Ivation IVALDH70PB Bedienungsanleitung

Ivation Luftbefeuchter IVALDH70PB

Lies die bedienungsanleitung für Ivation IVALDH70PB (4 Seiten) kostenlos online; sie gehört zur Kategorie Luftbefeuchter. Dieses Handbuch wurde von 3 Personen als hilfreich bewertet und erhielt im Schnitt 4.6 Sterne aus 2 Bewertungen. Hast du eine Frage zu Ivation IVALDH70PB oder möchtest du andere Nutzer dieses Produkts befragen? Stelle eine Frage

Seite 1/4
70-Pint Energy Star
Dehumidifier
User Guide
IVALDH70PB
Thank you for purchasing the Ivation® 70-Pint Energy Star Dehumidier.
This User Guide is intended to provide you with guidelines to ensure that
operation of this product is safe and does not pose risk to the user. Any
use that does not conform to the guidelines described in this User Guide
may void the limited warranty.
for reference. This product is intended for household use only.
This product is covered by a limited one-year warranty. Coverage is
subject to limits and exclusions. See warranty for details.
Box contents
70-pint dehumidifier
User guide
Parts
1. Control panel
2. Air intake vent
3. Air lter
4. Water reservoir
5. Handle
6. Air outlet vent
7. Power cord band
8. Drain hose outlet
9. Power cord
10. Power plug
Control panel
2
5
6
7
8
9
10
1
2
3
4
11 1412 13 17
25232122 24201918
15 16
11. Filter light reset button
12. Continuous (CONT.) mode button
13. Timer button
14. Fan (TURBO) button
15. Decrease button
16. Increase button
17. Power button
18. Clean filter light
19. Continuous mode light
20. Turbo speed fan light
21. Reservoir full light
22. Auto defrost light
23. On light
24. Off light
25. Digital display
Safety precautions
Do not exceed the units rated power.
Do not pause the unit by turning off the power.
Do not use a damaged or unspecied power cord.
Do not modify the cord length or share the outlet with other appliances.
Do not handle the plug with wet hands.
Do not install the unit in a place where it may be exposed to
combustible gas.
Do not place the unit near a heat source.
Disconnect the power if unusual sounds, smells, or smoke, comes from
the unit.
Never attempt to take apart or repair the unit.
Before cleaning the unit, always turn off the power and unplug.
Do not drink or use the water drained from the unit.
Do not remove the water reservoir during operation.
Do not place the unit in a place where it may become wet or damp.
Always place the unit on a level, stable section of the oor.
Do not cover the intake or exhaust vents with cloths or towels.
Keep out of reach of children or pets.
Do not use in areas where chemicals are handled.
Never insert fingers or other foreign objects into the vents or openings.
Do not place heavy objects on the power cord.
Do not climb on or sit on the unit.
Always insert the filters securely. Clean the lter once every two weeks.
If water enters the unit, turn it off and disconnect the power. Contact a
qualified service technician.
Operation
Before turning the unit on, position it as
seen in the diagram. Be sure that you
place the unit in a room that is between
41°F (5°C) and 95°F (35°C).
Automatic features
AUTO SHUT OFF: The unit will
automatically shut off when
either the reservoir is full or
the set humidity is reached.
Wait 3 minutes before
resuming operation.
AUTO DEFROST: When frost builds up on the evaporator coils, the
compressor will cycle off and the fan will continue to run until the unit
has defrosted.
AUTO RESTART: If the power is cut unexpectedly, the unit will restart
with the previous settings when power resumes.
Manual features
COMFORT MODE: This mode will set the unit to automatically control
humidity between 45%-55% based on the temperature of the room. Note
that the humidity cannot be manually set while in this mode.
FILTER: When it is time to clean thelter, the clean filter light will turn on.
To reset the light after cleaning thelter, press the lter light reset button.
CONTINUOUS MODE: To set the dehumidifier to run constantly without a timer,
press the continuous mode button. The continuous mode light will turn on.
HUMIDITY CONTROL: Relative humidity can be adjusted in 5% increments. For
dryer air, press the minus button. For damper air, press the plus button. Note
that relative humidity can be set within a range of 35% to 85%.
TIMER: The timer can be set to indicate either when the dehumidifier will start
or when it will stop. To set a time, press the timer button until the desired timer
light turns on. Use the increase and decrease buttons to adjust the time in .5
hour increments up to 10 hours.
FAN: Press the fan button to switch between high and low fan speed. Note that
the higher fan speed will remove more moisture.
Removing collected water
Collected water can be removed in the following ways:
1. When the water reservoir is full, remove and empty it.
2. Continuous draining: water can be automatically emptied
into a oor drain by attaching the unit to a water hose
with a female threaded end (not included).
a. Remove the plastic cover from the drain
outlet of the unit and set aside.
b. Remove the water reservoir and insert
the hose through the drain outlet of the
unit, pressing it securely into the connector
on the front of the unit.
c. Tighten the adapter and the unit with two
screws (not included).
3
more than 40cm
more than 20cm
more than 20cm
more than 20cm
Drain hose
subassembly
Connector
Drain hose
Plastic cover


Produktspezifikationen

Marke: Ivation
Kategorie: Luftbefeuchter
Modell: IVALDH70PB

Brauchst du Hilfe?

Wenn Sie Hilfe mit Ivation IVALDH70PB benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten