Lies die bedienungsanleitung für TrueLife Care T3 (41 Seiten) kostenlos online; sie gehört zur Kategorie Thermometer. Dieses Handbuch wurde von 38 Personen als hilfreich bewertet und erhielt im Schnitt 4.7 Sterne aus 19.5 Bewertungen. Hast du eine Frage zu TrueLife Care T3 oder möchtest du andere Nutzer dieses Produkts befragen? Stelle eine Frage
Seite 1/41

CARE T3
EN – INSTRUCTION MANUAL
DE – ANLEITUNG
CS – NÁVOD
SK – NÁVOD
PL – INSTRUKCJA
HU – HASZNÁLATI UTASÍTÁS
SL – NAVODILA
HR – UPUTSTVO


3
Taking a reading:
1. Clean the tip with a damp cloth.
2. Turn on the thermometer by pressing the .power button
3. Three colours (green/orange/red) will ash in sequence on the thermometer, followed by the last reading
taken, the selected mode (orL / udr / rct / bth), then three dashes ( - - - ) and the measurement icon indica-
ting that the thermometer is now ready for use.
4. Place the thermometer in the chosen place – the dashes on the display will start to move and the measu-
rement icon in the right corner will begin to ash, indicating that the thermometer has successfully
started taking a reading.
5. The thermometer will complete predictive measurement after approx. 5 seconds, emitting an audible signal
(5 beeps for about 5 seconds) and lighting up the display in the corresponding colour. The measurement icon
will also stop ashing. At this point, it is possible to stop but if you want the temperature reading to be as
accurate as possible, follow the points below.
6. Next the thermometer will start the precision measurement phase.
7. Keep the thermometer in place and wait.
8. After a few minutes (depending on the measurement site), a second, longer audible signal will sound
(10 beeps for about 10 seconds) and the measurement icon will disappear.
9. The display will then show the precise measured value.
10. After taking a reading, turn o the thermometer by pressing the . Alternatively, it will switch power button
itself o after 10 minutes to save battery.
COLOURED BACKLIGHT
The thermometer also indicates the measured temperature using the coloured backlight of the display.
Temperature up to 37.2 °C (98.96 °F) – green backlight (normal body temperature)
Temperature from 37.3 to 37.7 °C (from 99.14 to 99.86 °F) – orange backlight (elevated temperature)
Temperature 37.8 °C (100.04 °F) and above – red light (fever) + audible fever alert
SELECTING THE MEASUREMENT MODE
The thermometer allows you to measure the temperature in three places on the body and the temperature of
water. To achieve the most accurate results, set the thermometer‘s measurement mode for the specic site you
are taking the reading from. To select the mode, proceed as follows:
1. Turn on the thermometer by pressing the .power button
2. When the currently selected mode appears on the display, press and hold the for about 3 sepower button -
conds until the display ashes.
3. Now you can toggle between modes, by pressing the .power button
4. After choosing the mode, simply wait until the display stops ashing and the thermometer will display
3 dashes ( - - - ) and the measurement icon indicating the thermometer is ready to take a reading.
5. Take a temperature reading.
orL – Oral mode – for measuring the temperature from the mouth
udr – Underarm mode – for measuring the temperature from the armpit
rct – Rectal mode – for measuring the temperature from the rectum
bth – Bath mode – for measuring water temperature
MEASUREMENTS IN INDIVIDUAL MODES
1. Oral mode
a. Before using the thermometer, do not eat or drink anything
(especially hot and cold food or drinks) and keep your mouth
closed for 3–10 minutes before starting the measurement.
b. Place the thermometer in your mouth under your tongue in one
of the two pockets to the left or right of the root of the tongue.
c. Close your mouth and try to breathe evenly through your nose
during the measurement (so that the reading is not aected by
airow).
Produktspezifikationen
Marke: | TrueLife |
Kategorie: | Thermometer |
Modell: | Care T3 |
Wasserfest: | Ja |
Breite: | 143 mm |
Tiefe: | 25 mm |
Gewicht: | 21 g |
Produktfarbe: | Green, White |
Steuerung: | Tasten |
Akku-/Batterietyp: | CR2032 |
Höhe: | 14 mm |
Betriebstemperatur: | 5 - 40 °C |
Display-Hintergrundbeleuchtung: | Ja |
Typ: | Kontakt-Thermometer |
Automatische Abschaltung: | Ja |
Menge pro Packung: | 1 Stück(e) |
Temperaturbereich bei Lagerung: | -10 - 50 °C |
Anzahl unterstützter Akkus/Batterien: | 1 |
Speicherkapazität: | 10 Eintragungen |
Warnanzeige bei geringem Ladestand: | Ja |
Speicherfunktion: | Ja |
Maßeinheit: | °C, °F |
Genauigkeit: | 0.1 °C |
Temperaturmessbereich: | 32 - 43.9 °C |
Position des Thermometers: | Oral, Rectal, Underarm |
Messzeit: | 10 s |
Hochtemperatur-Alarmeinstellung: | Ja |
Aufbewahrungsbox: | Ja |
Flexible Spitze: | Ja |
Brauchst du Hilfe?
Wenn Sie Hilfe mit TrueLife Care T3 benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten
Bedienungsanleitung Thermometer TrueLife
24 August 2024
17 August 2024
10 August 2024
7 August 2024
30 Januar 2024
22 September 2023
Bedienungsanleitung Thermometer
- CDN
- Sauter
- Elta
- Knikker
- Hartmann
- SOENS
- Livoo
- NEO Tools
- Bioland
- Abus
- Fluke
- Bintoi
- Dittmann
- AnD
- Respekta
Neueste Bedienungsanleitung für -Kategorien-
30 Juli 2025
29 Juli 2025
29 Juli 2025
29 Juli 2025
29 Juli 2025
28 Juli 2025
28 Juli 2025
28 Juli 2025