Lies die bedienungsanleitung für Intermatic AT2-5BS4U-BGI (2 Seiten) kostenlos online; sie gehört zur Kategorie Nicht kategorisiert. Dieses Handbuch wurde von 11 Personen als hilfreich bewertet und erhielt im Schnitt 4.7 Sterne aus 6 Bewertungen. Hast du eine Frage zu Intermatic AT2-5BS4U-BGI oder möchtest du andere Nutzer dieses Produkts befragen? Stelle eine Frage
Seite 1/2

PARRANGEDESCRIPTION
SCL1°C;
2°C;
°F
Readout scale.
1°C (only with =SN4): measuring range -50/-9.9 … 19.9/80°CINP
2°C : measuring range -50 … 120°C
°F : measuring range -55 … 240°F
Caution: upon changing the value, it is then necessary to reconfigure the parameters relevant SCLabsolutely
to the absolute and relative temperatures (, , SPLSPHSP, , ALAAHA, etc..)
SPL-50..SPHMinimum limit for SP setting (-20°C)
SPHSPL.120°Maximum limit for SP setting (5°C)
SPSPL... SPHSetpoint (value to be maintained in the room). (-18°C)
C-HREF; HEARefrigerating (REF) or Heating (HEA) control mode
HYS1...10°OFF/ON thermostat differential (3°C)
OFF
ON
SPSP+HY
T[°]
OFF
ON
SPSP-HY
T[°]
CRT0...30minCompressor rest time. The output is switched on again after CRT minutes have elapsed since the previous
switchover. We recommend to set CRT=03 with HYS<2.0°. (3)
CT10...30min
Thermostat output run when probe T1 is faulty. With
CT1
=0 the output will always remain OFF.
(3)
CT20...30min
Thermostat output stop when probe T1 is faulty. With
CT2
=0 and
CT1
>0 the output will always be ON.
Example:
CT1
=4,
CT2
= 6: In case of probe T1 failure, the compressor will cycle 4 minutes ON and 6 minutes
OFF.
(6)
CSD0..30minCompressor stop delay after the door has been opened (active only if DS=YES). (1)
DFR0... 24(1/24h)Defrost frequency expressed in cycles/24 hours. (3)
DLI-50...120°Defrost end temperature. (6°C)
DTO1...120minMaximum defrost duration. (20)
DTYOFF;
ELE;
GAS
Defrost type
OFF: off cycle defrost (Compressor and Heater OFF).
ELE: electric defrost* (Compressor OFF and Heater ON).
GAS: hot gas defrost* (Compressor and Heater ON).
* The defrost output is active if only OAU=DEF.
DRN0...30minPause after defrost (evaporator drain down time). (3)
DDY0...60minDisplay during defrost. If DDYDDY=0 during defrost the temperature continues to be displayed. If > 0, during
defrost the display shows DEF, when defrost is over REC is displayed during DDY minutes. (10)
FIDNO/YESFans active during defrost. (NO)
FDD-50...120°Evaporator fan re-start temperature after defrost. (-2°C)
FTC(NO) NO/YESOptimised fan control enabling. With FTC = NO the fans remain on all the time
ON
OFF
FT3FT2FT2FT3FT1
CMP OFFCMP ONCMP ON
FT10...180secFan stop delay after compressor stop. See Fig. 2. (30)
FT20...30minTimed fan stop. With FT2=0 the fans remain on all the time. (3)
FT30...30minTimed fan run. With FT3=0, and FT2 > 0, the fans remain off all the time. (1)
ATMNON;
ABS;
REL
Alarm threshold management.
NON: all temperature alarms are inhibited (the following parameter will be ADO).
ABS: the values programmed in and ALAAHA represent the real alarm thresholds.
REL: the values programmed in and are alarm differentials referred to and ALRAHRSPSP+HY.
OFF
ON
SPSP+HYS+AHRSP-ALR
T[°]
OFF
ON
SP-HYS-
ALR
SP+AHR
T[°]
SP
ALA-50... 120°Low temperature alarm threshold. (-50°C)
AHA-50... 120°High temperature alarm threshold. (120°C)
ALR-12... 0°Low temperature alarm differential. With =0 the low temperature alarm is excluded. ALR(0°C)
AHR0... 12°High temperature alarm differential. With AHR=0 the high temperature alarm is excluded. (0°C)
ATD0... 120minDelay before alarm temperature warning. (30)
ADO0... 30minDelay before door open alarm warning. (5)
ACC0...52
weeks
Condenser periodic cleaning. When the compressor operation time, expressed in weeks, matches the ACC
value programmed, “CL” flashes in the display. With ACC=0 the condenser cleaning warning is disabled. (0)
IISMNON;
MAN;
Switchover mode to second parameter set
NON: inhibition to use the second parameter group (the following parameter will be SB).
