Testec TT-SI 7002 Bedienungsanleitung
Testec
Nicht kategorisiert
TT-SI 7002
Lies die bedienungsanleitung für Testec TT-SI 7002 (12 Seiten) kostenlos online; sie gehört zur Kategorie Nicht kategorisiert. Dieses Handbuch wurde von 12 Personen als hilfreich bewertet und erhielt im Schnitt 4.3 Sterne aus 6.5 Bewertungen. Hast du eine Frage zu Testec TT-SI 7002 oder möchtest du andere Nutzer dieses Produkts befragen? Stelle eine Frage
Seite 1/12

INSTRUCTION MANUAL
TT-SI 7002
25MHz active differential probe
x20 / x50 /x200


Man_7002_0919 www.testec.de 1
Safety Summary
To avoid personal injury and/or product damage, review and comply
with the following safety precautions. These precautions apply to both operating and
maintenance personnel and must be followed during all phases of operation, service,
and repair of this probe.
A
WARNING
statement calls attention to an operating procedure, practice,
or condition, which, if not followed correctly, could result in injury or death to
personnel.
A
CAUTION
statement calls attention to an operating procedure, practice, or
condition, which, if not followed correctly, could result in damage to or destruction
of parts or the entire product.
Do Not Work Alone
Do not work alone when working with high voltages.
Inspect the Probe
Inspect the probe and accessories for cracks and frayed or broken leads before each
use. If defects or damages are noted, DO NOT USE the probe.
Dry Conditions
Hands, shoes, floor, and work bench must be dry. Avoid making
measurements under humidity, dampness, or other environmental conditions
that might affect safety.
Do Not Remove the Probe’s Casing
Removal of the probe’s casing may expose you to electric shock. If necessary,
disconnect the inputs and outputs of the probe before opening the case.
Hazardous Contact
To avoid injury, remove jewelry such as rings, watches, and other metallic objects. Do
not touch exposed connections and components when power is present.
Unexpected Charges
Hazardous voltages may be present in unexpected locations in circuitry being
tested when a fault condition in the circuit exists.
Capacitors inside the instrument may retain a charge even if the instrument is
disconnected from its source of supply.
Use Only in Office-Type Indoor Setting
The probe is designed to be used in office-type indoor environments.
Do not operate the probe:
•
In the presence of noxious, corrosive, flammable fumes, gases, vapors,
chemicals, or finely-divided particulates.
•
In environments where there is a danger of any liquid
spilled
on the probe.
•
In air temperatures exceeding the specified operating
temperatures.
•
In atmospheric pressures outside the specified altitude limits or
where the
surrounding gas is not air.
Produktspezifikationen
Marke: | Testec |
Kategorie: | Nicht kategorisiert |
Modell: | TT-SI 7002 |
Brauchst du Hilfe?
Wenn Sie Hilfe mit Testec TT-SI 7002 benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten
Bedienungsanleitung Nicht kategorisiert Testec
28 August 2024
28 August 2024
28 August 2024
28 August 2024
28 August 2024
28 August 2024
28 August 2024
19 August 2024
16 Mai 2024
25 April 2024
Bedienungsanleitung Nicht kategorisiert
- Globalo
- Wachendorff
- Tiger
- GR Bass
- REL Acoustics
- Milectric
- Logicom
- Nexcom
- Kernau
- Maul
- Scytek
- Swissvoice
- Saint Algue
- PSSO
- Motu
Neueste Bedienungsanleitung für -Kategorien-
16 Juni 2025
16 Juni 2025
16 Juni 2025
16 Juni 2025
16 Juni 2025
16 Juni 2025
16 Juni 2025
16 Juni 2025
16 Juni 2025
16 Juni 2025