Sonel CMP-1015-PV Bedienungsanleitung


Lies die bedienungsanleitung für Sonel CMP-1015-PV (3 Seiten) kostenlos online; sie gehört zur Kategorie Nicht kategorisiert. Dieses Handbuch wurde von 23 Personen als hilfreich bewertet und erhielt im Schnitt 4.7 Sterne aus 12 Bewertungen. Hast du eine Frage zu Sonel CMP-1015-PV oder möchtest du andere Nutzer dieses Produkts befragen? Stelle eine Frage

Seite 1/3
page 1 / 3 sonel.com
Digital clamp meter for photovoltaic installations
CMP-1015-PV
index: WMGBCMP1015PV
Robust design
With the help of the latest tech-
nologies, a compact instrument
for working in the toughest con-
ditions has been created. The rub-
ber housing protects the device
against accidental damage.
Visibility in any conditions
Working in full sun is not difcult
thanks to the high-brightness dis-
play. Darkness in the workplace is
not a problem thanks to the built-
in flashlight.
Multifunctional
The device is versatile due to many
measurement options. In addition
to the basic measurements, the
instrument has a recorder with
graphs, as well as special func-
tions, including inrush current (IN-
RUSH), AC and DC voltage com-
ponents, low-impedance voltage
measurement (Low Z).
Modern clamp
The innovative shape means
easier access in hard to reach
and tight places, as the basis for
mounting special voltage adapt-
ers. The clamp edging is equipped
with a contactless voltage indica-
tor sensor.
Photovoltaics under
close control
The device is dedicated to mea-
sure DC current and voltage in
photovoltaic installations with
voltages of 1500 V. The meter
also provides precise measure-
ments downstream of frequen-
cy converters thanks to the VFD
function.
Wireless communication
Transfer measurement data via
Bluetooth, in “live mode and
from internal memory to the So-
nel Multimeter Mobile applica-
tion. This allows to record and
store the results and include addi-
tional description or photos. You
can also share measurement data
as an e-mail attachment.
measurement of
PV installations
Voltage measurement up to
3000 V DC
The AHV-3 adapter is used to
measure high DC voltages (up
to 3000 V DC) in collaboration
with a master meter.
page 2 / 3 sonel.com
m.v. - measured value
Technical specications
Measurement functions Range Resolution Accuracy
±(% m.v. + digits)
AC current up to 1000 A from 0.01 A ±(2.5% m.v. + 5 digits)
DC current up to 1000 A from 0.01 A ±(2.0% m.v. + 8 digits)
AC voltage up to 1000 V from 0.001 mV from ±(1.2% m.v. + 5 digits)
DC voltage up to 1500 V from 0.1 mV from ±(0.5% m.v. + 5 digits)
AC+DC voltage up to 1000 V from 0.001 V from ±(1.5% m.v. + 20 digits)
Low Z (AC / DC voltage) up to 1000 V from 0.001 V ±(3.0% m.v. + 40 digits)
Low Z AC+DC up to 1000 V from 0.001 V ±(3.5% m.v. + 40 digits)
Resistance up to 60.00 MΩ from 0.1 Ω from ±(0.8% m.v. + 5 digits)
Frequency up to 10.00 MHz from 0.01 Hz ±(0.2% m.v. + 5 digits)
Capacitance up to 100.0 mF from 0.01 nF from ±(3.0% m.v. + 8 digits)
Duty cycle (%) 10.0…90.0% 0.1% ±(1.2% m.v. + 8 digits)
Temperature measurement -40.0…+1000ºC
-40.0…+1832ºF
0.1ºC
0.1ºF
±(1.5% m.v. + 3ºC)
±(1.0% m.v. + 5.4ºF)
Continuity / Diode test ✓ ✓ /
Basic features
HOLD
Automatic range selection
Advanced features
Current and voltage measurements downstream
the inverter, frequency converter or in the
VFDsystem
High voltage DC measurement (HVDC)
Inrush current
Non-contact voltage detector
MIN / MAX ✓ ✓ /
PEAK HOLD
Relative measurement REL
TRMS measurement
Memory : :
internal measurements: 128 results
recorder: 16 recordings, 100 000 points, sampling frequency: from 1 Hz
external in mobile application
Bluetooth communication
Other features
Auto-off
Battery indication
Integrated flashlight
Beeper
Display
Type graphical LCD
Display backlight
Safety and conditions for use
Measuring category (EN 61010) CAT IV 600 V
CAT III 1000 V
Ingress protection IP40
Dimensions 273 x 96 x 48 mm 10.7” x 3.8” x 1.9”|
Operating temperature 5...40ºC 41...104°F|
Storage temperature -20…+60ºC -4...140°F|
page 3 / 3 sonel.com
Li-Pol 7.4 V
1200mAh
rechargeable
battery
WAAKU30
Charger
WAZASZ25
Battery charger
power supply
WAZASZ26
Carrying case
WAWALM3
Set of test leads
CAT IV, M
WAPRZCMP2
AC-16 line splitter
(facilitates current
measurements)
WAADAAC16
Temperature
measurement
probe (K-type, bayonet)
WASONTEMP
probe (K-type, metal)
WASONTEMK2
Crocodile clip mini,
1 kV 10A (set)
WAKROKPL10MINI
Set of test leads
CAT IV, S
WAPRZCMM1
Factory calibra-
tion certicate
Calibration cer-
ticate with
accreditation
M13 carrying case
WAFUTM13
Test lead with probe
for CMM/CMP (set)
WAPRZCMP1
Test lead 2 m
with 10 A fuse
CATIV 1000 V
black / blue / green
/ red / yellow
WAPRZ002BLBBF10
WAPRZ002BUBBF10
WAPRZ002GRBBF10
WAPRZ002REBBF10
WAPRZ002YEBBF10
Pin probe (banana
socket) red / blue
/ yellow / black
B1 / black B3
WASONREOGB1
WASONBUOGB1
WASONYEOGB1
WASONBLOGB1
WASONBLOGB3
Crocodile clip
red / blue / yel-
low / black
WAKRORE20K02
WAKROBU20K02
WAKROYE20K02
WAKROBL20K01
+
Temperature
measurement
Probe (K-type)
WASONTEMK
Adapter
WAADATEMK
Set of test leads
CAT IV, M
WAPRZCMM2
Standard accessories
Optional accessories
AHV-3
voltage
adapter
WAADAAHV3
Mounting adapter
for AHV-3
WAPOZUCH13
+


Produktspezifikationen

Marke: Sonel
Kategorie: Nicht kategorisiert
Modell: CMP-1015-PV

Brauchst du Hilfe?

Wenn Sie Hilfe mit Sonel CMP-1015-PV benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten