Lies die bedienungsanleitung für Saxon 8710P3 (4 Seiten) kostenlos online; sie gehört zur Kategorie Wetterstation. Dieses Handbuch wurde von 16 Personen als hilfreich bewertet und erhielt im Schnitt 4.8 Sterne aus 8.5 Bewertungen. Hast du eine Frage zu Saxon 8710P3 oder möchtest du andere Nutzer dieses Produkts befragen? Stelle eine Frage
Seite 1/4

1
Operation Instruction
Ⅰ. Main Functions:
1. Weather forecast for 5 states: sunny, semi-sunny, cloudy, rainy, cloudburst.
2. Time display (displaying month, date, day, hour, minute, second)
3. Indication of the trend of air pressure/temperature/humidity
4. Indication of the comfort index: dry, comfortable and wet.
5. Air pressure record of 12-hour
6. Units of air pressure for choice: mb/hpa, or inHg.
7. Calculation of sunrise and sunset time of 160 cities in Europe.
8. The indoor/outdoor temperature/humidity and Max/Min record.
9. Temperature alert.
10. Dual alarms.
11. Sunrise and Sunset display
12. Time display format for choice:12/24 hour.
13. Temperature display format for choice: ℃/℉.
14. Moon phase calculated.
Ⅱ. Power-On or Reset
1. When Power-On or reset, LCD full displays for 3 seconds, and after a “Beep” it begins testing indoor temperature, humidity and air
pressure.
2. The calendar defaults 0:00:00 January 1, 2007
3. Alarm defaults 0:00.
4. The weather icon defaults semi-sunny.
Ⅲ. Instruction of operating the KEYS
1. Key functions
Twelve functional keys: DOWN,UP, ALARM,TIME SET,LOCATION,SNOOZE,HISTORY,▲,
▼,ALERT,MAX/MIN,CHANNEL.
TIME SET
ALARM
UP
DOWN
SNOOZE
LOCATI
ON
Standard mode
Click
-----
Time
displaying /
alarm1/
Alarm2
------
Alarm on/off
-----
----
Hold
Enter into
time setting
Enter into
alarm setting
-----
-------
-----
Enter 160
cities set
Time set
Click
Confirm
the setting
-----
One step
forward
One step
backward
-----
-----
Hold
-----
-----
8steps/seco
nd forward
8steps/second
backward
-----
-----
Alarm set
Click
-----
Confirm the
setting
One step
forward
One step
backward
-----
-----
Hold
-----
-----
8steps/seco
nd forward
8steps/second
backward
-----
-----
City set
Click
-----
-----
One step
forward
One step
backward
-----
Confirm
the setting
Hold
-----
-----
8steps/seco
nd forward
8steps/second
backward
-----
-----
Channel
Alert
▲
▼
MAX/MIN
HISTORY
Standard
mode
Click
Exit RF
receiving
state/shift
channel
All the
MAX/MIN
temperature alert
on/off
Shift Hpa/inHg
°C/°F switchable
Showing the
Max value
----
Function
Operation
Function
Operation

2
Hold
Enter into
RF
registering
state
Enter into
temperature alert
setting
-----
-----
Enter into
snooze state
Enter 160
cities set
Temperature set
Click
Choose the
channel
need to be
set
Confirm the
setting
One step
forward
One step
backward
-----
-----
Hold
-----
-----
8 steps/second
forward
8steps/second
backward
-----
-----
Height
set
Click
-----
-----
One step
forward
One step
backward
-----
-----
Hold
-----
-----
8steps/second
forward
8steps/second
backward
-----
-----
TIME SET Key:
Hold “TIME SET” key for 2 seconds to enter into time setting mode, the sections being set will flash in the frequency of 1 Hz/second,
press “UP” or “DOWN”to choose the value needed then press “TIME SET” key to confirm the setting.
It will return to standard mode automatically, if there is no operation for more than 7 seconds.
ALARM Key
Click “Alarm” key to display alarm time, press once to display AL1; twice for Al2; thrice to return to standard state. Hold “Alarm” key
for 2 seconds to enter alarm setting, the sequence: AL1/ AL2 Hour Minute Exit.
It will return to standard mode automatically, if there is no operation for more than 7 seconds.
UP Key
Under setting mode, click “UP” Key to adjust one step (forward), holding the “UP” Key for 2 seconds to enter speedy adjusting mode (8
steps/seconds).
DOWN Key
Under setting mode, click “DOWN” Key to adjust one step (backward), holding the “DOWN” Key for 2 seconds to enter speedy
adjusting mode (8 steps/seconds).
Under standard mode, Click “DOWN” Key to turn alarm on/off, the setting sequence: AL1 on/ AL2 off AL2 on/ AL1 off AL1,
AL2 on AL1, AL2 off.
SNOOZE Key
When the alarm is ringing, click “SNOOZE” key to pause the alarm, and enter 5 minutes of snooze function.
LOCATION Key
Under standard mode, hold the “LOCATION” key for 2 seconds to enter city setting.
Under city setting state, hold “UP” or “DOWN” key to choose the city, and then click “LOCATION” key to confirm the setting and exit
the state.
CHANNEL Key
Under standard mode, click “Channel” key to shift RF channel, CH1CH2 CH3displaying circularly.
Under standard mode, hold “Channel” Key for 2 seconds to clean out RF registering state, temperature displays and MAX/MIN value.
