Hikvision DS-PDSK-P Bedienungsanleitung
Hikvision Alarmanlage DS-PDSK-P
Lies die bedienungsanleitung für Hikvision DS-PDSK-P (2 Seiten) kostenlos online; sie gehört zur Kategorie Alarmanlage. Dieses Handbuch wurde von 55 Personen als hilfreich bewertet und erhielt im Schnitt 4.6 Sterne aus 28 Bewertungen. Hast du eine Frage zu Hikvision DS-PDSK-P oder möchtest du andere Nutzer dieses Produkts befragen? Stelle eine Frage
Seite 1/2

Specificaon
H2
H1
H3
H4
H5
H1 - Pulse Count
H2 - Pulse Count
H3 - LED
H4 - Sensivity
H5 - Latch
3.2
3.3
3.4
3.5
MaterialConcreteWoodFixed Window Frame
1.0m2.5m2.5m
H1
H2
H3
H4
H5
H1
H2
H3
H4
H5
Remove the jumper from the H5 (or put on just one pin so that the jumper is
not lost) to acvate the latching feature. If this feature is acvated and the
sensor is triggered, the LED on the sensor will stay on in order to display that it
has been acvated. To reset, the power must be removed from the device.
If the sensor detects “gross aack” (a vibraon higher than the calibrated sensivity), it will
override the pulse count and go directly into alarm.
108mm
30mm
22mm
37.5g
3.2 Sengs - Pluse Count
3.4 Sengs - Sensivity3.5 Sengs - Latch4 Wiring
Dimension
3.3 Sengs - LED
2 Installaon1 Component
3.1 Sengs - Jumper
Note: The stated values are typical. It is advised that
practical testing is performed before installation to verify
the operation. In some environments, these values may
differ from stated.
H1
H2
H3
H4
H5
Each me the pulse count seng is changed, the LED will flash the appropriate number of mes
to indicate which seng is selected. It will verify this by indicang the pulse count seng 3
mes, pausing between each verificaon.
a. Screw Cover
d. Light Pipe
e. PCB
b. Screw
f. Rear Panel
Wired Shock Detector
0s
0s
0s
0s
0.5s
0.5s
0.5s
0.5s
1s
1s
1s
1s
1.5s
1.5s
1.5s
1.5s
2s
2s
2s
2s
a. Powering up
b. Vibraon detected
c. Device triggered
d. Gross acvaon
Flash on and off
Flash once
Flash once → Off
Flash once → Latch (Remove H5)
Flash once → Off
Flash once → Stay on (Remove H5)
LED
a. High Sensivityb. Low Sensivity c. Increased. Decrease
Material and Mounng Posion
H1
H2
H3
H4
H5
Pluse Count
H1 H2 Pluse
1
2
4
6
a. Alarm Control Panel
b. Sensor
(1) Normally Closed
ZONE2
COM
ZONE1
COM
+
-
TAMPERALARM
-+
(2) Double End of Line Wiring
a. Alarm Control Panel
b. Sensor
Wiring Example:
1. Normal: 2.2 K
2. Alarm: 4.4 k
3. Tamper: Infinite
ZONE2
COM
ZONE1
COM
+
-
TAMPERALARM
-+
1
3
4
2
UD21449B
c. Front Panel
2.2K2.2K
SensorPiezoelectric sensor
SensivityPotenometer Adjustment
Tamper switchSupport
Intelligent algorithmSupport
Alarm outputNormally closed
LEDBlue (alarm)
Nominal voltage9 to 16 VDC
Nominal current30 mA
Storage temperature-20 °C to 60 °C (-4 °F to 140 °F)
Operang temperature-10 °C to 55 °C (14 °F to 131 °F)
Operang humidity10% to 90%
InstallaonWall-mounng
Dimension108 mm × 30 mm × 22 mm
Weight37.5g
FCC statements: This device complies with part 15 of the FCC Rules.Operaon is subject to the following
two condions:(1)this device may not cause harmful interface,and (2)this device must accept any
interference received,including interference that may cause undesired operaon
FCC Informaon
Please take aenon that changes or modificaon not expressly approved by the party responsible for compliance could
void the user’s authority to operate the equipment.
FCC compliance: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant
to part 15 of the FCC Rules. These limits are designed to provide reasonable protecon against harmful interference in a
residenal installaon. This equipment generates, uses and can radiate radio frequency energy and, if not installed and
used in accordance with the instrucons, may cause harmful interference to radio communicaons. However, there is no
guarantee that interference will not occur in a parcular installaon. If this equipment does cause harmful interference to
radio or television recepon, which can be determined by turning the equipment off and on, the user is encouraged to try
to correct the interference by one or more of the following measures:
—Reorient or relocate the receiving antenna.
—Increase the separaon between the equipment and receiver.
—Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
—Consult the dealer or an experienced radio/TV technician for help
FCC Condions
This device complies with part 15 of the FCC Rules. Operaon is subject to the following two condions:
1. This device may not cause harmful interference.
2. This device must accept any interference received, including interference that may cause undesired operaon.
Produktspezifikationen
| Marke: | Hikvision |
| Kategorie: | Alarmanlage |
| Modell: | DS-PDSK-P |
Brauchst du Hilfe?
Wenn Sie Hilfe mit Hikvision DS-PDSK-P benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten
Bedienungsanleitung Alarmanlage Hikvision
13 Januar 2026
2 Januar 2026
11 Oktober 2025
3 Oktober 2025
21 September 2025
21 September 2025
21 September 2025
21 September 2025
21 September 2025
21 September 2025
Bedienungsanleitung Alarmanlage
Neueste Bedienungsanleitung für -Kategorien-
18 Januar 2026
13 Januar 2026
9 Januar 2026
9 Januar 2026
5 Januar 2026
4 Januar 2026
1 Januar 2026
31 Dezember 2026
27 Dezember 2025
27 Dezember 2025