Lies die bedienungsanleitung für Salus ERT30RT (2 Seiten) kostenlos online; sie gehört zur Kategorie Thermostat. Dieses Handbuch wurde von 11 Personen als hilfreich bewertet und erhielt im Schnitt 4.7 Sterne aus 9 Bewertungen. Hast du eine Frage zu Salus ERT30RT oder möchtest du andere Nutzer dieses Produkts befragen? Stelle eine Frage
Seite 1/2

ERT30RT Triac
Digital Room Thermostat
for Underfloor Heating
with Remote/FloorInput
Product Compliance
This product complies with the essential requirements ofthe
following EC Directives:
• Electro-MagneticCompatibilityDirective 2004/108/EC
• Low Voltage Directive 2006/95/EEC
• ECMarkingDirective93/68/EEC
SAFETY INFORMATION
These instructionsareapplicable tothe Salus Controls model
stated onthe front coverof this manualonly, andmust not be
used withanyother make or model.
These instructionsare intended to apply in the United Kingdom
only, and should befollowed along with any other statutory
obligations.
Thisaccessory must be fitted by a Competent person, and
installation must comply with the guidance providedin the
currenteditions of BS7671(IEE Wiring Regulations)and Part ‘P’
of the Building Regulations. Failure to comply withthe
requirementsofthese publications could lead to prosecution.
Always isolate the AC Mains supply before opening or
removingtheunit fromthewallor wallbox.
Please leave these instructions with the end user where they
shouldbe keptina safe placeforfuture reference.
INTRODUCTION
A thermostatis adevice thatis used to switch the heating
system in yourhomeonand off as needed.It worksbysensing
the air temperature and switching on the heating when the air
temperature fallsbelowthe thermostatsetting, andswitching
it off oncethe set temperature has been reached.
The ERT30RT from Salus Controls is a stylish and accurate digital
roomthermostatthat is fittedwithalarge easyto read Liquid
CrystalDisplay(LCD). The ERT30RThasbeenspecifically
designed to be used with under floor heating systems.
Abacklight andfrost function addto thefeaturesofthe
ERT30RT.
FEATURES
• Remote/Floor temperature input
• Valve Protection
• Large, easy to read LCDwithorange Backlight
• Stylish casing
• User friendly
• Frost protection
• Reset button
• Willoperate up to 5thermal actuators
• Selectable Set Back2ºC/ 4ºC
Installation
Please read the importantsafety information atthe startofthis
manual before you begin to installthe device. The idealposition
to locate theERT30RT digitalroom thermostat isabout 1.5m
abovefloorlevel.Itshould be mounted in alocation where the
thermostat is easily accessible, reasonablylit and free from
extremes of temperature. Loosen thescrew which islocatedon
the bottom of thehousing. Open thehousing by pulling the
bottom ofthe cover then lift off.Now mount thebase plate
with thesupplied screws firmlyto thewall oronto theflush-
mounted wallbox.
ERT30RT not only works by itself, i.e. dip switchsetting, but
also canbe controlled by two controlmethods, i.e. Night
Setback by clock, and Communciation Signal from ERT52 via
communication terminal.
Theelectricalconnectionstothe ERT30RTare madeto the
internal terminal strips.Connectiondetailsareshown below-
no Earth connection is required for the correctand safe
operation of the thermostatasthe deviceis double insulated.
Terminal Connections
T erminalDescriptionTerminalBlock
Switched Output
LMains Live
NMains Neutral
Temperature setback (230V ACinput)
Terminal Description
S1Remote/Floor temperature sensor terminal 1
S2Remote/Floor temperature sensor terminal 2
R emote/FloorSensor10KNTCType
AfterinstallingtheERT30RT inasuitable location,wiring
connections canbe made asshownabove. The following criteria
applyto the installation:
•The incoming ACmainssupplyshould be 230VAC
and fused at6 Amps.
• Optimumcablesizeforinstallationis1.5squaremm;wiring
colours should be inaccordance withthe current requirements
of the IEE WiringRegulations.
•Allwiring connectionsshould be securely made, and befirmly
terminated within each of the terminal screwclamps.
Do notrestore the mainssupplyto the systemuntil allassociated
itemsare fully installed.
NOTE: Allelectrical installation workshould be carried outby a
suitablyqualifiedElectricianor othercompetentperson.Ifyou
arenot sure how to install this thermostat consult eitherwitha
qualified electrician,heating engineeroryour boiler/heating
system supplier for adviceon how tocontinue.
Donotremove or refit theERT30RT wiringwithout the
mains supplytothe systembeing isolated.
DIP SwitchSettings
Changes to the DIP Switchsettings should only be made by the
Engineer carrying outtheinstallationorAnother qualified
person. TheseDIPswitches arelocated insidetheunit. Follow
steps in the installation section on how toopenthe unit.
Theinstaller shouldselect the switchpositions required if
changes need to be made to thefactorydefault settings.
SwitchPosition Function
Sensor Mode SelectionIntR/F Int+FInt: InternalAir Sensor only (default)
R/F: Floor or Remote Sensor only
Int+F: InternalAir and Floor
Sensor mode.
SwitchPosition Function
System Cool HeatHeat– Heating Mode (default)
Cool – Will set system to
cooling mode
Set Back
TemperatureºC reduction in heat mode
2ºC 4ºC
TemperatureºC rise in cool mode
Output Control TypeOn/Off PWMPWM – PWM output(default)
On/Off-Switch toon/offmode
ValveProtection (VP)Disable VPVP - Enable (default)
Disable- Disables VP
N.B: If the SystemDIP switchisset to ‘Cool’,PWM mode is
automaticallydisabled.In this casethe ERT30RTwillonly
operate inOn-Offmode,even if the OutputControl DIP switch
is set forPWMmode.
After Installation
Aftercompleting installation and poweringup
the ERT30RT for thefirst timethe thermostat
willbehave in the following way:
Allthe indicatorson the display and the backlightwillbe turned
on for afew seconds. After a few seconds, the ERT30RT willthen
operatein Normal mode (controller output OFF), anddisplay
the current room temperature.
Allthecontroller settings willbe returned tothe valuesstored
in EEPROM. If the ResetButton ispressed,the ERT30RT will
behave inthe same wayas described above, except that any
previouslysavedusersettings will bedeletedand overwritten
with the defaultsettings.
FunctionDefault ValueEEPROM Backup
Operation ModeNormalNormal
Room Temperature22ºC, updated22ºC, updated
within a few secondswithin a few seconds
AllSet Point10ºC - 35ºCDepends on setting
T emperaturesstoredinEEPROM
Floor LimitInternalAir Sensor +Dependson setting
TemperatureFloor Sensor mode:stored in EEPROM
30ºC(heating mode)
15ºC (cooling mode)
ºC IndicatorOnDepends on setting
stored inEEPROM
Frost SettingOffDepends on setting
stored in EEPROM
Heat IndicatorHeatDepends on setting
stored in EEPROM
Output OffOff
N.B: Please be aware thatafter aReset,the ERT30RToutputmay
turn ONif the room temperature islowerthan theSet Point
temperature in heating mode.
USER INTERFACEANDCONTROLS
The statusandoperation ofthe ERT30RTcanbe clearlyseenon
the large orange backlit Liquid Crystal Display(LCD) - this display
allowstheuserto see ataglancethe currentstatusofthe
heating system.
There are few usercontrols for the ERT30RT,making the
controller very easyto operate. These controlsare shown below,
along with a description of each oftheirfunctions.
UserControlFunction Summary
Key /OperationFunctions
MINUS (-) keyDecreasesthe selected setting
PLUS (+) keyIncreasestheselected setting
RESETbuttonRestartsthe ERT30RT
Operation
As previously described, the ERT30RTis
configured and adjusted by the use of an
intuitive user interface with aminimal
number of usercontrols,and the backlit LCDgivesahighly
visible, easilyreadable indication ofthe thermostatstatus.
LCD IndicatorFunctionSummary
IndicatorSymbol Function
HEATIndicates heating modeis active
COOLIndicates cooling modeis active
CRESCENTIndicates setback temperature mode is active
TEMPERATUREIndicates either current room temperature
orset point temperature
FROSTIndicates frost protection modeis active
HEATINGIndicates heat control modeis active
Checking theSetTemperature
Pressing either the PLUS or MINUS key twice
willdisplaythe currentSet Point
temperature:
Aftera few seconds withouta key press, the ERT30RTwill return
to NORMAL mode andwilldisplay the currentroom
temperature.
Adjusting theSetPoint Temperature
AdjustingtheSetPointtemperature is
done withthe ERT30RT in NORMAL mode.
Press either thePLUS orMINUS keytwice
to enter setting mode. After doing this, the
displayed Set Point temperature will flash:
Press the PLUS or MINUS key to increase or decrease the Set
Point temperature within the range of10°C to35°C, in0.5°C
steps. The SetPoint temperaturewill stopflashing while being
adjusted, but willflash again oncethekey is released.Pressing
and holding the PLUS or MINUS key for two secondswill
increase or decrease the setting quickly.
The thermostatwillreturn to NORMAL mode aftera few
seconds if nokeyis pressed.
Frost ProtectionMode
The ERT30RThas a Frost Protectionmode,
but this isonly active whenthe thermostat
is operating in Heat mode.The Frost
Protection mode temperature ispreset at
5ºC; this temperature is factory set andcannot be adjusted.
To enable FrostProtectionpressthe PLUS andMINUS keys
together for a few seconds, thenreleasethem.The displaywill
then display the Frost Protection Set Point andFrosticon:
To disable Frost Protection and return the thermostat to
NORMAL mode,pressthe PLUS andMINUS keystogether fora
few seconds.
ModelNo: ERT30RT
Terminal
Block
AdjustingtheOffset Temperature Setting
The Offsettemperature setting can be
reviewed or adjusted by entering the Offset
Temperature Setting mode.This isdone by
pressing thePLUS and MINUSkeys together
for a few seconds. The display will change
and display ‘Set’, asshown here:
To release the keysreview the Offset
temperature, press either the PLUS or MINUS
key; the display willchange to show the
current Offset temperature:
The thermostatwillreturn to NORMAL
modeaftera few secondsifnokey is
pressed.Tochangethe Offsettemperature,
press eitherthePLUS orMINUS keyto enter
the Offsettemperature settingmode:the
displayed temperature setting will thenflash
toshow that it can bechanged:
Press the PLUSorMINUSkey to increase or decreasethe Offset
temperature within the range of – 3.5°C to + 3.5°C, in 0.5°C
steps. The Offset temperature will stop flashing while being
adjusted, but willflash again oncethekey is released.Pressing
and holding the PLUS or MINUS key for afewsecondswill
increase or decrease the setting quickly.
The thermostatwillreturn to NORMAL mode aftera few
seconds if nokey is pressed.
SettingtheFloorLimit Temperature
TheFloorLimit temperatureisactivewhentheERT30RTisset
for Internal Air Sensor + Floor Sensor operation, and can be set
intwo modes: heating or cooling.
Heating:
Changes to the settingsare madeby
pressing the PLUS and MINUS keystogether
for 7 seconds. The display willchange and
display‘HL’anda static Heatingicon,as
shown here:
Releasingthe PLUS and MINUS keyswill
thenallow the ERT30RT to change to a
flashing displayshowingthe lastor default
High Limit temperature setting:
PressthePLUS orMINUSkeytoincrease ordecreasetheHigh
Limit temperature in 0.5°C steps.The HighLimit temperature
willstop flashing while being adjusted, butwillflash againonce
the key isreleased.Pressing and holding the PLUS or MINUS key
for two seconds willincrease or decrease thesettingquickly.
The thermostatwillchange to theLow Limitsetting afterafew
seconds of no key presses, as shownhere:
The display willshow the lastor default
LowLimit temperature setting.This can be
changed inexactlythe same wayas the
High Limit setting.
The thermostatwillreturn to NORMAL mode aftera few
seconds if nokeyis pressed.
Cooling:
If the ERT30RT is set for cooling mode,
there isno HighLimitsettingto adjust.
