SAFETY
WARNINGS
•Safety Warningsand Precautionsmust be read and
understood before the instrument is used. They
mustbe
observed during use.
•The circuit under test mustbe de-energised and isolated
before connections are made except for voltage
measurement.
•Circuit connections must notbe touched during a test.
•After insulation tests, capacitive circuits must be allowed to
discharge
before disconnecting the test leads.
•The Live Circuit Warning and Automatic Discharge are
additional safety features and
should notbe regarded as a
substitute for normal safe working practice.
•Replacement fuses must be of the correct type and rating.
Failure to fit the correctly rated fuse
will result in damage to
the instrument in the event of an overload.
•Test leads, including crocodile clips, must be in good order,
clean and have no broken or cracked insulation.
•Ensure that hands remain behind guards of probes/clips when
testing.
•U.K. Safety Authorities recommend the use of fused test leads
when measuring voltage on high energy systems.
NOTE
THE INSTRUMENTS MUST ONLY BE USED BY
SUITABLY TRAINED AND COMPETENT PERSONS
Users of this equipment and/or their employers are reminded that
Health and Safety Legislation require them to carry out valid risk
assessments of all electrical work so as to identify potential
sources of electrical danger and risk of electrical injury such as
from inadvertent short circuits. Where the assessments show that
the risk is significant then the use of fused test leads constructed
in accordance with the HSE guidance note GS38 ‘Electrical Test
Equipment for use by Electricians’ should be used.
Symbols used on the instruments are:
Caution, risk of electric shock.
Caution, refer to User Guide.
Equipment protected throughout by
Double Insulation (Class II).
Equipment complies with current EU Directives.
Equipment must not be connected to
installations >500V.
>500V
Produktspezifikationen
| Marke: | Megger |
| Kategorie: | Multimeter |
| Modell: | BMM2000 |
Brauchst du Hilfe?
Wenn Sie Hilfe mit Megger BMM2000 benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten
Bedienungsanleitung Multimeter Megger
Megger AVO830 Bedienungsanleitung Megger FCC3450 Bedienungsanleitung Megger AVO 415 Bedienungsanleitung Megger KC-C Bedienungsanleitung Megger DCM320 Bedienungsanleitung Megger BMM80 Bedienungsanleitung Megger MET1000 Bedienungsanleitung Megger BMM2500 Bedienungsanleitung
Alle Megger Multimeter Bedienungsanleitungen
Beliebt in Multimeter
Megger AVO835 Bedienungsanleitung Megger AVO210 Bedienungsanleitung Megger DPM1000 Bedienungsanleitung
Bedienungsanleitung Multimeter
Neueste Bedienungsanleitungen für Multimeter
Gossen Metrawatt METRAHIT IM E-DRIVE BT Bedienungsanleitung Kurth Electronic KE3500 Bedienungsanleitung Kurth Electronic KE3600 Bedienungsanleitung Klein Tools MM450 Bedienungsanleitung Klein Tools MM420 Bedienungsanleitung Klein Tools MM100 Bedienungsanleitung Klein Tools MM200 Bedienungsanleitung Klein Tools MM700 Bedienungsanleitung Klein Tools MM500 Bedienungsanleitung Klein Tools MM5000 Bedienungsanleitung