Lies die bedienungsanleitung für PCE Instruments PCE-BPD-P-66A (32 Seiten) kostenlos online; sie gehört zur Kategorie Messung. Dieses Handbuch wurde von 7 Personen als hilfreich bewertet und erhielt im Schnitt 4.5 Sterne aus 4 Bewertungen. Hast du eine Frage zu PCE Instruments PCE-BPD-P-66A oder möchtest du andere Nutzer dieses Produkts befragen? Stelle eine Frage
Seite 1/32

Impulse counters and ratemeters
Big panel displays with impulse counter, ratemeter and periodmeter funcons. Dierent formats avail-
able with 60 mm and 100 mm digit height, 4 and 6 digits, in red color. Sturdy metal housing, with full
IP65 protecon, designed for panel, wall or hanging mount. Versale and congurable, accepts all types
of impulse signals (NPN, PNP, Namur, TTL, inducve, mechanical, encoders, ...), provides excitaon volt
-
age to power the transducer, congurable fast access menu, ‘on power up’ funcon, password and 5
congurable brightness levels
. Universal AC and DC power. Accepts up to 3 output and control opons
(relays, analog retransmission, Modbus RTU, transistor outputs, RS-485 ASCII, ...). Conguraon from
frontal keypad or remote keypad.
BIG PANEL DISPLAYS
5534r03
User’s Manual
PCE-BPD-P
www.pce-instruments.com

2
PCE Instruments
1. Large display PCE-BPD-P
Big panel displays with impulse counter, ratemeter and periodmeter funcons
Big panel displays for long distance reading, for industrial
applicaons. Dierent formats available with 4 and 6 digits,
with 60 mm and 100 m digit height. Front keypad to access
the conguraon menu, and oponal remote keypad.
Instruments with 5 impulse counter modes (see secon
1.13.3), 2 ratemeter modes (see secon 1.13.9) and 1 peri
-
odmeter mode (see secon 1.13.9).
Highly congurable, accepts all types of sensors (NPN,
PNP, push-pull, Namur, inducve, pick-up, mechanical, TTL,
CMOS, ...) including single and bidireconal encoder signals.
Reading from 999999 to -199999 (or 9999 to -1999 for 4 digit
formats) with congurable decimal point, scalable reading
with congurable mulplier (1 to 999999) and divider factors
(1 to 999999). Includes internal pull-up and pull-down resis
-
tors, congurable trigger levels, detecon by rising or falling
edge, excitaon voltage congurable from 5 Vdc to 18 Vdc.
Output and control opons with 1, 2 and 3 relays, transis
-
tor outputs, controls for SSR relays, isolated analog outputs,
communicaons in Modbus RTU, RS-485 ASCII and RS-232.
Sturdy metal housing with full IP65 protecon. Internal
connecons by plug-in screw clamp terminals, and output
through cable glands. Housing prepared for panel, wall and
hanging mount.
• Congurable ‘Fast access’ to selected funcons with key
‘UP’ (5) (see secon 1.13.17)
• ‘On power up’ for system protecon on ‘cold’ start-up and
control of alarm status (see secon 1.13.18)
• ‘FAST’ mode for fast counter applicaons (see secon
1.13.3)
• ‘SLOW’ mode for ratemeters applicaons at low frequen
-
cies (slow applicaons) (see secon 1.13.9)
• Easy conguraon for most usual sensors at the ‘SnSr /
Auto’ menu (see secon 1.13.14)
• alarms with 1 or 2 setpoints, independent acvaon and
deacvaon delays, hysteresis, manual unlocking, ... (see
secon 1.13.15)
Mulple display lters, memory of maximum and minimum
reading, password protecon, 5 brightness levels.
1. Idenfy the instrument format (see secon 1.4)
2. Power and signal connecons
- open the instrument (see secon 1.5)
- connect the power (see secon 1.7)
- connect the signal (see secon 1.8)
- close the instrument (see secon 1.5)
3. Congure the instrument (see secon 1.13)
- select the main funcon, and the decimal point posion
(see secon 1.13.2)
- congure the main funcon selected (see secon 1.13.2)
• counter modes from secon 1.13.3
• ratemeter and periodmeter from secon 1.13.9
- congure the sensor (see secon 1.13.13)
1.1 How to use this manual
If this is the rst me you are conguring big panel display,
below are the steps to follow to install and congure the in-
strument. Read all the manual secons in order to have a
full and clear view of the characteriscs of the instrument.
Do not forget to read the installaon precauons at secon
1.17.
4. Advanced conguraon (oponal)
- congure the instrument alarms (see secon 1.13.15)
- congure the fast access (see secon 1.13.17), ‘on power
up’ (1.13.18), key ‘LE’ (1.13.19) and password (1.13.26)
5. If the instrument includes analog output or serial commu
-
nicaons
- to include an opon to an instrument see secon 1.6
- to congure an installed opon, access the opon con
-
guraon menu (see secon 1.13.30)
6. Install the instrument
- mount on panel, wall or hanging (see secon 1.16)
- adjust the brightness level according to your environmen
-
tal needs (see secon 1.13.29)
Produktspezifikationen
Marke: | PCE Instruments |
Kategorie: | Messung |
Modell: | PCE-BPD-P-66A |
Brauchst du Hilfe?
Wenn Sie Hilfe mit PCE Instruments PCE-BPD-P-66A benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten
Bedienungsanleitung Messung PCE Instruments
25 Juli 2025
25 Juli 2025
25 Juli 2025
25 Juli 2025
25 Juli 2025
25 Juli 2025
25 Juli 2025
25 Juli 2025
Bedienungsanleitung Messung
- Smart365
- Draper
- Endress+Hauser
- YSI
- Multimetrix
- AkYtec
- Daytronic
- Eastron
- Camille Bauer
- Greisinger
- Aluratek
- Bavaria By Einhell
- GW Instek
- ORNO
- Grundfos
Neueste Bedienungsanleitung für -Kategorien-
30 Juli 2025
29 Juli 2025
29 Juli 2025
29 Juli 2025
28 Juli 2025
28 Juli 2025
28 Juli 2025
28 Juli 2025
28 Juli 2025