Hoshizaki HWR96A-D Bedienungsanleitung
Hoshizaki Kühlschrank HWR96A-D
Lies die bedienungsanleitung für Hoshizaki HWR96A-D (2 Seiten) kostenlos online; sie gehört zur Kategorie Kühlschrank. Dieses Handbuch wurde von 8 Personen als hilfreich bewertet und erhielt im Schnitt 4.9 Sterne aus 5 Bewertungen. Hast du eine Frage zu Hoshizaki HWR96A-D oder möchtest du andere Nutzer dieses Produkts befragen? Stelle eine Frage
Seite 1/2

HWR40/68/96A-D
09/07/16
Item # 13189
c. reserves the right to change
specifications without notice.
*AutoCad available on KCL
Item #
Project:
Qty:
• Stainless steel interior and exterior top, front and sides
• EverCheck solid state digital control system with visual alarms
• Entire cabinet is insulated with 2 3/8" CFC free foamed in place polyurethane
• Each drawer accommodates (2) 12” x 20” x 6” deep pans (pans by others)
• Drawer fronts are stainless steel interior and exterior
• Drawer slides are 14 gauge stainless steel with delrin nylon rollers
• Drawers have a 250 lb dynamic load rating
• Cabinet drawer perimeter heaters provide condensation control in high humidity environments
• Epoxy coated evaporator coil
• Front breathing with Zero clearance requirements
• Cartridge-style refrigeration system is easily removed from main unit
• Defrost is time initiated temperature terminated
• Hinged, louvered front panel for easy access to controller
• Removable stainless steel end panel for access to refrigeration system
• Removable, cleanable refrigeration system Air Filter
• Energy efficient automatic hot gas condensate evaporator
• (1) Epoxy coated wire shelf per section
• Stainless steel shelf supports adjustable on 1” centers
• 4" heavy duty platform casters (two with brakes)
• Three years parts and labor warranty
• Five year compressor warranty
• 8 ft. cord and plug
HWR-A-DDimensions
W x D x H
1 Section - 40.25” x 32.3” x 39.9”*
2 Section - 68” x 32.3” x 39.9”*
3 Section - 95.8” x 32.3” x 39.9”*
*
with 6” casters
Electrical/Refrigeration
Voltage- 115/60/1
H
ACR Breaker- 15.0
Electrical Connection- 5-15P
(NEMA)
Voltage Range- 104-126
Ambient Temp. Range- 45˚-100˚F
Control Setpoint Range- +21˚ to +53˚F
*RefrigerantR-134a
Warranty
Valid in United States, Canada, Puerto Rico,
and U.S. Territories. Contact factory for
warranty in other countries.
• Three Year - Parts & Labor on entire
machine.
• Five Year- Parts on: Compressor.
Options
• 6” Legs
• 6” Casters
• Bullnose top (front & rear)
• Additional epoxy shelves
Dimensions / Capacity
Electrical & Refrigeration Data
Model #One Section
HWR40A-D
Two Section
HWR68A-D
Three Section
HWR96A-D
InteriorStorageCapacity(CF)8.5 ft
3
18.8 ft
3
29.1 ft
3
Overall Width x Depth40.25” x 32.3” 68” x 32.3” 95.8” x 32.3”
Height (including 6” casters)39.9”39.9”39.9”
Drawer Fully Open (in)58.1” 58.1” 58.1”
Drawer Opening Width x Height 22.5” x 9.9”22.5” x 9.9”22.5” x 9.9”
Pan Capacity (12” x 20” x 6” DP Pans)4812
Crated Shipping Weight375 lbs554 lbs734 lbs
Crated Height x Width x Depth43.25” x 44.25” x 36.25”43.25” x 72” x 36.25”43.25” x 99.75” x 36.25”
Model #One Section
HWR40A-D
Two Section
HWR68A-D
Three Section
HWR96A-D
Amperage
5.05.06.0
Energy Consumption (kwh/day)
3.24.96.0
Heat Rejection (BTU/Hr.)
449695852
Approx. Nominal Compres. BTU/HR(HP)
1442 (1/5HP)1442 (1/5HP)2010 (1/4HP)
HWR40/68/96A-D
Professional Series Worktop Refrigerators
© HOSHIZAKI AMERICA, INC.
618 Hwy. 74 S., Peachtree City, GA 30269
TEL 800-438-6087
FAX 800-345-1325
www.hoshizaki.com
Produktspezifikationen
| Marke: | Hoshizaki |
| Kategorie: | Kühlschrank |
| Modell: | HWR96A-D |
Brauchst du Hilfe?
Wenn Sie Hilfe mit Hoshizaki HWR96A-D benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten
Bedienungsanleitung Kühlschrank Hoshizaki
12 September 2025
12 September 2025
12 September 2025
12 September 2025
12 September 2025
12 September 2025
12 September 2025
12 September 2025
12 September 2025
12 September 2025
Bedienungsanleitung Kühlschrank
Neueste Bedienungsanleitung für -Kategorien-
22 Januar 2026
21 Januar 2026
21 Januar 2026
21 Januar 2026
21 Januar 2026
21 Januar 2026
21 Januar 2026
21 Januar 2026
21 Januar 2026
21 Januar 2026