Enda ET2411 Bedienungsanleitung
Enda Thermostat ET2411
Lies die bedienungsanleitung für Enda ET2411 (2 Seiten) kostenlos online; sie gehört zur Kategorie Thermostat. Dieses Handbuch wurde von 42 Personen als hilfreich bewertet und erhielt im Schnitt 4.5 Sterne aus 21.5 Bewertungen. Hast du eine Frage zu Enda ET2411 oder möchtest du andere Nutzer dieses Produkts befragen? Stelle eine Frage
Seite 1/2

ENDA2411 ON/OFF HEAT CONTROLLER ET
SET
°C
SET
ET2411
ENDA
°F
C1
230V AC +% -%, 50/60Hz 24V AC %1020or12//DC 10
Max.3 VA
Power connector : 2.5mm² screw-terminal, Signal connector : 1,5mm² screw-terminal conenction.
EN 61326-1 : 2013 (Performance criterion B is satisfied for EN 61000-4-3)
EEPROM ( 10 )Min.years
Max. 100ohm
EN 61010-1: 20 (Pollution degree 2, overvoltage category II) 10
12 bit , sampling time.resolution100ms
Max. 2000m
Do not use the device in locations subject to corrosive and flammable gasses.
Max. humidity 80% for temperatures up to 31°C decreasing linearly to 50% relative humidity at 40°C.
0 ... +50 /
-25... +70
°C°Cwithout icing()
According to EN60529; Front panel: IP65 Rear panel : IP20
SalceRange
Accuracy
EN 60751
-...0 °C -76.0...302.0°F60.015.0
± 1% (for full scale) ±
1Digit
Supply
HOUSING
Housing Type
Dimensions
Weight
Enclosure Materials
CONTROL
ontrolCType
Control Algorithm
A/DConverter
Hysteresis
INPUT
Height
Ambient/Storage temperature
Relative Humidity
Protection Class
Input Type
NTC Sensor Typ 103AT-2
at 25 °C - 10 kOhm
77mm
61mm
5mm
2
Connection
Cable
Panel
Rubber
Packing
71,5mm
1
For 5A Models : 250V AC, 5A (resistive load), NO control output.
For 8A Models : 250V AC, 8A (), NO and NC control output.resistive load
For 16A Models : 250V AC, 16A (), NO control output.resistive load
For 5A Models : 5.Switching for no-load operation; 100.000 switching for 5A resistive load at250VAC. Mio.
OUTPUT
Life Expectancy for Relay
C1 Output
Thank you for choosing ON/OFF Heat Controller.ENDA ET2411
Read this document carefully before using this device. The guarantee will be expired by device
demages if you don't attend to the directions in the user manual. Also we don't accept any
compensations for personal injury, material damage or capital disadvantages.
Holding screw
0.4-0.5Nm.
Equipment is protected throughout
by DOUBLE INSULATION
5
6
SUPPLY:
NOTE:
184-253V AC
50/60Hz 3VA
Line
Neutral
230V AC
Supply
Switch
Note:
Cable size: 1,5mm²
Fuse
F 100 mA
250V AC
Fuse should
be connected
1) Mains supply cords shall meet the requirements of
IEC 60227 or IEC 60245.
2) In accordance with the safety regulations, the power
supply switch shall bring the identification of the
relevant instrument and it should be easily
accessible by the operator.
TECHNICAL SPECIFICATIONS
ENVIRONMENTAL CONDITIONS
ELECTRICAL CHARACTERISTICS
Power onsumptionC
Wiring
Indicator
EMC
Safety Requirements
Data Retention
Line Resistance
4 digits, 12.5mm, 7 segment red LED
Singleand alarm .-setpoint control
Adjustable between 0.1 and 20.0°C/F.
according to DIN 43 700.Suitable for flush-panel mounting
51W77xH3xD6mm
Approx. 215g (A)fter packing
Self extinguishing plastics
While cleaning the device, solvents (thinner, benzine, acid etc.) or corrosive materials must not be used.
Dimensions
For removing mounting clamps:
-Push the flush-mounting clamp
in direction as shown in the
figure below.Then,pull
out the clamp in direction .
