Monacor PSL-12/24 Bedienungsanleitung

Monacor Schalten PSL-12/24

Lies die bedienungsanleitung für Monacor PSL-12/24 (2 Seiten) kostenlos online; sie gehört zur Kategorie Schalten. Dieses Handbuch wurde von 19 Personen als hilfreich bewertet und erhielt im Schnitt 5.0 Sterne aus 7 Bewertungen. Hast du eine Frage zu Monacor PSL-12/24 oder möchtest du andere Nutzer dieses Produkts befragen? Stelle eine Frage

Seite 1/2
SPECIFICATION
MODELAPV-12-5APV-12-12 APV-12-15 APV-12-24
DC VOLTAGE
RATED CURRENT
CURRENT RANGE
RATED POWER
OUTPUT
LINE REGULATION
LOAD REGULATION
SETUP, RISE TIMENote.6
HOLD UPTIME (Typ.)
VOLTAGE RANGENote.4
FREQUENCY RANGE
EFFICIENCY (Typ.)
AC CURRENT
INPUT
INRUSH CURRENT(Typ.)
LEAKAGE CURRENT
SAFETY STANDARDSNote.8
WORKING TEMP.
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
MTBF
DIMENSION
OTHERS
NOTE
PACKING
OVER LOAD
OVER VOLTAGE
5V12V 15V 24V
2A 1A 0.8A0.5A
0 ~ 2A0 ~ 1A0 ~ 0.8A0 ~ 0.5A
10W 12W12W 12W
100mVp-p 120mVp-p 120mVp-p 150mVp-p
±5.0%
±1.0%
±2.0%
1500ms, 30ms / 230VAC 1500ms,30ms / 115VAC at full load
90 ~ 264VAC 127 ~ 370VDC
47 ~ 63Hz
76% 82%82% 84%
5.75 ~ 6.75V13.8 ~ 16V17.5 ~ 21V27.6 ~ 32.4V
0.2A/230VAC 0.35A/115VAC
COLD START70A(twidth=120s measured at 50% Ipeak) at 230VACμ
0.25mA/ 240VAC
Above 105% rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed
-30 ~ +70(Refer to "Derating Curve")
20 ~ 90% RH non-condensing
-40 ~ +80, 10 ~ 95% RH
± ℃0.03%/(0 ~ 50)
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X,Y, Z axes
1. All parametersNOTspecially mentioned aremeasured at230VAC input, rated load and 25of ambient temperature.
2. Ripple &noise aremeasured at20MHz of bandwidthby using a 12"twistedpair-wire terminated with a 0.1uf &47uf parallelcapacitor.
3. Tolerance: includes setuptolerance, lineregulation and load regulation.
4. Derating may be needed underlow input voltage. Please check thestaticcharacteristics for moredetails.
5.The power supply is considered as a component that will be operatedincombination withfinal equipment.SinceEMC performance will be affected by the
complete installation, thefinal equipment manufacturersmust re-qualify EMC Directive on thecomplete installation again.
6.Lengthof set up time ismeasuredat first coldstart.Turning ON/OFF the power supply may leadto increase of the set up time.
7. Theunit mightnot be suitable for lighting applications in EU countries. Please check with your localauthoritiesfor thepossible useof theunit.
8.The model certified for CCC(GB19510.14,GB19510.1, GB17743 and GB17625.1) is an optional model . Please contact MEAN WELL for details.
Protection type : Shut off o/p voltage, clamping by zener diode
12W Single Output Switching Power Supply
Constant voltage design
Universal AC input /Full range
Protections: Short circuit /Over load /Over voltage
Fully isolated plasticcase
Cooling by free airconvection
Small and compact size
Classpower unit, no FG
Class 2 power unit
ass LPSP
IP42 design
Suitable for LED relatedfixture or appliance
(such as LEDDecoration or Advertisement devices)
100% full load burn-intest
Low cost, high reliability
2 years warranty
Features :
APV-12 s e r i e s
RIPPLE & NOISE (max.)Note.2
VOLTAGE TOLERANCENote.3
ENVIRONMENT
SAFETY &
EMC
PROTECTION
20ms/230VAC 15ms/115VAC at full load
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
I/P-O/P:3.75KVAC
I/P-O/P:>100M Ohms / 500VDC / 25/ 70% RH
File Name:APV-12-SPEC 2017-11-03
EMC IMMUNITY
Compliance to EN55032,EN61000-3-2 Class A,EN61000-3-3
Compliance to EN55024,EN61000-4-2,3,4,5,6,8,11; light industry level(surge 2KV), criteriaA
EMC EMISSION
77*40*29(L*W*H)
1145.7K hrs min. MIL-HDBK-217F (25)
0.08Kg; 120pcs/11.8Kg/1.06CUFT
110 SELV
F
UL8750,CSAC22.2 No.250.0-08, ENEC42design refer to EN609501EN61347-1,EN61347-2-13,EN62384 Independent,IPApproved;-
MAX. No. of PSUs on 16A
CIRCUIT BREAKER17 units (circuit breaker of type B) / 29 units (circuit breaker of type C) at 230VAC
LPS
IP42
(optional)
IS 15885(Part 2/Sec13)
R-41027766
THOMAS SAMUELTHOMAS SAMUEL
(exceptfor 15V)

Bewerten Sie dieses Handbuch

5.0/5 (7 Bewertungen)

Produktspezifikationen

Marke: Monacor
Kategorie: Schalten
Modell: PSL-12/24

Brauchst du Hilfe?

Wenn Sie Hilfe mit Monacor PSL-12/24 benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten