Lies die bedienungsanleitung für Kidde CV2208 (3 Seiten) kostenlos online; sie gehört zur Kategorie Nicht kategorisiert. Dieses Handbuch wurde von 2 Personen als hilfreich bewertet und erhielt im Schnitt 4.0 Sterne aus 1.5 Bewertungen. Hast du eine Frage zu Kidde CV2208 oder möchtest du andere Nutzer dieses Produkts befragen? Stelle eine Frage

Seite 1/3
RF connection is done with the device powered
with battery only. You do not have to connect the
power supply. The product label must not be re-
moved as it contains important information re-
garding the product.
All alarms to be connected in the house should
be put into Learn Mode by sliding the switch on
the back of the alarm to the Learn Mode position.
Please note: The learn switch placed on the back
of the alarm can only be in learn position when
the alarm is disassembled from the power supply
unit. The learn switch will automatically switch to
the power supply.
The red LED will light up to indicate that Learn
Mode has been selected.
until it beeps and the LED ashes. This alarm will
become the master and will start sending out a
specic house code to the other alarms.
As the other alarms receive the specic house
code, they will also ash the LED light.
When the red LED light flashes on all alarms,
they are connected and MUST BE SWITCHED
OUT OF LEARN MODEand installed.
Label the original Learn alarm in order to easily
add new CAVIUS Wireless Family alarms to the
system.
2. THE BEST AREAS TO INSTALL THE SMOKE
ALARM:
Note the local country regulations regarding
installation.
Note the local regulations about information
to your insurance company regarding installed
smoke alarms.
• Install an alarm between possible re sources
and bedrooms as a minimum.
• Install alarms on each oor of the house, in
hallways and landings.
Alarms in each room such as bedrooms and
living rooms.
Additional alarms increase the security.
3. NOTAREAS WHERE TO INSTALL SMOKE
ALARMS:
In dusty rooms
At the top of a high pointed ceiling, in ceiling
corners, and within 50cm of a wall.
In rooms where temperature goes outside the
range +4
o
to 3Cor above 90% relative humidity
not condensing.
In kitchens, garages, laundries, or too close to
replaces; areas where either dampness, gases
or smoke could occur.
Place the alarm where it is reachable in order to
test the alarm and for maintenance.
4. PLACEMENT:
ceiling. With a minimum of one smoke alarm per
alarms of 10 meters.
For ceiling installation:
The smoke alarm should be a minimum of 30cm from
the wall.
Mains powered smoke alarm device
Model no.: 2208
The smoke alarm is designed for private homes.
PLEASE READ THE INSTALLATION GUIDE
CAREFULLY BEFORE INSTALLATION AND
RETAIN FOR FUTURE USE.
SAFETY INSTRUCTIONS:
The device comes with a 3V lithium battery. Bat-
teries are to be handled with care and battery pow-
ered devices should be kept out of reach of chil-
dren. Do not try to recharge or burn the batteries.
TECHNICAL INFORMATION:
Powered by a non-replaceable 3V CR123 Lith-ium
battery with 10-year life (included).
It can be RF interlinked with other CAVIUS
Wireless Family alarms.
The maximum number of alarms that can be
interlinked within a house group are 32. Please
note: These must be alarms from the CAVIUS Wire-
less Alarm Family.
The distance between interlinked alarms depends
on the house layout and they should always be
tested after installation. It is not advised to install
alarms with a separation of more than 10m.
Diameter: 97mm. Height: 41mm (without mount-
ing base) 52mm (with mounting base).
1. HOW TO SET UP AND CONNECT ALARMS:
Start by pulling out the battery isolation strip as
shown.
UK
1
Minimum 30cm
from wall
Wall
Ceiling
CHAMBER
FILTER
TEST BUTTON
SOUND
OUTPUT
RED & GREEN LED
Optical
Siting of Optical Smoke alarms
ISOLATION
STRIP
NORMAL MODE
2
LEARN MODE
1
2
1
Connect the 3 wires to the power supply: Live
feed (L1), neutral (N), earth ( ).
Screw the mounting base on the ceiling.
Screw the power supply on the mounting base.
Once the mounting base with power supply is
installed, attach the alarm by twisting clockwise
until it clicks.
OPTION 2: ALARM MOUNTED ON TOP OF
CONDUIT BOX:
alarm power supply:
Live feed (L1), neutral (N), earth ( ).
Screw the power supply on conduit box.
NOTE: Mounting base is not used when
the alarm is installed on conduit box.
6. SAFETY LOCK:
7. TEST FUNCTION:
After installation, and at least once per quarter,
test all of your alarms to ensure they are operating
correctly and are within range of each other.