Changesto the settings are madeby
pressing the PLUS and MINUS keystogether
for 7 seconds. The display will change and display ‘LL’ and a
static Frost icon, as shown here:
The Low Limitsettingfor Cooling canbe changedin exactly the
same way as previously described for Heating.
Floor SensorError Mode
The ERT30RT has an inbuilt sensor errormode.If the thermostat
detects afaultwith the floor sensor anerror code willbe shown
on the display. The displaywillalternate betweenthe error code
and the currentroom temperature.
Display Description
Normaloperation – room temperature displayed, backlight off
Error E1 – over floor temperature limit,backlight off
Error E2 – floor sensor opencircuit,backlightflashes
Error E3 – floor sensor shortcircuit, backlightflashes
When the sensor fault isrepaired, the thermostatwill return to
NORMAL mode and displaythe current roomtemperature.
OTHER FUNCTIONSANDCONTROLS
Backlight
The backlight of theERT30RT isswitchedonautomatically
whenever any ofthe keysare pressed. The backlightwill remain
illuminated for a few seconds after the last key press. If the
room temperatureis higherthan35°C,the backlightwillblink
onandoff;thisblinkingeffectalsohappens ifthethermostat
senses that the floor sensor is disconnected orfaulty.
The backlightwillnot illuminateif there isno mains supplyto
the controller.
Control Status
TheERT30RTindicatesonthe LCDthe controlstatusbyusinga
selectionof display icons.
HeatControl: The HEAT icon is displayedwhenever heat control
isactivated, along withananimated flame icon.
Cool Control: Theicon is displayedwhenevercool controlCOOL
is activated, along withananimated frost icon.
Reset Button
Resetsthe Thermostatto restore the setting frominternal
memory.
Setback Temperature
T heERT30RThasaprovisiontosetasetbacktemperature;
Temperature is reduced by selectable2ºC / 4ºC in heating mode;
or increased by selectable 2ºC/ 4ºCincooling mode.
TheSetback featurewill onlyoperate ifaconnection ismade
to the Setbackterminal. If the terminalstate is HIGH(above
175V AC), the Crescentindicator willbe shown onthe display,
and the Setback temperature willbe applied.
Software Protection
The ERT30RT has several protection features built in to the
software. These featuresare:
•The heat controlwillbe automatically turned offif the room
temperature is higher than35°C, or if thefloorsensor is
faulty.
•In cool mode,inbuilt short cycle protection prevents against
rapidswitching of the outputrelay: the minimumdelay
betweenthe relay being on and offis 3minutes.
•When operating in InternalAir Sensor + Floor Sensormode,
the ERT30RTwillturn offthe heatifthe floor temperature is
greater than the High Limit setting (topreventany damage
to the floor surface). Ifthe floortemperatureisbelow the
LowLimit setting, then the heat will beturnedon (tohelp
dry the floor, in for example abathroom). IftheERT30RT is
operating in cool mode,then the cooling willbeturnedoff
if the floor temperature drops below the LowLimit.
Temperaturesoutside the OperatingRange
Temperatures exceeding the measurable range willbe indicated
by ‘HI’ for temperatures above the upper limit,and ‘LO’ for
temperatures below the lower limit, as shown in the images
below:
ValveProtection Function
The Valve Protection (VP) function is providedas a way toavoid
the control valvefrom sticking orseizing when not beingused
for long periods (e.g. during the summer).
ThisfunctionisenabledbysettingtheValveProtection DIP
switch to the enable position. Whenenabled, the VP function
will turnon the thermostat outputto operate the controlvalve
fora periodof 5minuteseveryweek:theVP functionwillstill
operate evenifthe roomtemperature ishigherthan35°C,orif
the sensorsare faulty or outside ofthehigh orlowlimits.
ENERGY TIP
One way to set and use your room thermostat is to find the
lowest temperature setting thatyou arecomfortable with,and
then leave it set at this temperature.Youcan dothis by setting
the roomthermostatto alow temperature, (for example 17°C)
and thenincreasing thesettingby onedegree eachday until
you arecomfortable with theroom temperature- you won’t
have toadjust thethermostat further, asadjustment above this
setting willwaste energy: a 1°Cincrease in temperature isequal
to 3% of your heating costs.
