Lies die bedienungsanleitung für Lowell ACS-2006-3C-RPCP-HW (3 Seiten) kostenlos online; sie gehört zur Kategorie Nicht kategorisiert. Dieses Handbuch wurde von 2 Personen als hilfreich bewertet und erhielt im Schnitt 4.4 Sterne aus 1.5 Bewertungen. Hast du eine Frage zu Lowell ACS-2006-3C-RPCP-HW oder möchtest du andere Nutzer dieses Produkts befragen? Stelle eine Frage
Seite 1/3

Lowell strives to provide accurate information while reserving the right to change specications and/or improve manufacturing methods without prior notication.
©2021 Lowell Manufacturing Co., 100 Integram Dr., Pacic MO 63069 / tel. 800.325.9660 / www.lowellmfg.com
Spec 2319
Model ACS-2006-3C-RPCP-HW Rev. 12-08-21 | pg. 1/3
INTERNAL USE ONLY: PN 24552
This hardwired power strip features three circuits featuring a total of (3) 20A duplex outlets.
One circuit with a duplex outlet is unswitched (always on). The other two circuits (one duplex
each) are activated by a compatible sequencer (model SEQ-P4 or SEQR-P4) which is required
for activation (order separately).
FEATURES:
• Outlets: Total of three (3) NEMA 5-20R duplex outlets
• Power Rating: 120VAC 60Hz 20A each circuit
• Unswitched Circuits: One unswitched circuit is always on (1 duplex).
• Switched Circuits: Two switched circuits (1 duplex each) are controlled by an external
sequencer. Each circuit has its own DIP switch to set its position in the sequencing order (1,
2, 3, or 4). Set one (and only one) step for each circuit.
Note: Two or more circuits can be assigned to the same sequencing step. However, each
circuit must only be assigned a single step (because it can only activate once). If any circuit is
not assigned a step, that circuit will not activate. If any circuit is assigned more than one step,
the entire system will malfunction.
• Pass-through RJ45 Jacks:
– The switched circuits are internally connected to the RJ45 jacks and will therefore be
controlled by the external sequencer when it's connected to either jack (using Cat5/6 cable,
not included).
– The RJ45 jacks can be used to daisy chain compatible remote power controls or relays (up
to 20 devices per step). See RPC-P or RY-P Series on last page.
• Surge Protection: Each of the two switched circuits includes surge protection — the
unswitched circuit is not protected.
– Maximum Surge Current: 10,000A
– VPR: 400V
– Response Time: 1 nanosecond
– EMI/RFI Noise Reduction: 20dB@100kHz
– Protection Mode: Line to Neutral
– Ground Contamination: None
• Chassis: 30" x 2" x 2" steel chassis with black powder epoxy finish.
• Non-metallic Flexible Conduit: Terminates to six ft. flexible conduit with pigtail leads tagged
for circuit identification. Conduit can be trimmed in the field as needed.
• Mounting Brackets: Universal mounting brackets provide versatility allowing the outlets to
face forward, center or rear of rack. Minimal rack panel space required = 33.25" (19U).
• Origin: Made in the U.S.A. with global components.
• Third Party Listing: ETL Listed (to UL 60065)
• A&E Specifications: The hardwired power strip shall be Lowell model ACS-2006-3C-RPCP-HW
with power rating of 120VAC 60Hz 20A. The 30" x 2" x 2" steel chassis with black powder epoxy
finish shall include three circuits and three NEMA 5-20R duplex outlets. One duplex outlet shall
be on an unswitched circuit (always on). The other duplex outlets shall be on two switched circuits
which shall be activated and deactivated by Lowell power sequencer model SEQ-P4 or SEQR-P4
(ordered separately). The power strip shall feature surge protection up to 10,000A on the two
switched circuits; the unswitched circuit shall not have protection. The unit shall include universal
mounting brackets and a six ft. non-metallic flexible conduit with pigtail leads. The power strip shall
be made in the USA with global components. It shall be ETL Listed.
3-circuit power strip with pass-thru jacks: ACS-2006-3C-RPCP-HW
Unswitched
Circuit:
(always on)
Rotating connector
for 6 ft. exible
conduit
Pass-through
RJ45 jacks –
in from a sequencer
(out to compatible
devices, if desired)
Switched
Circuit 1:
Switched
Circuit 2:
LED status
indicator and
sequence step
switch
LED status
indicator and
sequence step
switch
Mounting brackets
Made in USA

Lowell strives to provide accurate information while reserving the right to change specications and/or improve manufacturing methods without prior notication.
©2021 Lowell Manufacturing Co., 100 Integram Dr., Pacic MO 63069 / tel. 800.325.9660 / www.lowellmfg.com
Spec 2319
Model ACS-2006-3C-RPCP-HW Rev. 12-08-21 | pg. 2/3
INTERNAL USE ONLY: PN 24552
Unswitched
Circuit
(always on)
Circuit 1
(switched)
Circuit 2
(switched)
Parallel connect to sequencer SEQ-P4 or SEQR-P4 (required for activation)
and compatible remote power controls or relays (RPC-P or RY-P series), if desired.
Standard CAT5/6 cables w/RJ45
connectors. Max. distance to
farthest unit = 5,000 ft.
To/from SEQ-P4, SEQR-P4,
RPC-P series or RY-P series
Circuit 1
GREEN – Ground
Circuit 2
Unswitched duplex outlet
(not tagged)
BLACK – Line (Hot)
WHITE – Neutral
(all circuits)
6 ft. non-metallic exible conduit
with rotating connector
Each circuit must be assigned to ONLY ONE sequence step (1, 2, 3 or 4).
If more than one step is assigned to a circuit, the entire system will malfunction.
If no step is assigned, the circuit will not turn on.
Surge
Protect
Power
Activated
Assign to a Single
Sequence Step
Test
Norm
1 2 4 3
To/from SEQ-P4, SEQR-P4,
RPC-P series or RY-P series

