IFM PC3504 Bedienungsanleitung
IFM
Nicht kategorisiert
PC3504
Lies die bedienungsanleitung für IFM PC3504 (5 Seiten) kostenlos online; sie gehört zur Kategorie Nicht kategorisiert. Dieses Handbuch wurde von 10 Personen als hilfreich bewertet und erhielt im Schnitt 4.5 Sterne aus 5.5 Bewertungen. Hast du eine Frage zu IFM PC3504 oder möchtest du andere Nutzer dieses Produkts befragen? Stelle eine Frage
Seite 1/5

Installation Instructions
Electronic pressure sensor
for industrial applications
PC3504
704967 / 00 12 / 2010
UK

2
1 Safety instructions
• Please read this document prior to installing the unit. Ensure that the product is
suitable for your application without any restrictions.
• If the operating instructions or the technical data are not adhered to, personal
injury and/or damage to property may occur.
• Please check for all applications that the product materials (see Technical data)
are compatible with the media to be measured.
For the scope of validity cULus:
The device shall be supplied from an isolating transformer having a secondary
Listed fuse rated either
a) max 5 amps for voltages 0~20 Vrms (0~28.3 Vp) or
b) 100/Vp for voltages of 20~30 Vrms (28.3~42.4 Vp).
2 Function and features
The pressure sensor detects the system pressure and converts it into an analogue
output signal (4 ... 20 mA).
2.1 Applications
• Type of pressure: relative pressure
Order no. Measuring range Permissible
overload pressure
Bursting
pressure
bar PSI bar PSI bar PSI
PC3504 0...16 0...232 25 362 300 4351
MPa = bar ÷ 10 / kPa = bar × 100
Contents
1 Safety instructions ................................................................................................2
2 Function and features ...........................................................................................2
2.1 Applications ....................................................................................................2
3 Installation ............................................................................................................3
4 Electrical connection.............................................................................................3
5 Scale drawing .......................................................................................................4
6 Technical data .......................................................................................................5

3
UK
Static and dynamic overpressures exceeding the indicated overload pres-
sure are to be avoided by taking appropriate measures.
The indicated bursting pressure must not be exceeded. Even if the burst-
ing pressure is exceeded only for a short time, the unit can be destroyed.
NOTE: Risk of injury!
3 Installation
Before mounting and removing the sensor, make sure that no pressure is
applied to the system.
► Insert the unit in a G¼ process connection.
► Tighten firmly. Tightening torque: max. 25 Nm.
4 Electrical connection
The unit must only be connected by an electrician.
The national and international regulations for the installation of electrical
equipment must be observed.
Voltage supply to EN50178, SELV, PELV..
► Disconnect power.
► Connect the unit as follows:
Core colours of ifm sockets:
1 = BN (brown), 2 = WH (white), 3 = BU (blue), 4 = BK (black),
n.c. = not connected.
Produktspezifikationen
Marke: | IFM |
Kategorie: | Nicht kategorisiert |
Modell: | PC3504 |
Brauchst du Hilfe?
Wenn Sie Hilfe mit IFM PC3504 benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten
Bedienungsanleitung Nicht kategorisiert IFM
25 Juli 2025
25 Juli 2025
25 Juli 2025
25 Juli 2025
21 Juli 2025
20 Juli 2025
20 Juli 2025
20 Juli 2025
20 Juli 2025
20 Juli 2025
Bedienungsanleitung Nicht kategorisiert
- Zempire
- Roba
- Modbap Modular
- Grunkel
- Gitzo
- Grandeur
- Rotolight
- Crystal Quest
- Fluke
- Simrig
- Aarke
- ProDAD
- Graupner
- Bright Starts
- Chuango
Neueste Bedienungsanleitung für -Kategorien-
30 Juli 2025
30 Juli 2025
30 Juli 2025
30 Juli 2025
30 Juli 2025
30 Juli 2025
30 Juli 2025
30 Juli 2025
30 Juli 2025
30 Juli 2025