Lies die bedienungsanleitung für Samsung MIM-B14 (4 Seiten) kostenlos online; sie gehört zur Kategorie Nicht kategorisiert. Dieses Handbuch wurde von 39 Personen als hilfreich bewertet und erhielt im Schnitt 4.6 Sterne aus 20 Bewertungen. Hast du eine Frage zu Samsung MIM-B14 oder möchtest du andere Nutzer dieses Produkts befragen? Stelle eine Frage
Seite 1/4

English
EXTERNAL CONTROLLER INSTALLATION
Parts
PRODUCT
NAME
EXTERNAL
CONTROLLER PCB CASEHARNESS WIRESSCREW
QUANTITY1EA1EA1EA for EACH WIRE2EA
SHAPE
Installation
1. Fix PCB case() inside the indoor unit control box or at an appropriate position with screws ().
2. After fixing PCB cases, attach the external controller PCB. (See the following figure, Assembly Drawing)
3. Connect 2 pin wire () between the external controller PCB CN83 and indoor unit PCB EXT_CTRL connector(CN83).
4. Connect 4 pin wire () between the external controller PCB CN81 and indoor unit PCB COMP/ERROR
connector(CN81).
Installation option setting of indoor unit
Indoor unit with DIP S/W
Operation Specification according to Indoor Unit PCB installation option Set up
WIRE NO.OUTPUT STATE
K11 OFFK11 & K12 OFF
1,2 Error Check
3,4 COMP. CheckOperating Check
5,6 Signal Input (TIMER)
[figure, Assembly Drawing]
SCREW PCB CASE
SCREW fixing
Positions
Screw fixing positions
when necessary
WIRE
WIRE
Align the case locking with the PCB locking
Indoor unit without DIP S/W
Purpose5, 6 INPUT3, 4 OUTPUT1, 2 OUTPUT
Turn on/off the indoor unit via
external contact controlDRY CONTACTTHERMO ON/OFF or
OPERATION ON/OFF
ERROR STATUS
(Normal Close)
Control external heaterExternal heater’s Switch
Turn on/off the indoor unit via
external contact control and
control external heater
(1*)
DRY CONTACTExternal heater’s Switch
(*1) When the purpose is to use as external heater’s on/off signal, monitoring signal for external contact control will not
be outputted.
Circuit diagram of external controller’s output
For turning on/off the indoor unit via external contact control
AC LAMP
For controlling external heater (On/Off)
Circuit diagram for using external heater for the indoor units without hot water coil terminal
AC
Relay External
Heater
Detailed method about Installation option establishment
refers to Indoor Unit manual. (External contact control
setting: Refer to SGE14, SGE15 of 02 Series installation
option External heater control setting: Refer to SEG15
of 02 Series Installation Option and SEG18 of 05 Series
installation option))
Dry contact(no power source contact) must be be
connected to the input terminal 5,6.
When MIM-B14 is used for controlling external heater, its
contact should not be connected directly to the load.
(Only use as switch as shown in above diagram.)
DB98-26202A-03
SOL MIM-B14 IM-EN,TR_DB98-26202A-03_A5.indd 22-232016-06-20 오후 7:48:40
Produktspezifikationen
| Marke: | Samsung |
| Kategorie: | Nicht kategorisiert |
| Modell: | MIM-B14 |
Brauchst du Hilfe?
Wenn Sie Hilfe mit Samsung MIM-B14 benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten
Bedienungsanleitung Nicht kategorisiert Samsung
17 Januar 2026
13 Januar 2026
13 Januar 2026
11 Januar 2026
10 Januar 2026
10 Januar 2026
10 Januar 2026
6 Januar 2026
6 Januar 2026
5 Januar 2026
Bedienungsanleitung Nicht kategorisiert
Neueste Bedienungsanleitung für -Kategorien-
22 Januar 2026
22 Januar 2026
22 Januar 2026
22 Januar 2026
22 Januar 2026
22 Januar 2026
22 Januar 2026
22 Januar 2026
22 Januar 2026
22 Januar 2026