1
2
Depth
Flush mounting
clamp
Flush mounting
clamp
Panel cut-out
Note:
1)Panel thickness should
be maximum 7mm.
2)If there is no 60mm free
space at the back side of
the device,it would be
difficult to remove it from
the panel.
t
ENDA ET2411is intended for installation within control panels. Make sure that the device is used only for
intended purpose. The shielding must be grounded on the instrument side. During an installation, all of the
cables that are connected to the device must be free of electrical power. The device must be protected against
inadmissible humidity, vibrations, severe soiling. Make sure that the operation temperature is notexceeded.
All input and output lines that are not connected to the supply network must be laid out as shielded and twisted cables.
These cables should not be close to the power cables or components. The installation and electrical connections must
be carried out by a qualified staff and must be according to the relevant locally applicable regulations.
For 8A Models : 30.Switching for no-load operation; 300.000 switching for 8A resistive load at 250VAC. Mio.
For 16A Models : 30. Switching for no-load operation; 100.000 switching for 16A resistive load at250VAC. Mio.
ET2411-230-08
DIGITAL THERMOSTAT
250V AC 8A
RESISTIVE LOAD
8680407715299
Made in Turkey
C1
123456
789
10
11
12
NTC
SN: XXXXXXXXX
ENDAINDUSTRIAL ELECTRONICS
ET2411-230-16
DIGITAL THERMOSTAT
250V AC 16A
RESISTIVE LOAD
8680407715367
Made in Turkey
C1
123456
789
10
11
12
NTC
SN: XXXXXXXXX
ENDAINDUSTRIAL ELECTRONICS
ET2411-SM-05
DIGITAL THERMOSTAT
250V AC 5A
RESISTIVE LOAD
8680407715350
Made in Turkey
C1
123456
789
10
11
12
NTC
SN: XXXXXXXXX
ENDAINDUSTRIAL ELECTRONICS
ET2411-230-08
DIGITAL THERMOSTAT
250V AC 8A
RESISTIVE LOAD
8680407715299
Made in Turkey
C1
123456
789
10
11
12
NTC
SN: XXXXXXXXX
ENDAINDUSTRIAL ELECTRONICS
Order Code : ET2411 - -
1
2
1 - Supply Voltage
230...230V AC
24........24V AC
.....
0 /DC
012........12V AC/DC
SM.........7-24VAC/9-30VDC
2 - Relay Current Selection
05.....5A Re
08.....8A
lay Output
Relay Output
16...16A Relay Output
SET
°C
SET
ET2411
ENDA
°F
C1
- 77 x 35mm sized.
- Single NTC sensor input.
- Zero point input shift.
- Selectable heating or cooling control for C1 relay output.
- Upper and lower setpoint limits can be adjusted.
- Temperature unit can be selected as °C or °F.
- CE marked according to European Norms.
- Selectable heating or cooling control.
- In the case of sensor failure, relay state can be set to ON or OFF.
english
SURANIndustrieelektronik
Dettinger Str. 9
D-72160 Horb a.N.
Tel.: +49 (0)7451 / 625 617 E-mail : info@suran-elektronik.de
Fax: +49 (0)7451 / 625 0650 Internet : www.suran-elektronik.de
up to date: 25.03.2019, modification reserved and can be change any time previous notice !
ET2411-E-25032019
1. /2
R HS
Konform
Produktspezifikationen
| Marke: | Enda |
| Kategorie: | Thermostat |
| Modell: | ET2411 |
Brauchst du Hilfe?
Wenn Sie Hilfe mit Enda ET2411 benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten
Bedienungsanleitung Thermostat Enda
4 September 2024
3 September 2024
3 September 2024
3 September 2024
3 September 2024
3 September 2024
Bedienungsanleitung Thermostat
Neueste Bedienungsanleitung für -Kategorien-
19 Januar 2026
14 Januar 2026
14 Januar 2026
13 Januar 2026
2 Januar 2026
29 Dezember 2026
27 Dezember 2025
25 Dezember 2025
23 Dezember 2025
23 Dezember 2025