Lies die bedienungsanleitung für Newland NVF260 (5 Seiten) kostenlos online; sie gehört zur Kategorie Scanner. Dieses Handbuch wurde von 22 Personen als hilfreich bewertet und erhielt im Schnitt 4.6 Sterne aus 11.5 Bewertungen. Hast du eine Frage zu Newland NVF260 oder möchtest du andere Nutzer dieses Produkts befragen? Stelle eine Frage
Seite 1/5

SCANNING MADE SIMPLE
NVF260
stationary scanner
user guide

11
Use of Programming Command
Besides the barcode programming method, the scanner can also be configured by serial commands (HEX) sent from the
host device. . All commands must be entered in uppercase letters
Command Syntax
Prefix StorageType Tag SubTag {Data} [,SubTag {Data}] [;Tag SubTag {Data}] […] Sufx
Prex 7E 01 30 30 30 30: “~ 0000” (HEX: <SOH> ) 6 characters. ,
StorageType: “ ” (HEX: ) or “#” (HEX: ), 1 character. “ ” means permanent setting which will not be lost by removing @40 23 @
power from the scanner or rebooting it; “#” means temporary setting which will be lost by removing power from the scanner
or rebooting . it
Tag: A 3-character case-sensitive eld that identies the desired command group. For example, all USB HID-KBW
conguration settings are identied with a Tag of KBW.
SubTag: A 3-character case-sensitive eld that identies the desired parameter within the tag group. For example, the
SubTag for the keyboard layout is CTY.
Data: The value for a feature or parameter setting, identied by the Tag and SubTag.
Sux: ETX>“;< ” (HEX: 3B 03) 2 characters. ,
Multiple commands can be issued within one Prefix/Sux sequence. For conguration commands, only the Tag, SubTag,
and Data elds must be repeated for each command in sequence. If an additional command is to be applied to the same
Tag, then the command is separated with a comma (,) and only the and elds of the additional commands SubTag Data
are issued. If the additional command requires a dierent eld, the command is separated from previous command by Tag
a semicolon (;).
Query Commands
For query commands, the entry in the eld in the syntax above is one of the following characters means: Data
* (HEX: 2A) What is the scanner’s current value for the setting(s).
& (HEX: ) What is the factory default value for the setting(s). 26
^ (HEX: ) What is the range of possible values for the setting(s). 5E

12
The value of the eld in a query command can be either StoreType “ ” (HEX: ) or “#” (HEX: @40 23).
A query command with the SubTag eld omitted means to query all the settings concerning a tag. For example, to query all
the current settings about Code 11, you should enter 7E 01 30 30 30 30 40 43 31 31 2A 3B 03 (i.e.
~<SOH>0000@C11*;<ETX>).
Responses
Dierent from command sequence, the prex of a response consists of the six characters of “<STX><SOH>0000” (HEX:
02 01 30 30 30 30).
The scanner responds to serial commands with one of the following three responses:
<ACK> (HEX: ) Indicates a good command which has been processed. 06
<NAK> (HEX: ) Indicates a good conguration command with its eld entry out of the allowable range for this 15 Data
Tag and SubTag combination (e.g. an entry for an inter-keystroke delay of 100 when the eld will
only allow 2 digits), or an invalid query command.
<ENQ> (HEX: ) Indicates an invalid Tag or SubTag command. 05
When responding, the scanner echoes back the command sequence with the status character above inserted directly
before each of the punctuation marks (the comma or semicolon) in the command.
Examples
Example 1: Enable Code 11, set the minimum and maximum lengths to 12 and 22 respectively.
Enter: 7E 01 30 30 30 30 40 43 31 31 45 4E 41 31 2C 4D 49 4E 31 32 2C 4D 41 58 32 32 3B 03
(~<SOH>0000@C11ENA1,MIN12,MAX22 ETX>) ;<
Response: 02 01 30 30 30 30 40 43 31 31 45 4E 41 31 06 2C 4D 49 4E 31 32 06 2C 4D 41 58 32 32 06 3B 03
(<STX><SOH>0000@C11ENA1<ACK>,MIN12<ACK>,MAX22<ACK> ETX>) ;<
Example 2 Query the current minimum and maximum lengths of Code 11. :
Enter: 7E 01 30 30 30 30 40 43 31 31 4D 49 4E 2A 2C 4D 41 58 2A 3B 03
(~<SOH>0000@C11MIN*,MAX* ETX>) ;<
Response: 02 01 30 30 30 30 40 43 31 31 4D 49 4E 31 32 06 2C 4D 41 58 32 32 06 3B 03
(<STX><SOH>0000@C11MIN12<ACK>,MAX22<ACK> ETX>) ;<
Produktspezifikationen
Marke: | Newland |
Kategorie: | Scanner |
Modell: | NVF260 |
Brauchst du Hilfe?
Wenn Sie Hilfe mit Newland NVF260 benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten
Bedienungsanleitung Scanner Newland
16 August 2024
13 Mai 2024
25 August 2023
Bedienungsanleitung Scanner
- Scan Dimension
- Elmo
- Ricoh
- Matter And Form
- CDVI
- Maginon
- Plustek
- Epson
- Martin
- Veho
- Honeywell
- Braun
- Dyka
- Medion
- Minolta
Neueste Bedienungsanleitung für -Kategorien-
14 Juni 2025
14 Juni 2025
2 Juni 2025
1 Juni 2025
30 November 2024
16 Oktober 2024
11 Oktober 2024
11 Oktober 2024
6 Oktober 2024