Lies die bedienungsanleitung für Sani-Lav 5A1F-0.5 (5 Seiten) kostenlos online; sie gehört zur Kategorie Spülbecken. Dieses Handbuch wurde von 2 Personen als hilfreich bewertet und erhielt im Schnitt 4.3 Sterne aus 1.5 Bewertungen. Hast du eine Frage zu Sani-Lav 5A1F-0.5 oder möchtest du andere Nutzer dieses Produkts befragen? Stelle eine Frage
Seite 1/5

WALL MOUNT WASH STATION
1
Operating Manual for 1-Person Wall Mount Stainless Steel Wash Station
Models 5A1F 5A1F-0.5
of Domestic and Foreign Parts
Columbia does not recommend use with harsh chemicals.
Product Compliance
NSF/ANSI 2 Food Equipment, NSF/ANSI 61, Section 9, ASME A112.18.1/CSA B125.1, ADA Compliant
ADA Compliant

Illustration A
Illustration B
Illustration C
800.626.2117 columbiasinks.com info@columbiasinks.com
©2023 Columbia Products
COLUMBIA SPECIFIC ATIONS
WALL MOUNT WASH STATION
2
Installation Instructions
Step 1
1. Establish sink location on the wall.
2. Measure a recommended 45” from finished floor and draw a level line which will be the top edge
of the wall mounting bracket.
3. Hold the wall mounting bracket against the wall and mark the wall where the holes are. Drill holes
and secure bracket to the wall as shown in illustration A. Screws are not provided.
Step 2
1. Install faucet to the sink using faucet mounting kit provided. We recommend using pipe thread
sealant instead of Teflon tape.
2. Install strainer assembly to the drain hole.
3. Connect hot and cold water supply lines (not included) to the back of faucets.
Step 3
1. Position sink onto the wall bracket.
2. Mount support bracket to the bottom of the sink. Do not tighten.
3. Slide or push support brackets against the wall and mark holes for fastening. See illustration B.
4. Remove support brackets from the sink and drill holes for fastening.
5. Install fastening hardware to the drilled holes. (not included)
6. Mount support bracket to the bottom of the sink and fasten them to the wall.
Step 4
1. Install valves onto the sink.
2. Install elbow fittings to Knee Pedal Valves.
3. Connect hot and cold connecting tubes from the spouts to valves.
Step 5
1. Connect waste line or drain pipe to the strainer assembly.
2. Connect hot and cold water supply line to the water source.
Step 6
1. Remove aerator from the spout assembly and flush water system. Check connections for leaks.
Replace aerator onto the spout assembly.
2. We recommend sealing top of backsplash to wall as shown in illustration C.
Parts List
(1) Wall mount wash station
(1) 8” on center faucet
(1) Faucet mounting kit
(1) Wall-mounting bracket
(2) Support brackets
(4) Support bracket mounting bolts and washers
(1) Strainer assembly with basket
Trouble Shooting Guide
Problem Possible Cause To Diagnose Remedy
Water drips from
the spout or from
under the lever.
1. Seat washer is worn
2. Seat is worn
3. O-rings are worn
Shut cold water source off. See if
water still leaks from the spout. If
leaks continues repair hot side if
not repair cold side.
Recommend
installing hot
or cold faucet
repair kit.
Tools Required
Tape measure
Adjustable wrench
Drill motor and drill bits
Pipe wrench
Level
Safety glasses
Screw drivers: phillips and standard
Pencil
Socket wrench
WARNING: This product can expose you to chemicals including Chromium (hexavalent compounds),
Lead, and Phthalates (DEHP) which are known to the State of California to cause cancer and birth defects
or other reproductive harm. For more information go to www.P65Warnings.ca.gov.
NOTE: Lead content originates from Brass components in valves and faucets and is certied under
NSF/ANSI 372 as containing less than 0.25% lead in wetted surfaces.
Notice for California Consumers
Go to for more information on replacement parts and installation videos.columbiasinks.com

Wall-mounting bracket
10” (254mm)
10” (254mm)
45º
35” (889mm)
suggested
floor to rim
height
Front
Side
29” (736.6mm)
20” (508mm)
2” (51mm)
1.5” (38mm)
7.5”
(191mm)
.5” R (12.7mm)
5” (127mm)
.437” (6mm)
.75” (19mm) slot
.437” (6mm)
dia. hole
7” (177.8mm)
16.75”
(425.45 mm)
2”
(51mm)
.875”
(22.22mm)
Back
Splash
.375”
dia. hole
Wall Mounting Detail
30” (762mm)
15” (381mm) 15” (381mm)
20”
(508mm)
18”
(457.2mm)
1.5” (38mm)
2” (51mm)
Top
1.5” (38mm)
27” (685.8mm)
2” drain hole
(50.8mm)
.5” R
(12.7mm)
Cross-breaks to aid drainage
11” (279.54mm)
Back Splash
Supply Line Detail
1/2” Male NPT
Hot
from Wall
Cold
from Wall
.875” (22mm)
dia. holes (2)
Hole Configurations
11”
(279.4mm)
11”
(279.4mm)
8”
(203.2mm)
6” (152.4mm)
800.626.2117 columbiasinks.com info@columbiasinks.com
©2023 Columbia Products
COLUMBIA SPECIFIC ATIONS
WALL MOUNT WASH STATION
3
Produktspezifikationen
Marke: | Sani-Lav |
Kategorie: | Spülbecken |
Modell: | 5A1F-0.5 |
Brauchst du Hilfe?
Wenn Sie Hilfe mit Sani-Lav 5A1F-0.5 benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten
Bedienungsanleitung Spülbecken Sani-Lav
21 August 2025
21 August 2025
21 August 2025
21 August 2025
21 August 2025
21 August 2025
21 August 2025
21 August 2025
21 August 2025
21 August 2025
Bedienungsanleitung Spülbecken
- Atosa
- Franke
- Gustavsberg
- Krowne
- Artusi
- The Galley
- Teka
- Schock
- Smeg
- Sloan
- Elkay
- Deante
- Tot Mate
- Signature Hardware
- Oliveri
Neueste Bedienungsanleitung für -Kategorien-
21 August 2025
21 August 2025
21 August 2025
21 August 2025
21 August 2025
21 August 2025
21 August 2025
21 August 2025
20 August 2025
20 August 2025