Under Alert setting channel state, choose the needed setting channel..
MAX/MIN Key
Click “Max/Min” key to display MAX value of indoor/outdoor temperature, humidity for 5 seconds. Click once again to display the
MIN values for 5 seconds, click again to return to standard mode.
When it displays the Max or Min values, hold Max/Min key for 2 seconds to clear out the memory of the Max/Min values, then return to
normal standard state.
ALERT Key
Under standard mode, click Alert key to turn temperature alert on/off.
Under standard mode, hold Alert key for 2 seconds, it will enter temperature alert setting.
3
Under temperature alert setting mode, click Alert key to confirm the setting items, the sequence: channelsetting the Maxsetting the
Min.
▲Key
Under standard mode, click ▲ to choose the unit of air pressure: Hpa/Mb or inHg.
Under setting mode, click once to go forward one step/second, hold for 2 seconds to go forward 8 steps/second.
▼Key
Under standard mode, click to choose the unit of temperature between °C/°F.
Under setting mode, click to go backward one step, hold for 2 seconds to go backward 8 steps/second.
HISTORY Key
Under standard mode, clicking to check the air pressure record of past 12 hours.
RF Receiving Mode
1. After power-on and finishing testing temperature, humidity and air pressure, it enters RCC receiving state for 3 minutes. Under
standard mode, hold CH key for 3 seconds to enter RF receiving mode. If there is no new effective signal from sensors in 60 minutes,
the outdoor temperature of that CH will display “----”.
2. The outdoor temperature will display valid value of that CH from “----” when the main unit detects and receives the correct signal
from that CH again.
3. Hold “CHANNEL”, it displays CH1-->CH2-->CH3-->auto recycling (5 seconds a shift).
TIME MODE
1. The default time after power-on is 2007.1.1, 0:00:00, the range of perpetual calendar 2000-2099.
2. Under standard mode, hold “TIME SET” key for 2 seconds to enter time setting mode.
3. Under setting mode, press “UP” or “DOWN” key to adjust the data of items to be set, click “TIME SET” to confirm the data.
4. Under setting mode, the items being set will flash in the frequency of 2Hz/second, the setting sequence: year monthdate
language12/24HRhour minutetime zoneexit.
5. If there is no valid operation on the key after 7 seconds, it will exist the setting mode, but the items set will be kept. The valid keys
include “TIME SET”, “UP”, “DOWN”.
ALARM ALERT MODE
1. Under standard mode, click “ALARM” to view the Alarm time, the sequence: AL1, AL2, Normal.
2. Under standard mode, click “UP” key to switch the alarm ON/OFF, the sequence: AL1 ON, AL2 OFFAL1 OFF, AL2 ONAL1
ON, AL2 ONAL1 OFF, AL2 OFF.
3. Under ALARM time displaying mode, hold “ALARM” key for 2 seconds to enter ALARM setting mode.The setting sequence:
AL1/AL2hour settingminute settingexist setting mode.
4. During the setting, click “UP” or “DOWN” key to adjust the items to be set, and click “ALARM” key to confirm the items.
5. If there is no effective operation on the key after 8 seconds, it will exit the setting mode, but the items set will be kept. The effective
keys include “ALARM”, “UP”, “DOWN”.
6. Alarm ringing for 2 minutes totally ,and Alarming format::
(1) 0~10 seconds: one Beep/second;
(2) 10~20 seconds: two Beeps/second;
(3) 20~30 seconds, three Beeps/second;
(4) After 30 seconds, Beeping continuously.
The alarm is switched on after set.
CITY SETTING
1. Under standard mode, hold “LOCATION” key for 2 seconds to enter location setting and choose the city you stay (there are 160
European cities for selection).
2. Click “UP” or “DOWN” to choose, and click “LOCATION” key to confirm.
SUNRISE / SUNSET , MOON PHASE AND TIDE
1. The unit will calculate automatically the time of sunrise/sunset of the city everyday after the city is selected.
2. It will calculate moon phase and tide ebb/ flux every day according to the calendar. There are 8 states of moon phase and 3
step(H,M,L) of tide in all
THERMOMETER AND HYGROMETER
1. The indoor temperature range: 0°C-50°C (32°F-122°F), and the outdoor temperature range: -50°C-70°C (-58°F-158°F).
2. Humidity range: 20%-95%.
AIR PRESSURE AND WEATHER REPORT MODE
Produktspezifikationen
Marke: | Saxon |
Kategorie: | Wetterstation |
Modell: | 8710P3 |
Brauchst du Hilfe?
Wenn Sie Hilfe mit Saxon 8710P3 benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten
Bedienungsanleitung Wetterstation Saxon
27 August 2024
27 August 2024
9 Juli 2024
3 Mai 2023
Bedienungsanleitung Wetterstation
- Telefunken
- Vitek
- Prologue
- Gira
- Elro
- EVE
- Uzoli
- Johnson
- Davis
- Alecto
- La Crosse
- Trotec
- Vimar
- PeakTech
- Ventus
Neueste Bedienungsanleitung für -Kategorien-
15 Juni 2025
14 Juni 2025
13 Juni 2025
13 Juni 2025
12 Juni 2025
11 Juni 2025
11 Juni 2025
11 Juni 2025
11 Juni 2025
11 Juni 2025