It is recommended to check visually every week if
the LED ashes correctly (every 48sec.).
10 seconds.This will send out a test signal
from the alarm; all other connected alarms
should receive the signal within a short time.
The alarms will emit a short beep and the LED
will ash every 8 seconds for 2 minutes.
NOTE: Test function also transmits a weaker RF
signal to ensure an optimal operation in normal
conditions.
When the test signal is sent out, the alarms will
respond in two ways:
1. A single beep every 8 seconds indicates that
the alarms are connected and functioning.
by running the vacuum (on a low setting) around
the smoke alarm chamber and tested again.
For cathedral or peak ceiling:
5. INSTALLING THE SMOKE ALARM:
NOTE: THIS ALARM NEEDS TO BE INSTALLED
BY A PROFESSIONAL.
MAKE SURE ELECTRICITY IS SWITCHED OFF
BEFORE STARTING THE INSTALLATION.
CAUTION: LIVE, NEUTRAL AND EARTH MUST
BE CORRECTLY INSTALLED AND NOT MIXED UP.
NOTE: The alarm is delivered in the packaging
with a dust cover, installed to protect the alarm for
exposure to excessive dust which could potentially
damage or reduce the function of the alarm while
the building is under construction. The dust cover
must be removed after the building is fully cleaned.
OPTION 1: ALARM MOUNTED ON MOUNTING
BASE OUT ON THE CEILING:
Use the mounting base ring to mark the screw
holes on the ceiling.
For surface wiring pass the feed wire through
the mounting base cable holder and screw after
termination.
2
MARK UP
4 SCREW HOLES
WITH A PEN
L1
L2
N
L2
N
L1
USE THE
ENCLOSED
SCREWS AND
PLUGS
Peak ceiling
Minimum 60cm
from peak
Mount the
safety lock
WARNING: This is a mains powered unit
and can be hazardous to install. We recommend
that the installation, together with any associated
sup-ply and interconnecting wiring, is only to be
done by a professional in accordance with BS
7671:2018.
Hereby, Cavius declares that the radio equipment
type 2208 is in compliance with Directive 2014/53/
EU.
The full text of the EU declaration of conformity is
available at the following internet address: www.
cavius.com
Carrier assumes no responsibility for any errors,
which may appear in this manual. Furthermore,
Carrier reserves the right to alter the hardware,
at any time without notice, and Carrier does not
make any commitment to update the infor mation
contained herein.
Manufacturer: Carrier Fire & Security Danmark A/S,
Ellekær 9A, 2. Th, DK-2730. Made in China.
If required this indication can be stopped early on
each alarm by a short press of the test button.
TIP: It is safe to cover the sound output holes with
the sound level emitted.
If the problem continues, please visit www.cavius.com
for any trouble shooting.
8. ADD EXTRA DEVICE:
The mains powered smoke alarm can be used
together with the alarms in the CAVIUS wireless
family: Smoke, Heat & mains power alarms. All
CAVIUS interconnected alarms within the
as they run on same frequency and use the same
data protocol.This means that the wireless sys-
tem can consist of a combination of smoke, heat
etc.
can be added to the system
3
400144 rev7
HEAT ALARM
SM ALARMOKE
M N REDAI S POWE
SM ALARMOKE
M N REDAI S POWE
HEAT ALARM
Place all alarms into Learn Mode and repeat
section 1.
test function section 7 after adding devices.
9. OTHER INFORMATION:
Do not paint the alarm.
Disposal: Please dispose properly at the end of
life. This is electronic waste which should be re-
cycled.
Complies to the Radio Equipment Directive
2014/53/EU
RF frequency: 868 MHz.
Maximum radio-frequency power transmitted: 20
dBm
Full DoC to 2014/53/EU (RED) can be download-
ed at www.cavius.com
WARNING: Please remove dust cover after
installation. Smoke will not be able to reach the
chamber while dust cover is in place.
WARNING: All alarms should be assumed as due
to actual re and the dwelling should be evacuat-
ed immediately.
be permanently xed to the ceiling/wall in accor-
dance with the installation instructions.
WARNING: Batteries shall not be exposed to ex-
cessive heat such as shine, re, or the like. Note
the local country regulations regarding installa-
tion.
The CE and RED declaration of conformity and DoP can be downloaded from: http//www.cavius.com
The paper version of the DoP is available free of charge upon request.
2
3
DoP no.: 102.0022
2797
2
3
0086
DoP no.: 103.0012
EN 14604:2005 + AC:2008


Produktspezifikationen

Marke: Kidde
Kategorie: Nicht kategorisiert
Modell: CV2208

Brauchst du Hilfe?

Wenn Sie Hilfe mit Kidde CV2208 benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten