Manitowoc IYT0620A Bedienungsanleitung


Lesen Sie kostenlos die 📖 deutsche Bedienungsanleitung für Manitowoc IYT0620A (6 Seiten) in der Kategorie Eismaschine. Dieser Bedienungsanleitung war für 2 Personen hilfreich und wurde von 1.5 Benutzern mit durchschnittlich 4.7 Sternen bewertet

Seite 1/6
Restoring Ice Machine
to Service
Subject: Indigo NXT Ice Machines
AIR-COOLED, WATER-COOLED, REMOTE AIR-COOLED &
QUIETQUBE ICE MACHINES
1 of 6
Document Number: MSC-017 4/20
MANITOWOC ICE MACHINE DIVISION
2110 SOUTH 26TH STREET, MANITOWOC, WI 54220
844-724-CARE
RESTORING TO SERVICE PROCEDURES
1. Remove front panel.
Use a Phillips screwdriver to
loosen the screw(s) securing
the door. Do not remove
screw(s) completely; they
are secured to prevent loss.
2. Make sure ice machine
off.
Turn the ice machine OFF
by pressing the power
button.
3. Disconnect main
power at the service
disconnect or breaker.
n
WARNING
Do not begin cleaning
other parts of the ice
machine until line voltage is
disconnected from the ice
machine and if applicable
dispenser.
4. Empty ice bin, if not
already empty.
Use an ice scoop to remove
all ice from the storage bin
or dispenser.
5. Remove top cover and
evaporator dust cover
(when used).
Lift top cover to remove,
then lift and remove
evaporator dust cover.
6. Remove water curtain
or splash shield.
Remove water curtain
Gently flex the curtain in the
center and remove it from
the right side.
Slide the left pin out.
Manitowoc recommends a Factory Authorized Service company or Distributor Authorized Service Dealer perform
thorough preventative maintenance prior to restoring service of the Manitowoc ice machine, storage bin or
dispenser. Section 4 (Maintenance) of the Installation, Operation and Maintenance manual should be followed to
ensure proper cleaning and sanitizing steps are completed.
Water system components including the water inlet valve, water pump and dump valve may require removal for
inspection or replacement depending on the potable water quality and the length of time the components had no
use. Water cooled ice machines may require the condenser be cleaned and the refrigeration water regulating valve
evaluated for proper performance. Air-cooled condensers should be cleaned. This is also a good time to replace
water filtration, replenish AuCS chemical and replace the Luminice bulb if these Manitowoc accessories are used.
2 of 6
Document Number: MSC-017 4/20
Subject: Restoring Ice Machine to Service Procedures
Remove splash shield
48” models.
Lift the splash shield up and
forward to remove.
Remove splash shields (2)
Dual Evaporator Models.
Grasp the top center of
splash shields. Lift up and
then out.
7. Remove water trough
Depress tabs on right and
left side of the water trough.
Allow front of water trough
to drop as you pull forward
to disengage the rear pins.
Refer to Step 12 for Dual
Evaporator Trough Removal.
8. Remove the water
level probe.
Pull the water level probe
straight down to disengage.
Lower the water level probe
to obtain access. The water
level probe can be descaled
and sanitized at this point
without complete removal.
If complete removal is
desired, disconnect the ice
thickness control wire from
the control board.
NOTE: Some models allow
disconnection of the wire
lead from the water level
probe. Lower the water
level probe until the wiring
connector is visible, then
disconnect the wire lead
connector from the water
level probe and remove
from the ice machine.
Refer to Step 11 for Dual
Evaporator Water Pump and
Water Level Probe Assembly
Removal.
9. Remove the water
pump.
Grasp pump and pull
straight down on pump
assembly until disengaged
and the electrical connector
is visible. Disconnect
the electrical connector.
Remove the water pump
assembly from ice machine.
Refer to Step 11 for Dual
Evaporator Water Pump and
Water Level Probe Assembly
Removal.
3 of 6
Document Number: MSC-017 4/20
Subject: Restoring Ice Machine to Service Procedures
Remove Ice damper(s)
when used. (Dual
Evaporators have two).
Disengage the front and rear
pins of the left damper and
right damper.
10. DUAL EVAPORATORS
ONLY: Remove the
water trough shield.
Grasp the water trough
shield in the center and the
left end.
Flex the water trough shield
in the center and pull the
left end forward until clear
of the side wall. Repeat for
the right end.
Pull water trough shield
forward to remove.
11. Remove the water
pump and water level
probe assembly.
The water pump and water
level probe are removed
from the front right side
of the machine. Pull up on
the water pump and water
level probe assembly to
disengage.
The water pump and water
level probe can be descaled
and sanitized at this point
without complete removal.
If complete removal is
desired, disconnect at the
molex connectors.
12. Remove water trough.
Once the water pump
and water level probe are
removed (step 11); slide the
water trough forward-out of
the ice machine.
13. Remove the ice
thickness probe(s)
(Dual Evaporator have
two).
Compress the hinge pin on
the top of the ice thickness
probe.
Pivot the ice thickness probe
to disengage one pin then
the other.
The ice thickness probe
can be cleaned at this point
without complete removal.
If complete removal is
desired, disconnect the ice
thickness control wiring
from the control board.
14. Remove the water
distribution tube(s)
(Dual Evaporator have
two).
Loosen the two outer
screws (do not remove
screws completely; they
are retained to prevent
loss). Pull forward on the
distribution tube to release
from slip joint. Remove the
water distribution tube.
Disassemble the distribution
tube by loosening the two
(2) middle thumbscrews and
dividing the distribution
tube into two pieces.
Remove both water
distribution tubes on 48”
and dual evaporator models.