E2002, Shure Incorporated
MODEL MX400 SERIES MICROPHONES
OVERVIEW
Shure MicroflexrMX400 Series microphones are miniature
gooseneck-mounted electret condenser microphones de-
signed primarily for speech and vocal pickup. They can be
mounted on lecterns, pulpits, or conference tables. All models
include a preamplifier and are available with interchangeable
cardioid, supercardioid, or omnidirectional cartridges.
FEATURES
SWide dynamic range and frequencyresponse for
accurate sound reproduction across the audio spectrum
SInterchangeable cartridges provide the right polar pattern
for every application
SBalanced, transformerless output for increased immunity
to noise over long cable runs
SShock mount that provides over 20 dB isolation from
surface vibration noise
SLocking flange mount for permanently securing
microphone to lecterns, pulpits, or conference tables
SSnap-fit foam windscreen
MODEL VARIATIONS
SMX412: 305 mm (12 in.) gooseneck microphone.
SMX418: 457 mm (18 in.) gooseneck microphone.
SMX412S: 305 mm (12 in) gooseneck microphone;
includes a mute switch and an LED.
SMX418S: 457 mm (18 in) gooseneck microphone;
includes a mute switch and an LED.
SPECIFICATIONS
Frequency Response (Figure 1)
50 to 17,000 Hz
Polar Pattern (Figure 2)
Output Impedance (at 1000 Hz)
Rated at 150 Ω (180 Ω actual)
Open Circuit Sensitivity (at 1 kHz, ref. 1 V/Pascal*)
Cardioid: –35.0 dB (17.8 mV)
Supercardioid: –33.5 dB (21.1 mV)
Omnidirectional:–27.5 dB (42.2 mV)
All settings –12 dB at 0 gain
*1 Pascal = 94 dB SPL
Maximum SPL (1 kHz at 1% THD, 1 kΩ load)
Cardioid: 124.2 dB
Supercardioid: 122.7 dB
Omnidirectional:116.7 dB
All settings +6 dB at 0 gain
Equivalent Output Noise (A-weighted)
Cardioid: 28.0 dB SPL
Supercardioid:26.5 dB SPL
Omnidirectional:20.5 dB SPL
Signal to Noise Ratio (referenced at 94 dB SPL)
Cardioid: 66.0 dB
Supercardioid:67.5 dB
Omnidirectional: 73.5 dB
Dynamic Range at 1 kΩ Load
96.2 dB
100 dB at 0 gain
Common Mode Rejection
45.0 dB minimum
Mute Switch Attenuation (switched models only)
50.0 dB minimum
Preamplifier Output Clipping Level (1% THD)
–6.0 dBV (0.5 V)
–12 dB at 0 gain
Polarity
Positive sound pressure on diaphragm produces positive
voltage on pin 2 relative to pin 3 of output connector.
Power Requirements
11 to 52 Vdc phantom, 2.0 mA
Environmental Requirements
Operating Temperature Range: –18°° °C to 57 C (0 F to
135 F)°
Relative Humidity: 0 to 95%
Dimensions (Figure 3)
Model MX400 Series Microphones
Specification Sheet
Produktspezifikationen
| Marke: | Shure |
| Kategorie: | Mikrofon |
| Modell: | MX412 |
Brauchst du Hilfe?
Wenn Sie Hilfe mit Shure MX412 benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten
Bedienungsanleitung Mikrofon Shure
Shure BLX4 Bedienungsanleitung Shure FP5 Bedienungsanleitung Shure WCM16 Bedienungsanleitung Shure PGA98D-98D Bedienungsanleitung Shure BLX188 Bedienungsanleitung Shure BLX2/PG58 Bedienungsanleitung Shure SLXD14 Bedienungsanleitung Shure SLXD24D/B58 Bedienungsanleitung
Alle Shure Mikrofon Bedienungsanleitungen
Beliebt in Mikrofon
Bedienungsanleitung Mikrofon
Neueste Bedienungsanleitungen für Mikrofon
Comica BoomX-D UC2 Bedienungsanleitung Devine WMD-24 Pro Duo Bedienungsanleitung Sony ECM-88BPT Bedienungsanleitung Gemini VHF-01HL Bedienungsanleitung Gemini UHF-04M Bedienungsanleitung Gemini UHF-01M Bedienungsanleitung Gemini UHF-02HL Bedienungsanleitung Gemini UHF-01HL Bedienungsanleitung Gemini VHF-02HL-S26 Bedienungsanleitung Karma MW 541 Bedienungsanleitung