Lies die bedienungsanleitung für IFM VTV121 (4 Seiten) kostenlos online; sie gehört zur Kategorie Nicht kategorisiert. Dieses Handbuch wurde von 14 Personen als hilfreich bewertet und erhielt im Schnitt 4.7 Sterne aus 7.5 Bewertungen. Hast du eine Frage zu IFM VTV121 oder möchtest du andere Nutzer dieses Produkts befragen? Stelle eine Frage

Seite 1/4
Operating instructions
Vibration transmitter
VTV121
80226822/00 01/2015
UK
UK
UK
UK
UK
2
Symbols used
Instruction
Important note
Non-compliance can result in malfunctions or interference.
1 Safety instructions
Please read the product description prior to set-up of the unit. Ensure that the
product is suitable for your application without any restrictions.
The unit conforms to the relevant regulations and EC directives.
Improper or non-intended use may lead to malfunctions of the unit or to
unwanted effects in your application.
That is why installation, electrical connection, set-up, operation and
maintenance of the unit must only be carried out by qualified personnel
authorised by the machine operator.
2 Functions and features
The vibration transmitter detects the vibration in the system (measured / evaluated
physical unit = vibration velocity). This is converted into an analogue signal at the
current output.
3 Installation
Mount only in a thick housing wall
(e.g. transport thread).
Ensure that the signal direction is
correct.
Ensure a safe vibration transmissi-
on and allow no elastic intermediate
layers.
3
UK
Select either the ¼“-28 UNF / M8
(2) or the ¼“-28 UNF (3) threaded
adapter and insert into the unit (1).
Both adapters are supplied.
Tighten using a 3 mm Allen key.
Tightening torque 8 Nm.
Drill and tap a hole at the mounting
location:
- M8 hole / depth min. 10 mm
- or ¼“ UNF hole / depth min.
13 mm.
Tighten the sensor with a tightening torque of 8 Nm.
4 Electrical connection
The unit must be connected by a qualified electrician. The national and
international regulations for the installation of electrical equipment must be
adhered to.
M12
4
1 2
3
L+
L
1
2
Pin 1: L+ (9.6...32 V DC)
Pin 2: 4...20 mA
Pin 3: not used (n.c.)
4.1 Measuring range
veff mm/s 0...50
Iout mA 4...20
Frequency range Hz 10...1000