Intermatic DDFM Bedienungsanleitung
Seiten 18 Schalter
Lies die Bedienungsanleitung für Intermatic DDFM kostenlos online oder lade das PDF herunter. 16 Personen fanden diese Anleitung hilfreich. Frage zu diesem Modell? Stelle eine Frage

Spring Grove, Illinois 60081
www.intermatic.com
ICUBE™ Adaptive Defrost Module
Installation and Operation Manual
SAFETY SECTION
WARNING
Risk of Fire or Electrical Shock
• Disconnect the power at the circuit breaker(s) or disconnect switch(es) before
installing or servicing.
• More than one circuit breaker or disconnect switch may be required to
de-energize the equipment before servicing.
• Installation and/or wiring must be in accordance with the national and local
electrical code requirements.
• Refer to DTAV40 or DDT40 for additional warnings and installation instructions.
See www.intermatic.com if needed.
• Only use the Intermatic supplied thermistor probe kit. The probe connection(s) to
the DTAV40 and DDT40 control are NOT an isolated Class 2 circuit. Use #18-14
AWG copper conductors for the field supplied wire to the thermistor probe.
NOTICE
• Rotate the timer dial clockwise only, rotating counter-clockwise will damage the
timer.
• Do not move the clock hands on the timer. Moving the clock hands manually may
damage the timer.
• The thermistor wire may be extended up to 400 ft (122 m) using field-supplied
wiring between the DDT40 control and the thermistor probe location.
• This product is only intended to be used with Grässlin™ DTAV40 and DDT40
models.
All trademarks are the property of their respective owners.
PRODUCT DESCRIPTION
The ICUBE™ Adaptive Defrost Module, when added to an existing Grässlin™ DTAV40 - Defrost Control, provides the
DTAV40 Control with the ability to skip scheduled defrost events when they are not needed in order to save energy. Up to
four thermistor probes may be added to the control in order to monitor multiple evaporator coils. Thermistor probes may be
installed up to 400ft (122 m) away from the ICUBE™ module at a remote dedicated or multiplex condensing unit (indoor or
outdoor) or within the freezer/cooler box. No changes to the installed defrost control terminal wiring (such as the wiring for
fans, defrost heater, or thermostat) is required.
To order additional thermistor probe kits (for example, to connect multiple evaporators to one control), use part number
178GR10K-1.
ICUBE™ Adaptive Defrost Module Contents – Part Number DDFM
The kit includes:
• One 10 ft (3.05 m) thermistor probe, with clip
• One 6 ft (1.83 m) input lead
• Four wire connectors
• One dead front
• One ICUBE™ Adaptive Defrost Module, DDFM
• Four #4-40 ¼" screws
FIG. 1 ICUBE™ Module Kit Contents
Produktspezifikationen
| Marke: | Intermatic |
| Kategorie: | Schalter |
| Modell: | DDFM |
Brauchst du Hilfe?
Wenn Sie Hilfe mit Intermatic DDFM benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten
Bedienungsanleitung Schalter Intermatic
Intermatic DTAV40IM Bedienungsanleitung Intermatic P1131 Bedienungsanleitung Intermatic DT121K Bedienungsanleitung Intermatic TN111K Bedienungsanleitung Intermatic HB51K Bedienungsanleitung Intermatic DTAV40Q Bedienungsanleitung Intermatic DTAV40E2 Bedienungsanleitung Intermatic DDT40 Bedienungsanleitung
Alle Intermatic Schalter Bedienungsanleitungen
Beliebt in Schalter
Intermatic ST01 Bedienungsanleitung Intermatic DTAV40 Bedienungsanleitung Intermatic T106M Bedienungsanleitung
Bedienungsanleitung Schalter
Neueste Bedienungsanleitungen für Schalter
Huawei S220S-8T2J Bedienungsanleitung Roline 21.13.1202 Bedienungsanleitung Juniper EX4100 Bedienungsanleitung Huawei S310-48HP4X Bedienungsanleitung Roline 21.14.3523 Bedienungsanleitung Roline 21.14.3524 Bedienungsanleitung Roline 21.13.1173 Bedienungsanleitung Huawei S220-24T4X Bedienungsanleitung Huawei S310-48P4X Bedienungsanleitung Huawei S220S-24P4J Bedienungsanleitung