Maintenance
The ERT30RTdigitalroom thermostatrequiresno special
maintenance. Periodically,theouter casing canbewiped clean
using a dry cloth(please DO NOTuse solvents,polishes,
detergentsor abrasive cleaners, asthese can damage the
thermostat).
There are no user serviceable partswithinthe unit; any servicing
orrepairsshould only becarriedout bySalus Controls ortheir
appointed agents.
ShouldtheERT30RT roomthermostatfailtofunction correctly,
check:
•MainssupplytotheERT30RT isswitched on.
•Heating and Cooling system is switched on.
•If the ERT30RT is stillnotfunctioningcorrectly,
press the Reset Button.
WARRANTY
Salus Controlswarrants thatthis productwill befree from any
defect in materials or workmanship, and shall perform in
accordancewith its specification, for aperiodof two years from
the dateof purchase.Salus Controls soleliability for breachof
thiswarrantywillbe (at itsoption) torepair orreplace the
defective product.
SALUS ControlsGmbH
Deutschland
Dieselstr. 34
D-63165 Mühlheim am Main
www.salus-controls.de Tel:06108825850
Product Specification
Model:ERT30RT TRIAC
Type:Non-programmable Triac version digital
room thermostat
designed for underfloor heating applications.
Switch upto 5 thermalactuators.
Operation
Control Method:
1. PWM control(default)
2. On– Offcontrol
Temperature Measurement
InternalAir Sensoror InternalRemote/Floor
Air Sensor+Floor SensorModeSensor OnlyMode
Temperature5.0ºC– 45.0ºC(internal air sensor)5.0ºC – 65.0ºC
measurement
range5.0ºC –65.0ºC
( floorsensor)
Temperature5.0ºC – 45.0ºC (internal airsensor)5.0ºC – 45.0ºC
display range
5.0ºC – 45.0ºC
( floorsensor)
Temperature 0.5ºC0.5ºC
display
resolution
Set point10.0ºC – 35.0ºC (internal airsensor)5.0ºC – 45.0ºC
temperature(Frost mode 5.0ºC)
range(Frost mode 5.0ºC)
Floor LimitHeat mode:5.0ºC– 45.0ºCNo limit setting in
temperaturethis mode
range(default 30.0ºC)
Coolmode: 5.0ºC –45.0ºC
(default 15.0ºC)
Temperature 0.5ºC0.5ºC
setting
resolution
Temperature-3.5ºC to+3.5ºCin0.5ºC steps- 3.5ºC to +3.5ºC
offsetin 0.5ºC steps
(default 0ºC)
(default 0ºC)
Memory Backup
Type: Internalmemory (EEPROM)
Switching
Switching Voltage:230V AC/50Hz
Switching Current:Switching current0.2Aresistive
IP30 Class2
Environment
Operating Temperature: 0ºCto + 40ºC
Storage Temperature:-20ºC to+60ºC
Salus Controls plc, Salus House, DodworthBusiness Park South,
Whinby Road, Dodworth, Barnsley S75 3SP
Tel: 01226323961
www.salus-tech.com
Email: tech@salus-tech.com
GB
SLGE3S2 ERT30RT Manual EN & DE:Layout 1 2/17/11 1:48 PM Page 1
Produktspezifikationen
| Marke: | Salus |
| Kategorie: | Thermostat |
| Modell: | ERT30RT |
Brauchst du Hilfe?
Wenn Sie Hilfe mit Salus ERT30RT benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten
Bedienungsanleitung Thermostat Salus
1 August 2025
31 Juli 2025
31 Juli 2025
31 Juli 2025
31 Juli 2025
25 Juli 2025
24 Juli 2025
23 Juli 2025
23 Juli 2025
23 Juli 2025
Bedienungsanleitung Thermostat
Neueste Bedienungsanleitung für -Kategorien-
19 Januar 2026
14 Januar 2026
14 Januar 2026
13 Januar 2026
2 Januar 2026
29 Dezember 2026
27 Dezember 2025
25 Dezember 2025
23 Dezember 2025
23 Dezember 2025