Texas Instruments LOG112 Bedienungsanleitung


Lies die bedienungsanleitung für Texas Instruments LOG112 (25 Seiten) kostenlos online; sie gehört zur Kategorie Nicht kategorisiert. Dieses Handbuch wurde von 2 Personen als hilfreich bewertet und erhielt im Schnitt 4.6 Sterne aus 3 Bewertungen. Hast du eine Frage zu Texas Instruments LOG112 oder möchtest du andere Nutzer dieses Produkts befragen? Stelle eine Frage

Seite 1/25
LOG112
LOG2112
SBOS246D – JUNE 2002 – REVISED APRIL 2005
www.ti.com
DESCRIPTION
The LOG112 and LOG2112 are versatile integrated circuits
that compute the logarithm or log ratio of an input current
relative to a reference current. V
LOGOUT
of the LOG112 and
LOG2112 are trimmed to 0.5V per decade of input current,
ensuring high precision over a wide dynamic range of input
signals.
The LOG112 and LOG2112 features a 2.5V voltage refer-
ence that may be used to generate a precision current
reference using an external resistor.
Low DC offset voltage and temperature drift allow accurate
measurement of low-level signals over the specified tem-
perature range of –5°C to +75°C.
FEATURES
EASY-TO-USE COMPLETE FUNCTION
OUTPUT SCALING AMPLIFIER
ON-CHIP 2.5V VOLTAGE REFERENCE
HIGH ACCURACY: 0.2% FSO Over 5 Decades
WIDE INPUT DYNAMIC RANGE:
7.5 Decades, 100pA to 3.5mA
LOW QUIESCENT CURRENT: 1.75mA
WIDE SUPPLY RANGE:
±4.5V to ±18V
PACKAGES: SO-14 (narrow) and SO-16
PRODUCTION DATA information is current as of publication date.
Products conform to specifications per the terms of Texas Instruments
standard warranty. Production processing does not necessarily include
testing of all parameters.
Copyright © 2002-2005, Texas Instruments Incorporated
Precision
LOGARITHMIC AND LOG RATIO AMPLIFIERS
Please be aware that an important notice concerning availability, standard warranty, and use in critical applications of
Texas Instruments semiconductor products and disclaimers thereto appears at the end of this data sheet.
APPLICATIONS
LOG, LOG RATIO:
Communication, Analytical, Medical, Industrial,
Test, General Instrumentation
PHOTODIODE SIGNAL COMPRESSION AMP
ANALOG SIGNAL COMPRESSION IN FRONT
OF ANALOG-TO-DIGITAL (A/D) CONVERTER
ABSORBANCE MEASUREMENT
OPTICAL DENSITY MEASUREMENT
L
O
G
1
1
2
L
O
G
2
1
1
2
A
2
A
1
Q
1
Q
2
C
C
I
1
V
REF GND
NOTE: Internal resistors are used to compensate gain change over temperature.
The V
CM
pin is internally connected to GND in the LOG2112.
V
O3
V+
GND
LOG112
V
LOGOUT
= (0.5V)LOG (I
1
/I
2
)
V
O3
= K (0.5V)LOG (I
1
/I
2
), K = 1 + R
2
/R
1
A
3
R
2
R
1
V
REF
R
REF
+IN3
V
LOGOUT
IN3
V
V
CM
I
2
V
REF
All trademarks are the property of their respective owners.

Bewerten Sie dieses Handbuch

4.6/5 (3 Bewertungen)

Produktspezifikationen

Marke: Texas Instruments
Kategorie: Nicht kategorisiert
Modell: LOG112

Brauchst du Hilfe?

Wenn Sie Hilfe mit Texas Instruments LOG112 benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten