Lies die bedienungsanleitung für Hoshizaki HS-5462 (6 Seiten) kostenlos online; sie gehört zur Kategorie Nicht kategorisiert. Dieses Handbuch wurde von 13 Personen als hilfreich bewertet und erhielt im Schnitt 4.8 Sterne aus 7 Bewertungen. Hast du eine Frage zu Hoshizaki HS-5462 oder möchtest du andere Nutzer dieses Produkts befragen? Stelle eine Frage

Seite 1/6
1
2A9185-011
Hoshizaki Optional Heated Overow Drain Pan Kit
HS-5462
For Use with Steelheart Refrigerator Series Upright Models
Installation Instructions
Check to ensure that all parts are included:
Index
No.Description
NumberQty
1Heated Overow Drain Pan 3B0185-011
2Heated Overow Drain Pan Bracket3B0247-011
3Drain Elbow (1 and 2)4A1017-012
4Vinyl Hose A (15 1/8 in. (385 mm))7725-19231
5Vinyl Hose B (68 in. (1727 mm))7725-19231
6Wire Harness (8 ft. (2 m))4A6586-011
7Self-Drilling Hex Screw7B03I12108
8437618-018Nylon Tie Mount
98911-02008Nylon Tie
10Wire Clamp4A0809-031
11Bushing428394-012
12Junction Box3B0361-011
13Wiring Label3B0115-011
WARNING
The appliance should be serviced only by qualied service personnel to reduce the risk of death, electric
shock, serious injury, or re.
• No installation or service should be undertaken until the technician has thoroughly read these instructions.
Failure to follow these instructions will adversely affect safety, performance, component life and warranty
coverage, and may result in costly water damage.
To reduce the risk of electric shock, do not touch the plug with damp hands. Move the power switch to the
"OFF" position, then unplug the appliance from the electrical outlet before servicing.
Installation Instructions - Repeat these instructions for second kit on 3-section models
1) Unplug the appliance from the electrical outlet.
2) Move the appliance out to access the rear of the appliance.
3) Remove the front, control, right side, and top panels from the appliance. See Fig. 1.
4) Remove the nylon tie connecting the existing drain hose to the evaporator drain pipe. Remove the existing drain hose and discard.
See Fig. 2.
Fig. 1
Model Shown: R1A-FS
Top Panel
Right
Side Panel
Existing
Drain Hose
Nylon Tie
Fig. 2
Front Panel
Control Panel
Evaporator
Drain Pipe