Lies die bedienungsanleitung für Mean Well EPP-400-18 (2 Seiten) kostenlos online; sie gehört zur Kategorie Nicht kategorisiert. Dieses Handbuch wurde von 146 Personen als hilfreich bewertet und erhielt im Schnitt 4.8 Sterne aus 2 Bewertungen. Hast du eine Frage zu Mean Well EPP-400-18 oder möchtest du andere Nutzer dieses Produkts befragen? Stelle eine Frage
Seite 1/2

Installaon Manual
Type:
:
:
::Open Frame (PCB) Type Switching Power Supply
(Families: PM, NFM, IRM, MPS, MPD, MPT, MPQ, RPS, RPD, RPT, PS, PD, PT, PQ, PPS, PPT, PPQ, ASP, PID,
LPS, LPP, EPS, ELP, EPP)
Introducon
An open frame (PCB) type switching power supply is a power supply designed to be integrated or installed into a
system enclosure. Mean Well’s open frame (PCB) type power supplies include on board, general PCB, green PCB,
and medical PCB types .
Installaon
( )1Before commencing any installation or maintenance work, please disconnect your system from the
ulity. Ensure that it cannot be re-connected inadvertently!
( )2At least 5mm insulaon distance on the boom of the unit should be kept and a Mylar lm should be
added between the unit and the system. In addion, enough insulation distance, for keep10mm
general type/15mm for medical type, around the unit.
( )3Power supplies greater than 120W may require a forced air/fan for cooling. Please refer to
specicaons to receive a minimum air intensity and air-ow direcon.
( )4Allow good venlaon for the unit in use to prevent it from overheang. Also, a 10-15 cm clearance
must be kept when the adjacent device is a heat source.
( )5Mounng orientaons other than standard orientaon or operate under high ambient temperature
may increase the internal component temperature and will require a de-rang in output current.
Please refer to the specicaon sheets to receive the opmum mounng posion and informaon
about the -rang curve.de
( )6Recommended wires are shown as below.
AWG
18
16
14
12
10
8
Rated Current of
Equipment (Amp)
6A
6-10A
10- 16A
1625A-
2532A-
3240A-
Cross-secon of
Lead(mm2 )
0.75
1.00
1.5
2.5
4
6
Note:Current each wire carries should be de-rated to 80% of the current
suggested above when using 5 or more wires connected to the unit.
( )7For other informaon about the products, please refer to www.meanwell.com for details.
Warning / Cauon !!
( )1Risk of electrical shock and energy hazard. All should be examined by a qualied technicianfailure .
Please do not try to x the power supply by yourself!
( )2Please do not install power supplies in places with high moisture or near the water.
( )3Please do not install power supplies in places with high ambient temperature or near re source.
Please refer to the specicaons about the maximum ambient temperature limitaons.
( )4Output current and output waage must not exceed the rated values on specicaons.
( )5The ground (FG) must be connected to earth ground.
( )6All MW’s PSUs are designed in accordance with EMC regulaons and the related test reports are
available by request. Since they are belong to component power supplies and will be installed inside
system enclosure, when they are integrated into a system, the EMC characteriscs of the end
system must be re-veried again.
Produktspezifikationen
| Marke: | Mean Well |
| Kategorie: | Nicht kategorisiert |
| Modell: | EPP-400-18 |
| Breite: | 76.2 mm |
| Tiefe: | 127 mm |
| Gewicht: | 390 g |
| Höhe: | 35 mm |
| Menge pro Packung: | 36 Stück(e) |
| Ausgangsspannung: | 18 V |
| Ausgangsleistung: | 400 W |
| Eingangsspannung: | 80 - 264 V |
| Nachhaltigkeitszertifikate: | RoHS |
Brauchst du Hilfe?
Wenn Sie Hilfe mit Mean Well EPP-400-18 benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten
Bedienungsanleitung Nicht kategorisiert Mean Well
8 September 2025
8 September 2025
8 September 2025
8 September 2025
7 September 2025
6 September 2025
6 September 2025
6 September 2025
6 September 2025
6 September 2025
Bedienungsanleitung Nicht kategorisiert
Neueste Bedienungsanleitung für -Kategorien-
1 Februar 2026
1 Februar 2026
1 Februar 2026
1 Februar 2026
1 Februar 2026
1 Februar 2026
1 Februar 2026
1 Februar 2026
1 Februar 2026
1 Februar 2026