Lies die bedienungsanleitung für Tripp Lite SmartPro (48 Seiten) kostenlos online; sie gehört zur Kategorie UPS. Dieses Handbuch wurde von 30 Personen als hilfreich bewertet und erhielt im Schnitt 4.3 Sterne aus 15.5 Bewertungen. Hast du eine Frage zu Tripp Lite SmartPro oder möchtest du andere Nutzer dieses Produkts befragen? Stelle eine Frage
Seite 1/48

1
Owner’s Manual
Smart and OmniSmart®
Medical-Grade UPS Systems
Models:
OMNISMART350HG
(Series Number: AGOM350KSR57HG)
Important Safety Instructions 2
Package Contents 5
Quick Installation 6
Basic Operation 8
Guidance and Manufacturer’s Declaration 14
Storage & Service 15
Regulatory Compliance & 16
Product Registration
Español 17
Français 33
1111 W. 35th Street, Chicago, IL 60609 USA • www.tripplite.com/support
Copyright © 2015 Tripp Lite. All rights reserved.
SMART700HG
(Series Number: AGSM700PSR3HG)
SMART1200XLHG
(Series Number: AGSM1200PSR3HG)
PROTECT YOUR INVESTMENT!
Register your product for quicker service
and ultimate peace of mind.
You could also win an
ISOBAR6ULTRA surge protector—
a $100 value!
www.tripplite.com/warranty
15-11-178-9332C2.indb 1 12/4/2015 9:20:10 AM

2
Important Safety Instructions
SAVE THESE INSTRUCTIONS
This manual contains instructions and warnings that should be followed during the installation,
operation and storage of all Tripp Lite UPS Systems. Failure to heed these warnings may affect
your warranty.
Statement of Intended Use
Tripp Lite Medical-Grade UPS Systems are intended to support and protect non-medical and
medical computer equipment and medical devices that require leakage current reduction, surge
protection, voltage regulation, line noise filtering and battery backup during power outages and
generator testing, both inside and outside patient care areas. Tripp Lite’s Medical-Grade UPS
Systems come with hospital-grade plugs and receptacles that reduce leakage to below 100μA.
Product Information
AGOM350KSR57HG AGSM700PSR3HG AGSM1200PSR3HG
AC Input Voltage 120 120 120
AC Input Voltage Range 83–147 81–143 81–143
Input Amp(s) 2.3 5.5 9.2
Output Amps(s) 1.9 5.8 6.25
Rated Power (VA/Watts) 330VA/225W 700VA/450W 1000VA/750W
Frequency 50/60 Hz 50/60 Hz 50/60 Hz
No. of Phases Single Single Single
Class Type Class I Class I Class I
Plug/Connector Type NEMA 5-15P NEMA 5-15P NEMA 5-15P
Operation Continuous Continuous Continuous
AC Input Protection (Qty./type/rating) Input breaker
(2 x 3.5A), thermal
Input breaker
(2 x 10A), thermal
Input breaker
(2 x 15A), thermal
Max Leakage Current (uA) Less than 100uA Less than 100uA Less than 100uA
Weight 25.0 lbs 44.2 lbs 46.4 lbs
Known Contraindication None None None
UPS Location Warnings
Relevant Symbols
Denotes that information in the manual should be reviewed before use.
Used to signal a warning that a statement is particularly important and could pose a safety
risk.
Warning-Dangerous Voltage No sitting
Denotes general warning sign No stepping on surface
Refer to Instruction Manual/Booklet No pushing
15-11-178-9332C2.indb 2 12/4/2015 9:20:10 AM

3
Important Safety Instructions continued
• Do not use this equipment within oxygen-enriched atmospheres, or within 0.3 m (1 ft.) of a point
at which an oxygen-enriched atmosphere is intentionally vented.
• Use caution when lifting UPS. Because of the considerable weight of all UPS systems, at least
two people should assist in lifting and installing them.
• Install your UPS indoors, away from excess moisture or heat, dust or direct sunlight.
• For best performance, the UPS should be used in a location that meets the following conditions:
Temperature: 0 to 40° C (32 to 104° F); Humidity: 0 to 95% (non-condensing);
Elevation: <6,562 ft. (2,000 m) above sea level; Pressure: >95kPa
• Leave adequate space around all sides of the UPS for proper ventilation. Do not obstruct its vents
or fan openings.
• Do not mount unit with its front or rear panel facing down (at any angle). Mounting in this manner
will seriously inhibit the unit’s internal cooling, eventually causing product damage not covered
under warranty.
• UPS is not intended for patient contact. Avoid installation that will cause accidental contact of
patients.
UPS Connection Warnings
• The UPS contains its own energy source (battery). The output terminals may be live even when
the UPS is not connected to an AC supply.
• Connect your UPS to a properly grounded AC power outlet. Do not modify the UPS’s plug in a
way that would eliminate the UPS’s connection to ground. Do not use adapters that eliminate the
UPS’s connection to ground.
• Do not plug your UPS into itself; this will damage the UPS and void your warranty.
• If you are connecting your UPS to a motor-powered AC generator, the generator must provide
filtered, frequency-regulated output.
• To remove the UPS from the supply mains, the plug serves as a disconnect device.
• Once connected, do not limit access to the input plug. The plug must be accessible to be used as
a means of disconnection.
• When connecting your UPS to the power outlet, ensure that the power outlet is provided with
suitable overcurrent protection in accordance with your national and local electrical codes. Ensure
that the overcurrent protection has a minimum of 1500A breaking capacity.
CAUTION: Do not remove cover for 5 minutes after disconnecting all sources of
supply. Risk of electric shock—hazardous live parts inside. Do not remove cover.
No user serviceable parts inside. Refer servicing to qualified service personnel.
This UPS receives power from more DC sources; disconnection of the AC and DC
source is required to de-energize the unit before servicing.
CAUTION: To ensure proper grounding with supply mains power, the input cord must
be connected with an approved country-specific plug with a protective earth ground
connection.
CAUTION: If this product is operated on battery (not connected to mains power),
adequate safeguards should be employed to protect against accidental contact
with AC power conductors.
CAUTION: Do not exceed total rated output.
WARNING: No modification of this equipment is allowed.
15-11-178-9332C2.indb 3 12/4/2015 9:20:10 AM
Produktspezifikationen
Marke: | Tripp Lite |
Kategorie: | UPS |
Modell: | SmartPro |
Brauchst du Hilfe?
Wenn Sie Hilfe mit Tripp Lite SmartPro benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten
Bedienungsanleitung UPS Tripp Lite
9 Oktober 2024
9 Oktober 2024
4 Oktober 2024
2 Oktober 2024
29 September 2024
19 September 2024
10 September 2024
8 September 2024
30 August 2024
16 August 2024
Bedienungsanleitung UPS
- Salicru
- Riello
- Avocent
- Vanson
- HP
- Liebert
- Furman
- Phoenix Contact
- Murr Elektronik
- GYS
- Minuteman
- Puls Dimension
- FSP/Fortron
- Atlantis Land
- Online USV
Neueste Bedienungsanleitung für -Kategorien-
13 Oktober 2024
13 Oktober 2024
13 Oktober 2024
13 Oktober 2024
13 Oktober 2024
13 Oktober 2024
13 Oktober 2024
13 Oktober 2024
11 Oktober 2024
5 Oktober 2024