Lies die bedienungsanleitung für OzCharge OC-PRO600 (12 Seiten) kostenlos online; sie gehört zur Kategorie Nicht kategorisiert. Dieses Handbuch wurde von 17 Personen als hilfreich bewertet und erhielt im Schnitt 4.7 Sterne aus 9 Bewertungen. Hast du eine Frage zu OzCharge OC-PRO600 oder möchtest du andere Nutzer dieses Produkts befragen? Stelle eine Frage
Seite 1/12

OWNER’S MANUAL
Models: OC-PRO600 / OC-PRO1200
AUSTRALIAN & NEW ZEALAND STANDARD AS/NZS 60335.2.29 APPROVED

1 • Oz Charge manual www.ozcharge.com.au
Congratulations on purchasing an Oz Charge fully automatic switched mode 12 Volt battery charger,
maintainer and rejuvenator. Please take the time to carefully read and understand this manual before
using this product.
IMPORTANT SAFETY ADVICE AND WARNINGS
• The charger is designed to charge and maintain 12V conventional lead-acid batteries only.
(VRLA), AGM, CALCIUM, GEL & WET.
• Always refer to the battery manufacturers specications and recommendations if you’re
unsure of your battery charging requirements. Eg. Such as removing or not removing cell caps
whilst charging, battery type, maximum charge rate etc..
• Explosive gases may escape from the battery during charging so please ensure the battery is
charged in a well ventilated area.
• This charger is designed for indoor use only and should never be exposed to water, rain, snow,
liquids etc.
• Do not attempt to use the charger if it has been dropped or damaged.
• Do not attempt to use the charger if the cables or plugs are damaged.
• If battery acid contacts your skin or clothing, wash immediately with soap and water. If acid
enters your eye, immediately ush the eye with running cold water for at least 10 minutes and
seek medical attention. Someone should always be within range of your voice.
• Never attempt to charge a damaged battery, frozen battery or non rechargeable battery.
• Never place the charger on the battery or battery on the charger.
• When working with lead-acid batteries, remove personal metal items such as rings, bracelets,
necklaces, watches and make sure you don’t short circuit the battery terminals with any type
of metal tool or piece of jewellery as this will cause an explosion. You can wrap your spanner
with insulation tape to minimise the risk of a short circuit.
• NEVER smoke, use an open ame or create sparks near a battery or charger during charging
operation as this may cause an explosion and explosive gases.
• Do not disassemble the charger. Take it to a qualied and authorised person for repair.
• If the AC cord is damaged do not attempt to use. It must be replaced or repaired by a qualied
person.
• If using a generator, you must ensure you use a surge protector to protect the charger from
voltage spikes.
• The charger must not be used or played with by inrm persons or children. Also keep it away
from any pets.
MAIN FEATURES
• 100% automatic smart battery charger & maintainer with reconditioning.
• The battery charger is easy to use and requires no technical experience.
• Fully microprocessor controlled with safety timers at every stage.
• Battery condition analysis.
• Selectable battery type.
• Selectable charge rate / mode.
• Patented battery rejuvenation (reconditioning).

2 • Oz Charge manual www.ozcharge.com.au
• Battery voltage retention analysis.
• Pulse charge for long term maintenance.
• Ultra lower power consumption (ECO Mode)
• Multi Stage:
1 - Qualication - Battery condition check
2 - Battery rejuvenation (recondition mode)
3 - Soft start charging
4 - Bulk charging
5 - Absorption charging
6 - Equalisation charging
7 - Battery analysis
8 - Float mode
9 - Long term maintenance pulse charge
• Automatic diagnosis and charge: On power up, the charger will automatically diagnose the
battery condition and determine if the rejuvenation mode (reconditioning) or charge cycle is
required.
• Patented battery rejuvenation technology: The charger has a unique and patented reju-
venation feature which uses high voltage equalising and peak pulse reconditioning to repair
sulphated batteries. This feature is fully automatic and depends on the internal impedance of
the battery. It also depends on whether the battery is still connected in the vehicle.
• Can be left on 24/7 to ensure your battery is always maintained and fully charged: The
battery charger can be left unattended and left permanently connected all year round. The
intelligent charger will monitor the battery voltage and will maintain it at peak performance
with a special pulse charge during long term maintenance.
• Short circuit and reverse polarity protection:
• Heavy-duty and corrosion-resistant output connectors:
• Crocodile clips and ring terminals: It comes with a quick connect y lead and 2 dierent
kinds of connectors, crocodile clips and ring terminals. The ring terminals are perfect for per-
manent connection to your battery. You can connect the lead to the battery and tuck the lead
away while you are using your vehicle and when you get back to your garage simply plug the
lead back into the charger.
• Rapid Charge Mode: Uses maximum charging
current to ensure the fastest charge time. You may
hear the fan turn on during this mode.
• Silent Charge Mode: Charges at a slightly
reduced charge rate so the cooling fan is not
required.
• Maintenance Mode: Ideal and recommended for
long term maintenance charging or for charging
smaller batteries.
Note: Image shows OC-PRO600 model.
Produktspezifikationen
Marke: | OzCharge |
Kategorie: | Nicht kategorisiert |
Modell: | OC-PRO600 |
Brauchst du Hilfe?
Wenn Sie Hilfe mit OzCharge OC-PRO600 benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten
Bedienungsanleitung Nicht kategorisiert OzCharge
24 August 2024
24 August 2024
Bedienungsanleitung Nicht kategorisiert
- Sauter
- Astera
- Philos
- BenQ
- Stamm Bodyfit
- Favini
- Respironics
- Sunding
- Wire Technologies
- Soler & Palau
- Praktica
- ATAG
- Konig & Meyer
- Uniden
- Markbass
Neueste Bedienungsanleitung für -Kategorien-
18 Juni 2025
18 Juni 2025
18 Juni 2025
18 Juni 2025
18 Juni 2025
18 Juni 2025
18 Juni 2025
18 Juni 2025
18 Juni 2025
18 Juni 2025