Lies die bedienungsanleitung für PCE Instruments PCE-ALC 20 (7 Seiten) kostenlos online; sie gehört zur Kategorie Alkoholtester. Dieses Handbuch wurde von 3 Personen als hilfreich bewertet und erhielt im Schnitt 4.8 Sterne aus 2 Bewertungen. Hast du eine Frage zu PCE Instruments PCE-ALC 20 oder möchtest du andere Nutzer dieses Produkts befragen? Stelle eine Frage

Seite 1/7
User manuals in various languages (français, italiano, español, português, nederlands,
türk, polski) can be found via our product search on:
www.pce-instruments.com
PCE-ALC 20
USER MANUAL
ENGLISH
ALCOHOL-TESTER
2
Thank you for choosing PCE-ALC 20. By reading this manual, you can comprehensively understand the
features of the alcohol tester are as follows:
»Adopting a compact gas circuit design, high-precision sampling system, instrument level circuit design,
and advanced algorithms to ensure fast, accurate, and stable measurement;
»After the test results are displayed, there are green, yellow, and red indicator prompts
»Rechargeable lithium battery.
»Adopting Type-c charging interface
»Can view test records
Please pay attention to the Warning sign and warning words in this manual. „Warning“ means the
situation or action that may cause measurement deviation or damage to the instrument or components.
Please do not disassemble the instrument or components for maintenance, otherwise it may cause
damage to the instrument or other safety accidents. After a malfunction occurs, please refer it to the
manufacturer or authorized maintenance department for handling.
1 - Set up
2 - Speaker
3 - Air outlet
4 - LCD
5 - Air intake
6 - Power button
7 - Lanyard hole
8 - Charging port
INTRODUCTION
SAFETY OPERATION PRECAUTIONS
DEVICE DESCRIPTION
3
16:48
10:02
16:48
Blow
16:48
Detecting
16:48
mg/100ml
0
16:48
mg/100ml
25
16:48
mg/100ml
87
Power on and o
»Power on: In the shutdown state, long press the „power button“ to turn on the machine.
»Shutdown: In the power on state, long press the „power button“ and the screen will display „shutdown“
to shut down.
Test operation
»Press the power button to turn on the machine, and then press the power button again. The machine
displays „Please blow air before entering the blowing phase“
»Blow at the quasi air inlet, please slowly blow at a constant speed for more than 3 seconds during the
blowing phase, and the detection will be displayed result later
After testing, if the value is 0, the value display will be green. If it exceeds 20mg/100ml, the value display
will be yellow, and if it exceeds 80mg/100ml, the value display will be red.
View Records
»On the left side of the machine, slide the „Settings key“ up and down to then press the conrmation
button again to enter the view record page. Slide the „Settings key“ on the left side up and down to view
the records.
Machine Main Menu
»On the left side of the machine, slide the „Settings“ button up and down to and then press it again to
enter the main menu settings.
OPERATING INSTRUCTIONS