Lies die bedienungsanleitung für Rupert Neve Designs 5052 (16 Seiten) kostenlos online; sie gehört zur Kategorie Nicht kategorisiert. Dieses Handbuch wurde von 40 Personen als hilfreich bewertet und erhielt im Schnitt 4.6 Sterne aus 20.5 Bewertungen. Hast du eine Frage zu Rupert Neve Designs 5052 oder möchtest du andere Nutzer dieses Produkts befragen? Stelle eine Frage
Seite 1/16

Serial #:
Operations Manual
5052
Mic Pre / Inductor EQ

5052 Mic Pre / Inductor EQ
Thank you for your purchase of the 5052 Mic Pre / Inductor EQ. Everyone at
Rupert Neve Designs hopes you enjoy using this tool as much as we have enjoyed
designing and building it. Please take note of the following list of safety concerns
and power requirements before the use of this product.
Safety
It’s usual to provide a list of “do’s and don’ts” under this heading but mostly these
amount to common sense issues. However here are some reminders:
Don’t operate your 5052 module in or around water! Electronic equipment and
liquids are not good friends. If any liquid is spilled such as soda, coffee, alcoholic
or other drink, the sugars and acids will have a very detrimental effect. Sugar
crystals act like little rectiers and can produce noise (crackles, etc.). SWITCH OFF
IMMEDIATELY because once current starts to ow, the mixture hardens, can get
very hot (burnt toffee!) and cause permanent and costly damage. Please contact
support as soon as possible at support@rupertneve.com for resolution.
Safety Instructions:
1) Read these instructions.
2) Keep these instructions.
3) Heed all warnings.
4) Follow all instructions.
5) Do not use this apparatus near water.
6) Clean only with dry cloth.
7) Do not block any ventilation openings. Install in accordance with the
manufacturer’s instructions.
8) Do not install near any heat source such as radiators, heat registers, stoves, or
other apparatus (including ampliers) that produce heat.
9) Do not defeat the safety purpose of the polarized or grounding-type plug. A
polarized plug has two blades with one wider than the other. A grounding type plug
has two blades and a third grounding prong. The wide blade or the third prong are
provided for your safety. If the provided plug does not t into your outlet, consult
an electrician for replacement of the obsolete outlet.
10) Protect the power cord from being walked on or pinched, particularly at plugs
convenience receptacles and the point where they exit from the apparatus.
11) Only use attachments/accessories specied by the manufacturer.
12) Unplug this apparatus during lightning storms or when unused for long periods
of time.
13) Refer all servicing to qualied service personnel. Servicing is required when the
apparatus has been damaged in any way, such as when power-supply cord or plug
is damaged, liquid has been spilled or objects have fallen into the apparatus, the
apparatus has been exposed to rain or moisture, does not operate normally, or has
been dropped.
14) Do not expose this apparatus to rain or moisture.
15) The apparatus shall be connected to a mains socket outlet with a protective
earthing connection.

5052: Front Panel
LF
PEAK
8K
16K
EQ IN
220
100
60
35
MID FREQ
MID
HI Q
LOW FREQ
3K
1.5K
700
350
200
6K
HF
MID
LF
HF
PEAK
M
ic
P
re
5052 Mic Pre/EQ
I EQnductor
MIC
LINE
36
30
24
18
12
60dB 66
60
54
48
42
20Hz 250Hz
100
MIN MAX
-15 +15
0
-15 +15
0
-15 +15
0
TEXTURE
0dB
-6 +6
TRIM
MIC GAIN
SILK
RED / BLUE
48V
HPF
TO EQ
FREQ
22
20
18
14
10
4
-2
-10
Level Meters
8 segment LED Meter for
monitoring output level
HPF
Trim
Mid Parametric
Low Frequency EQ
High Frequency Shelf / Peak
Continuously variable HPF
from 20-250Hz at 12dB /
Octave
Continuously variable +/-
6dB trim control
Selectable at 35, 60, 100, and
220 Hz. Continuous gain from -15 to
+15dB Selectable peak or shelf curves.
Selectable at 200, 350, 700,
1.5 K, 3 K, and 6 KHz. With
continuous gain from -15 to
+15dB. Selectable Hi Q.
Selectable at 8 and 16 Khz. With
continuous gain from -15 to +15dB.
Selectable peak or shelf curves
Mic Gain
66dB of gain in 6dB steps
Texture
Continuously variable
control for Silk Red & Blue.
At max setting and levels
THD is 4-5% (mostly 2nd
order)
EQ In
Engages the 3-band EQ
Mic / Line
Selects between mic and
line inputs
To EQ
Sends the Mic Pre signal
directly to the EQ
Produktspezifikationen
Marke: | Rupert Neve Designs |
Kategorie: | Nicht kategorisiert |
Modell: | 5052 |
Brauchst du Hilfe?
Wenn Sie Hilfe mit Rupert Neve Designs 5052 benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten
Bedienungsanleitung Nicht kategorisiert Rupert Neve Designs
4 September 2024
28 August 2024
22 August 2024
16 August 2024
13 August 2024
12 August 2024
9 August 2024
4 August 2024
3 August 2024
27 Juli 2024
Bedienungsanleitung Nicht kategorisiert
- Disty
- Cypress
- Hi-Fun
- Cameo
- Dorma
- HuddleCamHD
- Hedbox
- AXI
- Nintendo
- Lexar
- NuPrime
- Maxell
- HyperJuice
- Dorman
- Chauvet
Neueste Bedienungsanleitung für -Kategorien-
18 Juni 2025
18 Juni 2025
18 Juni 2025
18 Juni 2025
18 Juni 2025
18 Juni 2025
18 Juni 2025
18 Juni 2025
18 Juni 2025
18 Juni 2025