MAN: button switches the two parameter groups over.
IISL-50...IISHMinimum limit for IISP setting. (-5°C)
IISHIISL...120°CMaximum limit for IISP setting. (5°C)
IISPIISL... IISHSetpoint in mode 2. (0.0°C)
IIHY1...10°OFF/ON differential in mode 2. (3°C)
IIFTNO/YESOptimised fan control enabling in mode 2. (NO)
IIDF0...99hoursDefrost timer set to start a defrost in mode 2. (0)
SBNO/YES
Stand-by button enabling. (YES)
DSNO/YESDoor switch input enabling (closed when door is closed). (NO)
LSMNON;
MAN;
DOR
Light control mode
NON : light output not controlled.
MAN : light ouput controlled through button (if OAU=LGT).
DOR : light ouput switched on when door is opened (if OAU=LGT).
OAUNON;
0-1;
DEF;
LGT;
AL0;
AL1
AUX output operation.
NON : output disabled (always off).
0-1 : the relay contacts follow the on/standby state of controller.
DEF : output programmed for defrost control.
LGT : output enabled for light control.
AL0 : contacts open when an alarm condition occurs.
AL1 : contacts make when an alarm condition occurs.
INPSN4; ST1
Temperature sensor selection. With
INP
=
SN4,
the probes must be the
Intermatic
models SN4..; with
INP
=
ST1, the probes must be the
Intermatic
models ST1...
OS1-12.5..12.5°CProbe T1 offset. (0.0°C)
T2NO/YESProbe T2 enabling (evaporator). (YES)
OS2-12.5..12.5°CProbe T2 offset. (0.0°C)
TLD1...30 minDelay for minimum temperature (TLO) and maximum temperature (THI) logging. (5)
SIM0...100Display slowdown.(1)
ADR1...255AT2-5 address for PC communication. (1)
WIRING DIAGRAMS
16(5)A
TTL
T1
ComT2
7(2)A7(2)A
AUX
34512
7891110
Door
Switch
AT2-5BS4E-AG
L1
L2 / Neutral
230Vac
INSTALLATION
■Insert the controller through a hole measuring 71 mm x 29 mm.
■Make sure that electrical connections comply with the paragraph “wiring diagrams”. To reduce the effects of electromagnetic disturbance,
keep the sensor and signal cables well separate from the power wires.
■Fix the controller to the panel by means of the suitable clips, by pressingly gently; if fi tted, check that the rubber gasket adheres to the
panel perfectly, in order to prevent debris and moisture infi ltration to the back of the instrument.
■Place the probe T1 inside the room in a point that truly represents the temperature of the stored product.
■Place the probe T2 on the evaporator where there is the maximum formation of frost.
OPERATION
DISPLAY
During normal operation, the display shows either the temperature measured or one of the following indications:
DEFDefrost in progressHIRoom high temperature alarm
RECLORecovery after defrostRoom low temperature alarm
OFFController in stand-byE1Probe T1 failure
CLE2Condenser clean warningProbe T2 failure
DODoor open alarm
INFO MENU
The information available in this menu is:
T1TLOInstant probe 1 temperatureMinimum probe 1 temperature recorded
T2CNDInstant probe 2 temperatureCompressor working weeks
THIMaximum probe 1 temperature recordedLOCKeypad state lock
Access to menu and information displayed.
■Press and immediately release button .
■With button or select the data to be displayed.
■Press button to display value.
■To exit from the menu, press button or wait for 10 seconds.
Reset of THI, TLO, CND recordings
■With button or select the data to be reset.
■Display the value with button .
■While keeping button pressed, use button .
SETPOINT (display and modifi cation of desired temperature value)
■Press button for at least half second, to display the setpoint value.
■By keeping button pressed, use button or to set the desired value (adjustment is within the minimum and the maximum SPL
SPH limit).
■When button is released, the new value is stored.
STAND-BY
Button , when pressed for 3 seconds, allows the controller to be put on a standby or output control to be resumed (with SB=YES only).
KEYPAD LOCK
The keypad lock avoids undesired, potentially dangerous operations, which might be attempted when the controllers is operating in a public
place. In the INFO menu, set parameter =YES to inhibit all functions of the buttons. To resume normal operation of keypad, adjust setting LOC
so that LOC=NO.
DEFROST
Timed defrost.Defrosting starts automatically when necessary time has elapsed to obtain the defrosting frequency set with DFR. For
example, with =4 defrosting occurs once every 6 hours. The internal timer is set to zero when power is applied to the controller and at DFR
each subsequent defrost start. When the controller is put on a standby, the accumulated time count is “frozen” (is not incremented).
