TDE Instruments Digalox DPM72-AVP Bedienungsanleitung
TDE Instruments
Messgeräte
Digalox DPM72-AVP
Lies die bedienungsanleitung für TDE Instruments Digalox DPM72-AVP (8 Seiten) kostenlos online; sie gehört zur Kategorie Messgeräte. Dieses Handbuch wurde von 18 Personen als hilfreich bewertet und erhielt im Schnitt 4.8 Sterne aus 9.5 Bewertungen. Hast du eine Frage zu TDE Instruments Digalox DPM72-AVP oder möchtest du andere Nutzer dieses Produkts befragen? Stelle eine Frage
Seite 1/8

Digalox DPM72-AVP
Instruct
Visit www.digalox.com
to dow
Package contents:
Panel me
1. Intended Use
• Indoor use non
condens
• Panel mounting.
•
Failure to comply with th
•
Preferred supply of USB
Supply via USB in opera
2. Safety instructions
•
Note: the measuremen
voltages!
• When working on the
d
the device!
•
The device must not be
shutdown.
•
Read instruction manual
•
The device is not intende
devices must be used to
• When
connecting switch
whose isolation voltage
i
voltage. For example,
wh
least 500V.
• Do not open the
housing
• Do not use
the instrumen
• All cables
carrying hazar
separators.
----- ----- 1
tion manual
(Rev-2015-04)
wnload
software “Digalox
Manager”
ter Digalox DPM72,
5x jumpers, 1
x
ing
, non corrosive.
ese instructions will
void
all guaran
devices via scre
w terminals with 1
ation, USB supply voltage must be a
t inputs of the device can carry l
device
hazardous voltages must
e used as the only protective dev
carefully before operating the devi
ed to protect persons or facilities ag
gua
rantee safety (prote
ction relais
es
to the terminals J1-J6 only
switc
s at least
twice the
maximum occu
hen measuring
250V AC switch
mu
g!
nt
in the presence of explosive or
fla
rdous
voltages must be secured
wit
”
.
x
mounting bracket
tee and warranty.
0 to
24V AC/DC.
at least 5V
ife
-threatening
not be connected
to
vice or protective
ce!
gainst harm. Specific
, off
-switches, etc).
ches must
be used
rring
measurement
ust be isolated
for at
ammable substances!
th external

----- ----- 2
3. Description
The measure modes volt AC/DC, ampere, frequency and 5A current transformer
are supported. Scale endpoint of the indicator as well as scaling of the analogue
signal and current transformer measurement can be adjusted freely via the DIP
switch, alternatively there is an option for automatic adaption of the scale endpoint.
The unit can be switched between volt and ampere measurement via an external
switch. Minimum and maximum values are recorded and can be displayed
optionally using an external switch. Measured values are recorded over a time
span of 3 minutes up to 14 days. The time base as well as the display of the
measuring history can be activated by an external switch.
The following parameters can be adjusted using the USB-Software: Scale-
endpoint, scale-caption, display-style (pointer, tachometer, bar graph, and more),
splash display, thresholds for alarm output, hysteresis, and more. Recorded
measurement values can be read and a continuous transmission of the actual
measuring value can be enabled. Using the software, values can be viewed and
exported as CSV.
Front
1 Unit or free text
2 Threshold value
3 Upper scale caption
4 Graphical measurement display
5 Digital measurement value
6 Lower scale caption
Back
1 2 optocoupler switch outputs
2 DIP switch for setting measurement
mode and upper scale caption
3 Supply voltage input
4 Jumpers for configuration or connection
external switch for activating/switching
measurement mode, graphical historic
data display, min/max display, auto-
scaling
5 USB interface for alternative power
supply and software communication
interface
6 Measurement inputs

----- ----- 3
4. Electrical Connections
The device may only be operated in one of the connection options shown below.
Warning:
Voltage measurement on the high
side (between plus and load) is
recommended only for voltages up
to 50V!
In this case the entire device is on
high potential. Particularly to be
considered when connecting
switches to JP1-6.
DPM72 AV/P
Voltage and current
direct measurement
I
low
I
high
U
high
U
low
U
s
U
s
Load
+/L -/N
max.
10A
Measurement inputs
10-24V
Supply
Fuse 250mA
max.
500V
DPM72 AVP only!
Voltage and current direct
measurement, high side
I
low
I
high
U
high
U
low
Load
+/L -/N
Measurement inputs
AVP
only!
max.
50V!
U
s
U
s
10-24V
Supply
Fuse 250mA
DPM72 AV/P
Voltage direct, current via
current transformer
Ilow Ihigh Uhigh Ulow
Load
+/L -/N
Current
transformer
Measurement inputs
max.
500V
UsUs
10-24V
Supply
Fuse 250mA
Produktspezifikationen
Marke: | TDE Instruments |
Kategorie: | Messgeräte |
Modell: | Digalox DPM72-AVP |
Brauchst du Hilfe?
Wenn Sie Hilfe mit TDE Instruments Digalox DPM72-AVP benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten
Bedienungsanleitung Messgeräte TDE Instruments
21 August 2024
21 August 2024
18 August 2024
18 August 2024
Bedienungsanleitung Messgeräte
- Owon
- Blebox
- Brüder Mannesmann
- Myoton
- Hama
- Enda
- Maximum
- Sonel
- Stabila
- Honeywell
- Ansmann
- Psiber
- Weltron
- Uni-Trend
- H-Tronic
Neueste Bedienungsanleitung für -Kategorien-
16 Oktober 2024
16 Oktober 2024
16 Oktober 2024
16 Oktober 2024
16 Oktober 2024
16 Oktober 2024
16 Oktober 2024
16 Oktober 2024
16 Oktober 2024
16 Oktober 2024