge for surface mount
30.5mm
10mm
4.5mm
48mm
4.3mm
21mm
5mm
42mm
32mm
Cut-Out Template
Mounting Examples
Correct Alignment
Incorrect mounting
Correct Mounting Correct Mounting Correct Mounting
Fail Unlocked
Power to Lock
Fail Locked
Power to Unlock
Produktspezifikationen
Marke: | Dormakaba |
Kategorie: | Nicht kategorisiert |
Modell: | RCI 3510LM |
Brauchst du Hilfe?
Wenn Sie Hilfe mit Dormakaba RCI 3510LM benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten
Bedienungsanleitung Nicht kategorisiert Dormakaba
22 August 2024
22 August 2024
22 August 2024
21 August 2024
21 August 2024
21 August 2024
21 August 2024
21 August 2024
21 August 2024
21 August 2024
Bedienungsanleitung Nicht kategorisiert
- Vroomshoop
- Alfen
- NGS
- Winegard
- Ravanson
- Digi
- Elro
- Maxcom
- Dorman
- Cosina
- Medivon
- RCBS
- Grunkel
- Meridian
- Ditek
Neueste Bedienungsanleitung für -Kategorien-
17 Juni 2025
17 Juni 2025
17 Juni 2025
17 Juni 2025
17 Juni 2025
17 Juni 2025
17 Juni 2025
17 Juni 2025
17 Juni 2025
17 Juni 2025