Schneider A9A15215 Bedienungsanleitung
Seiten 1 Engels Nicht kategorisiert
Lies die Bedienungsanleitung für Schneider A9A15215 kostenlos online oder lade das PDF herunter. 19 Personen fanden diese Anleitung hilfreich. Frage zu diesem Modell? Stelle eine Frage

S1B8489701-00
05-2012
Transformer - iTR
A9A15215
NOTICE
ABSENCE DE TENSION SECONDAIRE
b Durant l’exploitation, en cas d'absence de basse tension
en aval du transformateur (tension secondaire), ouvrir
le disjoncteur en amont du transformateur iTR pendant
une durée minimum de 5 minutes.
Le non-respect de ces instructions provoquera une absence
de tension secondaire pendant une durée indéterminée.
ABSENCE OF SECONDARY VOLTAGE
b During use, in the absence of low voltage downstream of
the transformer (secondary voltage), open the circuit breaker
upstream of the iTR transformer for a period of at least
5 minutes.
Failure to follow these instructions will result in absence of
secondary voltage that could last indefinitely.
AUSENCIA DE TENSIÓN SECUNDARIA
b Durante la explotación, en caso de ausencia de baja tensión
abajo del transformador (tensión secundaria), abrir el disyuntor
aguas arriba del transformador iTR durante un mínimo de 5 minutos.
Si no se respetan estas instrucciones, puede producirse
una ausencia de tensión secundaria durante un tiempo
indeterminado.
AVIS
MANCANZA DI TENSIONE SECONDARIA
b Durante il funzionamento, in caso di mancanza di bassa
tensione a valle del trasformatore (tensione secondaria), aprire
l'interruttore a monte del trasformatore iTR per almeno 5 minuti.
Il mancato rispetto di queste istruzioni provoca una
mancanza di tensione secondaria per un tempo
indeterminato.
AVISO
FEHLEN DER SEKUNDÄRSPANNUNG
b Fehlt während der Versorgung die Niederspannung vor dem
Transformator (Sekundärspannung), öffnen Sie den
vorgeschalteten Leistungsschalter iTR für mindestens fünf Minuten.
Die Nichtbeachtung dieser Anweisungen kann zu einem
Fehlen der Sekundärspannung über einen unbestimmten
Zeitraum führen.
AVVISO
HINWEIS
1
2
NOTICE
ABSENCE OF SECONDARY VOLTAGE
b During use, in the absence of low voltage downstream of
the transformer (secondary voltage), open the circuit breaker
upstream of the iTR transformer for a period of at least
5 minutes.
Failure to follow these instructions will result in absence of
secondary voltage that could last indefinitely.
NOTICE
ABSENCE
OF SECONDARY VOLTAGE
b
During use, in the abs enc e of low v oltage
dow
nstr
eam
of
th
e transforme
r (sec on
d
ary voltage), open the circu it break er
upstr
eam of the iTR trans
fo rmer for a perio d of at least
5 m in
utes.
Failure
to follow thes
e instru
ctions will result in absence of
se
conda
ry volta
ge that
could las t inde
finitely.
1 7
4 68
12 Va
24 Va
230 Va
PRI
SEC
Power
Puissance
Potencia
Potenza
Leistung
Nominal secondary voltage
Tension nominale secondaire
Tensión nominal secundaria
Tensione nominale secondaria
Sekundäre Nennspannung
No-load voltage
Tension à vide
Tensión en vacío
Tensione a vuoto
Leerlaufspannung
A9A15215 25 VA12 V16 Va a
24 V32 Va a
Produktspezifikationen
| Marke: | Schneider |
| Kategorie: | Nicht kategorisiert |
| Modell: | A9A15215 |
Brauchst du Hilfe?
Wenn Sie Hilfe mit Schneider A9A15215 benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten
Bedienungsanleitung Nicht kategorisiert Schneider
Schneider CCT15338 Bedienungsanleitung Schneider CCT15553 Bedienungsanleitung Schneider Modicon TM3 Bedienungsanleitung Schneider CCT5015-0002 Bedienungsanleitung Schneider MTN629993 Bedienungsanleitung Schneider MTN649202 Bedienungsanleitung Schneider MTN6003-0005 Bedienungsanleitung Schneider XALK178W3B140E Bedienungsanleitung
Beliebt in Nicht kategorisiert
Schneider EVlink Wallbox Plus EVH3S3P04K Bedienungsanleitung Schneider MTN6705-0008 Bedienungsanleitung Schneider MTN6921-0001 Bedienungsanleitung