Lies die bedienungsanleitung für Klein Tools ET250 (13 Seiten) kostenlos online; sie gehört zur Kategorie Messung. Dieses Handbuch wurde von 2 Personen als hilfreich bewertet und erhielt im Schnitt 4.8 Sterne aus 1.5 Bewertungen. Hast du eine Frage zu Klein Tools ET250 oder möchtest du andere Nutzer dieses Produkts befragen? Stelle eine Frage

Seite 1/13
INSTRUCTION MANUAL
600V
FRANÇAIS pg. 17
ESPAÑOL pg. 9
Digital AC/DC Voltage &
Continuity Tester
AUTOMATICALLY
SELECTS
MEASUREMENT
MODE
MODERN
SOLID-STATE
DESIGN
TEST GFCI
PROTECTED
CIRCUITS
INTEGRATED
WORKLIGHT
BUILT-IN
TEST LEAD
HOLDERS
BACKLIT
LCD DISPLAY
ENGLISH
ET250
3m IP53
5001748
CAT IV
600V
2 3
GENERAL SPECIFICATIONS
Klein Tools ET250 is a solid-state, digital voltage and continuity
tester. It measures AC/DC voltages up to 600V and tests for
continuity. Additionally, the ET250 tests GFCI protected circuits to
verify that the GFCI device is functioning appropriately. The tester
includes a backlight and worklight for working in reduced ambient
lighting conditions.
Operating Altitude: ≤ 6562 ft. (2000 m)
Relative Humidity: <80% non-condensing
Operating Temperature: 5°F to 113°F (-15°C to 45°C)
Storage Temperature: -4°F to 140°F (-20°C to 60°C)
Battery Type: 3 x 1.5V AAA
Dimensions: 6.06" x 2.33" x 1.64" (153.8 x 59.2 x 41.6 mm)
Weight: 6 oz (170 g) without test leads
Calibration: Accurate for one year
Standards:
Conforms to EN61326-1:2013, EN61326-2:2013,
UL STD. 61010-1, 61010-2-030 and
61010-2-033.
Certified to CSA STD. C22.2 NO. 61010-1,
61010-2-030 and 61010-2-033
Pollution degree: 2
Drop Protection: 9.8 ft. (3m)
Ingress Protection:
IP53 (see WARNINGS)
Safety Rating: CAT IV 600V, Class 2, Double insulation
CAT IV: Measurement category IV is applicable to test and
measuring circuits connected at the source of the building’s
low-voltage MAINS installation.
Electromagnetic Environment: IEC
EN61326-1:2013
. This
equipment meets requirements for use in basic and controlled
electromagnetic environments like residential properties,
business premises, and light-industrial locations.
Specifications subject to change.
ENGLISH
ELECTRICAL SPECIFICATIONS
AC Voltage Range: 2 – 600V AC RMS (45 – 400Hz)
DC Voltage Range: 2 – 600V DC
Maximum Measurable Voltage:
600V RMS
Resolution: 1V
Accuracy: ±(2% + 2V)
Test Current:
< 0.3mA at 120V AC RMS or 120V DC
Continuity: 0 – 270kΩ
GFCI Test:
>6mA via button
Nominal Voltage GFCI Testing: 10-135V AC at 50/60Hz in
3-wire outlet
Auto-Detect: Tester auto-detects and selects VAC / VDC /
Continuity modes
Specifications subject to change.
WARNINGS
To ensure safe operation and service of the tester, follow these
instructions. Failure to observe these warnings can result in
severe injury or death.
Before each use verify tester operation by measuring a known voltage.
Never use the tester on a circuit with voltages that exceed the
category based rating of this tester.
Do not use the tester during electrical storms or in wet weather.
Do not use the tester or test leads if they appear to be damaged.
Replacement test-leads should conform to EN 61010-031 and
be rated CAT IV 600V, 10A, or better. Do not use lower rated
test leads.
Ensure tester leads are fully seated, and keep fingers behind
the finger guards and away from the metal probe contacts
when making measurements.
Use caution when working with voltages above 25V AC RMS
or 60V DC. Such voltages pose a shock hazard.
To avoid false readings that could lead to electric shock,
replace batteries when a low battery indicator appears.
Always adhere to local and national safety codes. Use personal
protective equipment to prevent shock and arc blast injury
where hazardous live conductors are exposed.
Tester is IP53 dust & water resistant. Following any contact
with water, thoroughly dry tester and test lead jacks prior to
subsequent use.