Sani-Lav 510FA Bedienungsanleitung
Sani-Lav
Spülbecken
510FA
Lies die bedienungsanleitung für Sani-Lav 510FA (6 Seiten) kostenlos online; sie gehört zur Kategorie Spülbecken. Dieses Handbuch wurde von 3 Personen als hilfreich bewertet und erhielt im Schnitt 4.6 Sterne aus 2 Bewertungen. Hast du eine Frage zu Sani-Lav 510FA oder möchtest du andere Nutzer dieses Produkts befragen? Stelle eine Frage
Seite 1/6

1
A C O R B AT T E R Y P O W E R E D
W A S H S TAT I O N W I T H E L E C T R O N I C S E N S O R
Operating Manual for 5-Person Hands-Free Floor Mount
Stainless Steel Wash Station
AC Models 510FA and 510FA-0.5
Battery Models 510FB and 510FB-0.5
of Domestic and Foreign Parts
Columbia does not recommend use with harsh chemicals.
Product Compliance
NSF/ANSI 2 Food Equipment, NSF/ANSI 372 Lead-Free Compliant, ASME A112.18.1

2
COLUMBIA SPECIFICATIONS
A C O R B AT T E R Y P O W E R E D
800.626.2117 columbiasinks.com info@columbiasinks.com
©2021 Columbia Products
W A S H S TAT I O N W I T H E L E C T R O N I C S E N S O R
Parts List
(1) Floor mount wash station
(1) Leg assembly set
(18) Nuts, bolts and washers for leg assembly
(8) Nuts and washers for connecting sink to leg assembly
(5) AC or Battery powered sensor faucet assembly
(5) Mixing check valve
(3) Strainer assembly with basket
Installation Instructions
Step 1
1. 2 and 3-Person models require leg assembly.
2. Place wash station sink on leg assembly and secure with hardware (provided).
3. Establish sink location.
4. Mark the floor where the four holes are at the base as shown in illustration A.
5. Drill holes as required for mounting hardware. (Hardware not included).
Step 2
1. Install strainer assembly.
2. Install faucets to the sink following the instructions provided with sensor unit.
3. Attach supply tube with elbow to back of faucet.
4. Install mixing check valve and compression fitting to control box of each sensor faucet.
Step 3
1. Secure wash station to floor.
2. Connect waste line to strainer assembly (s).
3. Mount sensor control boxes at desired location on wall.
4. Connect power line from sensor to control box.
5. Attach supply tube from faucet to control box.
6. Connect hot and cold water from the source to mixing check valve (s).
7. Remove aerator from the spout assemblies and flush water system. (see step 7 sensor
installation instructions)
8. Check connections for leaks.
9. Replace aerator onto the spout (s).
Step 4
1. Seal gap between bowl and leg assembly as shown in illustration B.
2. We recommend sealing top of backsplash to wall if applicable as shown in illustration C.
WARNING: This product can expose you to chemicals including Chromium (hexavalent compounds),
Lead, and Phthalates (DEHP) which are known to the State of California to cause cancer and birth defects
or other reproductive harm. For more information go to www.P65Warnings.ca.gov.
NOTE: Lead content originates from Brass components in valves and faucets and is certied under
NSF/ANSI 372 as containing less than 0.25% lead in wetted surfaces.
Notice for California Consumers
Go to for more information on replacement parts and installation videos.columbiasinks.com
Tools Required
Tape measure
Adjustable wrench
Drill motor and drill bits
Pipe wrench
Level
Safety glasses
Screw drivers: phillips and standard
Pencil
Socket wrench
Illustration A
Illustration B
Illustration C

3
COLUMBIA SPECIFICATIONS
A C O R B AT T E R Y P O W E R E D
800.626.2117 columbiasinks.com info@columbiasinks.com
©2021 Columbia Products
W A S H S TAT I O N W I T H E L E C T R O N I C S E N S O R
10”
(254mm)
8” (203mm)
Front
.875” (22mm)
dia. holes (5)
11”
(279.4mm)
19.5”
(495.3mm)
11”
(279.4mm)
19.5”
(495.3mm)
19.5”
(495.3mm)
19.5”
(495.3mm)
Hole Configurations
Side
27” (686mm)
20” (508mm)
2” (51mm)
7.5” (191mm)
45º
.75” (20mm)
.5” R
(12.7mm)
100” (2540mm)
29.75” (755.65mm) 29.75” (755.65mm)
97” (2463.8mm)
20”
(508mm)
16.5”
(407mm)
1.5”
(38mm)
2” (51mm)
1.5” (38mm)
Top
.5” R
(12.7mm)
20.25” (514.35mm)20.25” (514.35mm)
2.875”
(73.02mm)
1.5” (38mm)
35” (889mm)
floor to rim
height
mounting holes
9” (228.6mm)
on center
9”
(228.6mm)
6.75” (171mm)
10.25”
(267 mm)
2” drain hole
21” (533.4mm)36.5” (927.1mm) 36.5” (927.1mm)
Floor Mounting Detail
.5” dia. Floor
Mounting Holes
9” on Center
1.5” Leg
Thickness
.75” From
Edge of Leg
to First Hole
Produktspezifikationen
Marke: | Sani-Lav |
Kategorie: | Spülbecken |
Modell: | 510FA |
Brauchst du Hilfe?
Wenn Sie Hilfe mit Sani-Lav 510FA benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten
Bedienungsanleitung Spülbecken Sani-Lav
12 Juni 2025
12 Juni 2025
12 Juni 2025
11 Juni 2025
11 Juni 2025
11 Juni 2025
11 Juni 2025
11 Juni 2025
11 Juni 2025
11 Juni 2025
Bedienungsanleitung Spülbecken
- Leisure
- CDA
- Eagle Group
- Concept
- Cookology
- Stern-Williams
- Advance Tabco
- Artusi
- BLANCO
- Kernau
- Oliveri
- Elkay
- Gustavsberg
- Rangemaster
- Teka
Neueste Bedienungsanleitung für -Kategorien-
12 Juni 2025
12 Juni 2025
11 Juni 2025
11 Juni 2025
11 Juni 2025
11 Juni 2025
11 Juni 2025
11 Juni 2025
11 Juni 2025
11 Juni 2025