Lowell strives to provide accurate information while reserving the right to change specications and/or improve manufacturing methods without prior notication.
©2021 Lowell Manufacturing Co., 100 Integram Dr., Pacic MO 63069 / tel. 800.325.9660 / www.lowellmfg.com
Spec 2319
Model ACS-2006-3C-RPCP-HW Rev. 12-08-21 | pg. 3/3
INTERNAL USE ONLY: PN 24552
UNIVERSAL BRACKETS:
Brackets include multiple hardware sets for versatile installation:
(2) Brackets
(2) 1/4"-20 x 1/2" screws
(2) Flat nuts
(2) 10-32 x 1/2" screws
(2) Cage nuts
COMPATIBLE PASS-THROUGH DEVICES:
Order separately.
This
spec
Model No.
Description Power Rating Power Input Connection Output Connection Surge Supp.Output Voltage Rating Activation Trigger
SEQ-P4
Sequencer Power supply
External switch or DSP conn*
SEQR-P4
Sequencer, rackmount Power supply Built-in sw, external sw or DSP*
RPC-P15
Remote Power Control 125VAC 15A 5-15P cord 5-15R duplex SEQ-P4 or SEQR-P4**
RPC-P15-U
Remote Power Control 100-240VAC 15A C14 cord C13 duplex SEQ-P4 or SEQR-P4**
RPC-P15-S
Remote Power Control 125VAC 15A 5-15P cord 5-15R duplex
✓
SEQ-P4 or SEQR-P4**
RPC-P20-SCD
Remote Power Control 125VAC 20A 5-20P cord 5-20R duplex
✓
SEQ-P4 or SEQR-P4**
RPC-P20-SHW
Remote Power Control 125VAC 20A Flexible whip 5-20R duplex
✓
SEQ-P4 or SEQR-P4**
RPC-P30-SHW
Remote Power Control 125VAC 30A Flexible whip L5-30R twistlock
✓
SEQ-P4 or SEQR-P4**
RY-P1
Relay (1 DPDT) Power supply DPDT Relay 5A SEQ-P4 or SEQR-P4**
RY-P2
Relay (2 DPDT) Power supply DPDT Relay 5A SEQ-P4 or SEQR-P4**
ACS-2006-3C-RPCP-HW
Power Strip w/remote 120VAC 20A Felxible whip 5-20R duplex (3)
✓
***
SEQ-P4 or SEQR-P4**
ACS-2018-5C-RPCP-HW
Power Strip w/remote 120VAC 20A Flexible whip 5-20R duplex (9)
✓
***
SEQ-P4 or SEQR-P4**
* Order activation trigger separately, as needed.
** Note that only the first remote device in a string requires connection to the sequencer for activation. A second device would connect to the first using the pass-through
RJ45 jacks. Additional devices can be connected to each other in a similar way (up to 20 devices per step).
*** Each of the two switched circuits contains surge protection (the unswitched circuit does not).
All pass-through devices require sequencer SEQ-P4 or SEQR-P4 for activation. Optional add-on compatible devices are also listed in the chart below. See
individual product spec sheets for more information.
3) REATTACH CONNECTOR:
Twist/push the connector to attach it
to the shortened conduit.
1) REMOVE EXCESS LENGTH:
Snip reinforcing rib at desired length.
Bend the conduit to expose the cut
and carefully cut around the conduit
without cutting the wires inside.
Remove excess length.
2) REMOVE CONNECTOR:
Carefully snip the last rib(s) to loosen
the connector from the excess length,
then twist/pull to remove it.
HOW TO TRIM THE CONDUIT: The 6 ft. non-metallic exible conduit can be trimmed in the eld.
Produktspezifikationen
Marke: | Lowell |
Kategorie: | Nicht kategorisiert |
Modell: | ACS-2006-3C-RPCP-HW |
Brauchst du Hilfe?
Wenn Sie Hilfe mit Lowell ACS-2006-3C-RPCP-HW benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten
Bedienungsanleitung Nicht kategorisiert Lowell
19 Juni 2025
19 Juni 2025
19 Juni 2025
19 Juni 2025
19 Juni 2025
19 Juni 2025
18 Juni 2025
18 Juni 2025
18 Juni 2025
18 Juni 2025
Bedienungsanleitung Nicht kategorisiert
- SPC
- Lexicon
- Baby Annabell
- Atmotube
- Perma
- GW Instek
- Eta
- Boso
- Saint Algue
- Idec
- Dacor
- Hisense
- Solac
- JAR Systems
- Swissonic
Neueste Bedienungsanleitung für -Kategorien-
19 Juni 2025
19 Juni 2025
19 Juni 2025
19 Juni 2025
19 Juni 2025
19 Juni 2025
19 Juni 2025
19 Juni 2025
19 Juni 2025
19 Juni 2025