Manual defrost. Defrosting may also be induced manually by keeping the button pressed for 2 seconds.
Defrost type.Once defrost has started, Compressor and Defrost outputs are controlled according to the parameters DTY and OAU. The AUX
output is associated to defrost function with OAU=DEF exclusively.
Defrost termination.Defrost lasts as long as time DTObut, if the evaporator probe has been enabled (T2=YES) and temperature DLIis
achieved before this time elapses, defrost will be terminated in advance. Caution: if =HEA all defrost functions are inhibited; if DFR=0 C-H
the timed defrost function is excluded; during defrost, the high temperature alarm is inhibited.
CONFIGURATION PARAMETERS
■The setup menu is accessed by pressing button + for 5 seconds.
■With button or select the parameter to be modified.
■Press button to display the value.
■By keeping button pressed, use button or to set the desired value.
■When button is released, the newly programmed value is stored and the following parameter is displayed.
■To exit from the setup, press button or wait for 30 seconds.
Thank you for having chosen an Intermatic electronic product. Before installing the instrument, please read these instructions carefully to
ensure maximum performance and safety.
AT2-5 INSTRUCTIONS FOR USE
TECHNICAL DATA
Power supply
AT2-5…E 230Vac±10%, 50/60Hz, 3W
AT2-5…U 120Vac±10%, 50/60Hz, 3W
AT2-5…D 12Vac/dc±10%, 3W
Relay outputs
AT2-5.Q… Compressor 12(5)A 240vac
AT2-5.S… Compressor 16(5)A 240vac
Evaporator fans 7(2)A 240vac
Auxiliary loads 7(2)A 240vac
AT2-5.Q… maximum total current 12A
AT2-5.S… maximum total current 16A
Inputs
NTC 10K�@25°C, part No. SN4...Intermatic
PTC 1000�@25°C, part No. ST1…Intermatic
Measuring Range
-50…120°C, -55…240°F
-50 / -9.9 … 19.9 / 80°C (NTC10K only)
Measuring accuracy
<0.5°C within the measurement range
Operating conditions
-10 … +50°C; 15%...80% r.H.
CE – UL (Approvals and Reference Norms)
EN60730-1; EN60730-2-9;
EN55022 (Class B);
EN50082-1
UL 60730-1A
Front protection
IP55
158--01982
Thermostat output
Fan output
Auxiliary output
Activation of 2nd parameter set
Alarm
Info / Setpoint button
Manual defrost / Decrease button
Increase / manual activation button
Exit / Stand-by button
Fig.1 — Front panel
■Disconnect power at the circuit breaker(s) or disconnect switch(es) before installing or servicing.
■More than one circuit breaker or disconnect switch may be required to de-energize the equipment before servicing.
■Installation and/or wiring must be in accordance with National and Local Electrical Code requirements.
■The device shall be installed in compliance with the enclosure, mounting, spacing and segregation requirements of the ultimate enclosure.
WARNING
Risk of Fire or Electric Shock
Temperature alarm with relative thresholds,
refrigerating control (ATM=REL, C-H=REF).
Refrigerating control (C-H=REF )
Fig. 2 Optimised fan control (FTC=YES)
Temperature alarm with relative thresholds,
heating control (=HEA). ATM=REL, C-H
Heating control (C-H=HEA)
DESCRIPTIONINDICATIONS
7777 Winn Road
Spring Grove, IL 60081
Intermatic Customer Service:
815-675-7000
www.intermatic.com
INSTRUCTIONS FOR USE
AT2-5
INSTRUCTIONS FOR USE
AT2-5
EN
MODE D’EMPLOI
FR
0L0025R00-03
Produktspezifikationen
| Marke: | Intermatic |
| Kategorie: | Nicht kategorisiert |
| Modell: | AT2-5BS4U-BGI |
Brauchst du Hilfe?
Wenn Sie Hilfe mit Intermatic AT2-5BS4U-BGI benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten
Bedienungsanleitung Nicht kategorisiert Intermatic
5 November 2025
5 November 2025
4 September 2025
3 September 2025
20 August 2025
20 August 2025
4 August 2025
2 August 2025
2 August 2025
2 August 2025
Bedienungsanleitung Nicht kategorisiert
Neueste Bedienungsanleitung für -Kategorien-
21 Januar 2026
21 Januar 2026
21 Januar 2026
21 Januar 2026
21 Januar 2026
21 Januar 2026
21 Januar 2026
21 Januar 2026
21 Januar 2026
21 Januar 2026